Trends in utilization and spending on remote monitoring of pacemakers and implantable cardioverter-defibrillators among Medicare beneficiaries

被引:12
|
作者
Holtzman, Jessica N. [1 ,2 ]
Wadhera, Rishi K. [1 ,2 ]
Choi, Eunhee [1 ,2 ]
Zhao, Tianyi [1 ,2 ]
Secemsky, Eric A. [1 ,2 ]
Fraiche, Ariane M. [1 ,2 ]
Shen, Changyu [1 ,2 ]
Kramer, Daniel B. [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Richard A & Susan F Smith Ctr Outcomes Res Cardio, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
关键词
Health care costs; Health services utilization; Implantable cardioverter-defibrillator; Pacemaker; Remote monitoring; FOLLOW-UP; ELECTRONIC DEVICES; ATRIAL-FIBRILLATION; INTERROGATION;
D O I
10.1016/j.hrthm.2020.05.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND National trends and costs associated with remote and in-office interrogations of pacemakers and implantable cardioverter-defibrillators (ICDs) have not been previously described. OBJECTIVE The purpose of this study was to evaluate utilization and Medicare spending for remote monitoring and in-office interrogations for pacemakers and ICDs. METHODS We performed a retrospective cohort study of claims and spending for remote and in-office interrogations of pacemakers and ICDs for Medicare fee-for-service beneficiaries from 2012 to 2015. Aggregate and per-beneficiary claims and spending were calculated for each device type. RESULTS Among all patients, 41.9% were female and the mean age was 78.3 years. From 2012 to 2015, remote monitoring utilization increased sharply. Aggregate professional remote monitoring claims for pacemakers increased by 61.3% and for ICDs by 5.6%, with an increase in technical claims (combined for pacemakers and ICDs) of 32. 8%. Spending on all remote and in-office interrogations for these devices totaled $160 million per year, with remote costs increasing nearly 25% from $45.4 million in 2012 to $56.7 million in 2015. At the beneficiary level, remote interrogations increased for pacemakers from 0.6 to 0.9 per year, and for ICDs from 1.3 to 1.4 per year, whereas in-office interrogations decreased from 2.8 to 2.7 per year and from 3.0 to 2.9 per year, respectively. Beneficiary-level analysis revealed increased expenditures on remote interrogation offset by decreases in in-office expenditures, with total annual spending decreasing by $2 and $5 per beneficiary, respectively. CONCLUSION Remote monitoring utilization increased substantially from 2012 to 2015, whereas annual costs per beneficiary decreased.
引用
收藏
页码:1917 / 1921
页数:5
相关论文
共 50 条
  • [21] Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
    Burri, Haran
    Senouf, David
    [J]. EUROPACE, 2009, 11 (06): : 701 - 709
  • [22] Remote monitoring of pacemakers and implantable cardioverter-defibrillators, safety aspects and study in cardiac implant patients on EMF exposure
    Plawiak-Mowna, Anna
    Krawczyk, Andrzej
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (12B): : 137 - 140
  • [23] Magnetic Resonance Imaging in Patients With Implantable Cardioverter-Defibrillators and Pacemakers
    Roguin, Ariel
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (06) : 556 - 557
  • [24] Why Are Implantable Cardioverter-Defibrillators and Pacemakers Being Revised Today?
    Hanzlik, J. A.
    Patel, J. D.
    Kurtz, S. M.
    Horn, Q. C.
    Shkolnikov, Y. P.
    Ochoa, J. A.
    Pavri, B. B.
    Greenspon, A. J.
    [J]. MEDICAL DEVICE MATERIALS VI, 2013, : 57 - 62
  • [25] MASK MAGNETS MAY INTERACT WITH PACEMAKERS AND IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    Ruoff, Chad
    Tashman, Yasemin
    Miller, Bernie
    Houser, Ryan
    Cheema, Kamal
    Haley, Caitlin
    Petersen, Ann
    Lizak, Matthew
    Goswami, Umesh
    Lizak, Trevor
    Krahn, Lois
    Srivathsan, Komandoor
    [J]. SLEEP, 2022, 45 : A342 - A343
  • [26] Recommendations for the use of electrocautery in patients with pacemakers and implantable cardioverter-defibrillators
    Nowak, B.
    Israel, C. W.
    Willems, S.
    Baensch, D.
    Butter, C.
    Doll, N.
    Eckardt, L.
    Geller, J. C.
    Klingenheben, T.
    Lewalter, T.
    Schumacher, B.
    Wolpert, C.
    [J]. KARDIOLOGE, 2010, 4 (05): : 383 - 388
  • [27] CLINICAL INTERACTIONS BETWEEN PACEMAKERS AND AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS
    CALKINS, H
    BRINKER, J
    VELTRI, EP
    GUARNIERI, T
    LEVINE, JH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) : 666 - 673
  • [28] Safety of Electromagnetic Articulography in Patients With Pacemakers and Implantable Cardioverter-Defibrillators
    Joglar, Jose A.
    Nguyen, Carol
    Garst, Diane M.
    Katz, William F.
    [J]. JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2009, 52 (04): : 1082 - 1087
  • [30] Radiotherapy in Patients with Pacemakers or implantable Cardioverter-Defibrillators - What to Note?
    Hueltenschmidt, B.
    Hetzel, M.
    Sautter-Bihl, M-L
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 114 - 114