Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates of intraocular pressure

被引:45
|
作者
Hamilton, Kirsten Elizabeth [1 ]
Pye, David Cecil [1 ]
Aggarwala, Shivani [1 ]
Evian, Sindy [1 ]
Khosla, Joti [1 ]
Perera, Rachithri [1 ]
机构
[1] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
diurnal variation; intraocular pressure; corneal thickness; tonometry;
D O I
10.1097/IJG.0b013e31802b350f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine whether there is a temporal relationship between the diurnal variation of central corneal thickness (CCT) and intraocular pressure (10P) by Goldmann applanation tonometry in young normal human participants in vivo. Methods: Twenty-five eyes of 25 young healthy normal participants were examined in a prospective observational cross-sectional study. IOP, CCT and corneal curvature were measured using standard clinical techniques over a 24-hour period, and the temporal interrelationships between these parameters were examined. Results: The overnight change in IOP measured by Goldmann tonometry was 3.1 +/- 2.4 mm Hg (P < 0.001), CCT was 20.1 +/- 10.9 im (P = 0.016), with no statistical change in central corneal curvature (0.05 mm, P = 0.477, paired t test with Bonferroni correction). Both IOP and CCT were highest on awakening at 7:00 then dropped rapidly to baseline levels by 9:00 (linear mixed models), and these two parameters were highly correlated (r = 0.978, P < 0.001). After 9:00, there was no correlation between these parameters (r = -0.453, P = 0.260). Conclusions: The results of this study have highlighted a potential link between the diurnal variation of CCT and the accuracy of Goldmann tonometry estimates of IOP during the first 2 hours after awakening. Clinicians should be wary of using Goldmann tonometry to estimate IOP until the overnight increase in CCT has resolved.
引用
收藏
页码:29 / 35
页数:7
相关论文
共 50 条
  • [41] Dynamic contour tonometry and Goldmann applanation tonometry: correlation with intracameral assessment of intraocular pressure
    Riva, Ivano
    Quaranta, Luciano
    Russo, Andrea
    Katsanos, Andreas
    Rulli, Eliana
    Floriani, Irene
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (01) : 55 - 62
  • [42] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    J Y F Ku
    H V Danesh-Meyer
    J P Craig
    G D Gamble
    C N J McGhee
    [J]. Eye, 2006, 20 : 191 - 198
  • [43] Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometry
    Ku, JYF
    Danesh-Meyer, HV
    Craig, JP
    Gamble, GD
    McGhee, CNJ
    [J]. EYE, 2006, 20 (02) : 191 - 198
  • [44] Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
    Saleh, Tarek A.
    Adams, Morag
    McDermott, Bill
    Claridge, Kate G.
    Ewings, Paul
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 516 - 520
  • [45] The Influence of Central Corneal Thickness and Corneal Curvature Radius on The Intraocular Pressure as Measured By Different Tonometers: Noncontact and Goldmann Applanation Tonometers
    Harada, Yukinori
    Hirose, Naofumi
    Kubota, Toshiaki
    Tawara, Akihiko
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (08) : 619 - 625
  • [46] Effects of Central Corneal Stromal Thickness and Epithelial Thickness on Intraocular Pressure Using Goldmann Applanation and Non-Contact Tonometers
    Lee, Marvin
    Ahn, Jaehong
    [J]. PLOS ONE, 2016, 11 (03):
  • [47] Influence of central corneal thickness on applanation tonometry readings
    Jakubaszko, J
    Marek, J
    [J]. SOE 2003: XIV CONGRESS OF THE EUROPEAN SOCIETY OF OPHTHALMOLOGY, 2003, : 181 - 186
  • [48] Central corneal thickness and intraocular pressure relationship in eyes with and without previous LASIK: Comparison of Goldmann applanation tonometer with pneumatonometer
    Baypaktar, S
    Bayraktar, Z
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (01) : 81 - 88
  • [49] Comparison of Intraocular Pressure Measurements Between Goldmann Applanation Tonometry and Reichert 7 Noncontact Tonometry
    Gungor, Sirel G.
    Akman, Ahmet
    Yazici, Ayse C.
    [J]. JOURNAL OF GLAUCOMA, 2015, 24 (06) : 438 - 441
  • [50] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924