Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible

被引:19
|
作者
Wada, Keizo [1 ]
Mikami, Hiroshi [2 ]
Hamada, Daisuke [1 ]
Yonezu, Hiroshi [2 ]
Oba, Koichi [2 ]
Sairyo, Koichi [1 ]
机构
[1] Univ Tokushima, Inst Hlth Biosci, Dept Orthoped, Grad Sch, 3-18-15 Kuramoto, Tokushima 7708503, Japan
[2] Yoshinogawa Med Ctr, Dept Orthopaed Surg, 132-113 Kamojima Chiejima, Yoshinogawa, Tokushima 7760014, Japan
关键词
Navigation system; Total knee arthroplasty; Rotational kinematics; Reliability study; Intra-class correlation coefficients; KINEMATIC EVALUATION; DIFFERENCE; RELIABILITY; PROTOCOL; OUTCOMES;
D O I
10.1007/s00402-015-2402-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Intraoperative kinematic analysis using a navigation system in total knee arthroplasty (TKA) has been increasing. The purpose of the present study was to assess the reproducibility of the intraoperative kinematics analysis in TKA using the image-free knee navigation system. Fifty-one knees in 45 patients who received TKA, performed by a single surgeon (the senior consultant) with the resident, were included in this retrospective study. There were 7 men and 38 women and the mean age was 74.3 years. Cruciate retaining (CR) type and posterior stabilized (PS) type implants were inserted into 38 and 13 knees. The senior consultant and the resident analyzed initial kinematics, the axial rotation of the tibia and the coronal alignment of the lower limb, three times in each knee on manual passive knee flexion intraoperatively using the navigation system. Intra-class correlation coefficients (ICC) with 95 % confidence intervals were calculated to determine the reproducibility of this analysis. In regard to intra-rater reproducibility with axial rotation of the tibia, the ICC of the senior consultant was 0.965 for CR knees and 0.972 for PS knees while the ICC of the resident were 0.966 and 0.956. Inter-rater reproducibility was excellent for both knee types (ICC, 0.885 for CR knees and 0.864 for PS knees). In regard to intra-rater reproducibility with coronal alignment of the lower limb, ICC of the senior consultant was 0.990 for CR knees and 0.996 for PS knees while those of the resident were 0.990 and 0.995. Inter-rater reproducibility was also excellent for both knee types (ICC, 0.978 for CR knees and 0.994 for PS knees). Manual intraoperative kinematic analysis using a navigation system in TKA showed excellent reproducibility. This result may encourage further studies about intraoperative kinematic analysis using a navigation system in TKA.
引用
收藏
页码:271 / 276
页数:6
相关论文
共 50 条
  • [1] Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
    Keizo Wada
    Hiroshi Mikami
    Daisuke Hamada
    Hiroshi Yonezu
    Koichi Oba
    Koichi Sairyo
    [J]. Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 271 - 276
  • [2] Navigation improves accuracy of rotational alignment in total knee arthroplasty
    Stöckl, B
    Nogler, M
    Rosiek, R
    Fischer, M
    Krismer, M
    Kessler, O
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 180 - 186
  • [3] Computer assisted navigation in total knee arthroplasty - Improved coronal alignment
    Kim, SJ
    MacDonald, M
    Hernandez, J
    Wixson, RL
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 123 - 131
  • [4] Imageless Navigation System Does Not Improve Component Rotational Alignment in Total Knee Arthroplasty
    Cheng, Tao
    Zhang, Guoyou
    Zhang, Xianlong
    [J]. JOURNAL OF SURGICAL RESEARCH, 2011, 171 (02) : 590 - 600
  • [5] Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation
    Restrepo, Camilo
    Hozacic, William J.
    Orozco, Fabio
    Parvizi, Javad
    [J]. COMPUTER AIDED SURGERY, 2008, 13 (03) : 167 - 172
  • [6] Rotational alignment in total knee arthroplasty
    Cho, Yool
    Lee, Myung Chul
    [J]. ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2014, 1 (04): : 113 - 118
  • [7] Coronal alignment after total knee arthroplasty
    Lording, Timothy
    Lustig, Sebastien
    Neyret, Philippe
    [J]. EFORT OPEN REVIEWS, 2016, 1 (01): : 12 - 17
  • [8] Coronal alignment in total knee arthroplasty: a review
    F. Matassi
    F. Pettinari
    F. Frasconà
    M. Innocenti
    R. Civinini
    [J]. Journal of Orthopaedics and Traumatology, 24
  • [9] Coronal alignment in total knee arthroplasty: a review
    Matassi, F.
    Pettinari, F.
    Frascona, F.
    Innocenti, M.
    Civinini, R.
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 24 (01)
  • [10] How Accurate is Intraoperative Alignment Measurement with a Navigation System in Primary Total Knee Arthroplasty?
    Feichtinger, Xaver
    Kolbitsch, Paul
    Kocijan, Roland
    Baierl, Andreas
    Giurea, Alexander
    [J]. JOURNAL OF KNEE SURGERY, 2018, 31 (05) : 467 - 471