Imageless Navigation System Does Not Improve Component Rotational Alignment in Total Knee Arthroplasty

被引:54
|
作者
Cheng, Tao [1 ]
Zhang, Guoyou [2 ,3 ]
Zhang, Xianlong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Dept Orthopaed Surg, Shanghai Peoples Hosp 6, Shanghai 200233, Peoples R China
[2] Wenzhou Med Coll, Dept Hand & Plast Surg, Affiliated Hosp 2, Wenzhou, Zhejiang, Peoples R China
[3] Univ Lubeck, Dept Dermatol, Univ Hosp Schleswig Holstein, Lubeck, Germany
关键词
computer-navigated; navigation; image-free; total knee replacement; TKR; systematic review; meta-analysis; COMPUTER-ASSISTED NAVIGATION; CONVENTIONAL TECHNIQUE; TIBIAL COMPONENT; FOLLOW-UP; POSTOPERATIVE ALIGNMENT; KINEMATIC NAVIGATION; MANUAL IMPLANTATION; CORONAL ALIGNMENT; BLOOD-LOSS; REPLACEMENT;
D O I
10.1016/j.jss.2010.05.006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The aim of computer-assisted surgery is to improve accuracy and limit the range of surgical variability. However, a worldwide debate exists regarding the importance and usefulness of computer-assisted navigation for total knee arthroplasty (TKA). The main purpose of this study is to summarize and compare the radiographic outcomes of TKA performed using imageless computer-assisted navigation compared with conventional techniques. Materials and Methods. An electronic search of PubMed, EMBASE, Web of Science, and Cochrane library databases was made, in addition to manual search of major orthopedic journals. A meta-analysis of 29 quasi-randomized/randomized controlled trials (quasi-RCTs/RCTs) and 11 prospective comparative studies was conducted through a random effects model. Additional a priori sources of clinical heterogeneity were evaluated by subgroup analysis with regard to radiographic methods. Results. When the outlier cut-off value of lower limb axis was defined as +/- 2 degrees or +/- 3 degrees from the neutral, the postoperative full-length radiographs demonstrated that the risk ratio was 0.54 or 0.39, respectively, which were in favor of the navigated group. When the cutoff value used for the alignment in the coronal and sagittal plane was 2 degrees or 3 degrees, imageless navigation significantly reduced the outlier rate of the femoral and tibial components compared with the conventional group. Notably, computed tomography scans demonstrated no statistically significant differences between the two groups regarding the outliers in the rotational alignment of the femoral and tibial components; however, there was strong statistical heterogeneity. Conclusions. Our results indicated that imageless computer-assisted navigation systems improve lower limb axis and component orientation in the coronal and sagittal planes, but not the rotational alignment in TKA. Further multiple-center clinical trials with long-term follow-up are needed to determine differences in the clinical and functional outcomes of knee arthroplasties performed using computer-assisted techniques. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:590 / 600
页数:11
相关论文
共 50 条
  • [1] Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
    Leelasestaporn, C.
    Thuwapitchayanant, M.
    Sirithanapipat, P.
    Sa-ngasoongsong, P.
    Ruengsilsuwit, P.
    [J]. MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (01) : 79 - 84
  • [2] Development of an imageless navigation system for total knee arthroplasty
    Su Yingying
    Wang Chengtao
    Qi Yuanshuai
    Yan Shiju
    Gu Lixu
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6060 - 6063
  • [3] Rotational alignment of the tibial component in total knee arthroplasty
    Bindelglass, DF
    [J]. ORTHOPEDICS, 2001, 24 (11) : 1049 - 1052
  • [4] Rotational alignment of the femoral component in total knee arthroplasty
    Castelli, Claudio Carlo
    Falvo, Daniele Antonio
    Iapicca, Mario Luigi
    Gotti, Valerio
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [5] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [6] Navigation improves accuracy of rotational alignment in total knee arthroplasty
    Stöckl, B
    Nogler, M
    Rosiek, R
    Fischer, M
    Krismer, M
    Kessler, O
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 180 - 186
  • [7] The Role of Imageless Computer-Assisted Navigation During Total Knee Arthroplasty on Femoral Component Sagittal Alignment and Outcomes
    Nagarkatti, Ahana
    Strecker, Sara
    Nagarkatti, Durgesh
    Witmer, Dan
    [J]. ARTHROPLASTY TODAY, 2024, 28
  • [8] Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
    Keizo Wada
    Hiroshi Mikami
    Daisuke Hamada
    Hiroshi Yonezu
    Koichi Oba
    Koichi Sairyo
    [J]. Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 271 - 276
  • [9] The effect of computerized navigation on component alignment in total knee arthroplasty
    Machado Soares, Luiz Fernando
    Nunes, Tarcizo Afonso
    Percope De Andrade, Marco Antonio
    Neyret, Philippe
    Badet, Roger
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2013, 47 (01) : 8 - 13
  • [10] Measurement of rotational and coronal alignment in total knee arthroplasty using a navigation system is reproducible
    Wada, Keizo
    Mikami, Hiroshi
    Hamada, Daisuke
    Yonezu, Hiroshi
    Oba, Koichi
    Sairyo, Koichi
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (02) : 271 - 276