Enantioselective analysis of ibuprofen in human plasma by anionic cyclodextrin-modified electrokinetic chromatography

被引:0
|
作者
Jabor, VAP
Lanchote, VL
Bonato, PS
机构
[1] USP, Fac Ciencias Farmaceut, Dept Fis & Quim, BR-14040903 Ribeirao Preto, SP, Brazil
[2] USP, Fac Filosofia Ciencias & Letras Ribeirao Pret, Dept Quim, BR-14040903 Ribeirao Preto, SP, Brazil
[3] USP, Fac Ciencias Farmaceut, Dept Analises Clin, BR-14040903 Ribeirao Preto, SP, Brazil
关键词
capillary electrophoresis; enantiomeric separation; ibuprofen; plasma samples; validation;
D O I
10.1002/1522-2683(200209)23:17<3041::AID-ELPS3041>3.0.CO;2-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of a rapid method for the enantioselective analysis of the nonsteroidal anti-inflammatory drug ibuprofen in human plasma by capillary electrophoresis employing the anionic cyclodextrin-modified electrokinetic chromatography mode. Sample cleanup was carried out by acidification with HCI followed by liquid-liquid extraction with hexane:isopropanol (99:1 v/v). The complete enantioselective analysis was performed within 10 min, using 100 mmol L-1 phosphoric acid/ triethanolamine buffer, pH 2.6, containing 2.0% w/v sulfated beta-cyclodextrin as chiral selector; fenoprofen, another nonsteroidal anti-inflammatory drug, was used as internal standard. The calibration curves were linear over the concentration range of 0.25-125.0 mug mL(-1) for each enantiomer of ibuprofen. The mean recoveries for ibuprofen enantiomers were up to 85%. The enantiomers studied could be quantified at three different concentrations (0.5, 5.0 and 50.0 mug mL-1) with a coefficient of variation and relative error not higher than 15%. The quantitation limit was 0.2 mug mL(-1) for (+)-(S)and (-)-(R)-ibuprofen using 1 mL of human plasma. The plasma endogenous compounds and other drugs did not interfere with the present assay. The analysis of real plasma samples obtained from a healthy volunteer after administration of 600 mg of racemic ibuprofen showed a maximum plasma level of 29.6 and 39.9 mug mL(-1) of (-)-(R)- and (+)-(S)- ibuprofen, respectively, and the area under plasma concentration-time curve AUC(0-chi) (+)-(S)/AUC(0-chi) (-)-(R) ratio was 1.87.
引用
收藏
页码:3041 / 3047
页数:7
相关论文
共 50 条
  • [31] DETERMINATION OF THE ENANTIOMER OF A CHOLESTEROL-LOWERING DRUG BY CYCLODEXTRIN-MODIFIED MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    NOROSKI, JE
    MAYO, DJ
    MORAN, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (01) : 45 - 52
  • [32] Separation of monomethyl-benz[a]anthracene isomers using cyclodextrin-modified electrokinetic chromatography
    Akbay, C
    Shamsi, SA
    Warner, IM
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) : 147 - 155
  • [33] Determination of oleanolic acid and ursolic acid in cornel by cyclodextrin-modified micellar electrokinetic chromatography
    Zhang, GQ
    Qi, YP
    Lou, ZY
    Liu, CH
    Wu, XF
    Chai, YF
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (07) : 529 - 532
  • [34] Determination of the chiral and achiral related substances of methotrexate by cyclodextrin-modified micellar electrokinetic chromatography
    Gotti, R
    El-Hady, DA
    Andrisano, V
    Bertucci, C
    El-Maali, NA
    Cavrini, V
    ELECTROPHORESIS, 2004, 25 (16) : 2830 - 2837
  • [35] Determination of active constituents in rhubarb by cyclodextrin-modified micellar electrokinetic chromatography with bile salt
    Shang, XY
    Yuan, ZB
    ANALYTICAL LETTERS, 2002, 35 (06) : 985 - 993
  • [36] Application of cyclodextrin-modified micellar electrokinetic chromatography to the separations of selected neutral pesticides and their enantiomers
    Schmitt, P
    Garrison, AW
    Freitag, D
    Kettrup, A
    JOURNAL OF CHROMATOGRAPHY A, 1997, 792 (1-2) : 419 - 429
  • [37] Simultaneous separation and determination of hirsutine and hirsuteine by cyclodextrin-modified micellar electrokinetic capillary chromatography
    Wang, Mengli
    Guo, Jing
    Wang, Zhiying
    Zhang, Guangbin
    Yu, Haixia
    Chang, Ruimiao
    Chen, Anjia
    PHYTOCHEMICAL ANALYSIS, 2020, 31 (01) : 112 - 118
  • [39] Capillary electrophoresis of tetrahydroberberine alkaloids: Chiral separation by cyclodextrin-modified micellar electrokinetic chromatography
    Koyama, Junko
    Toyokuni, Izumi
    Kino, Akari
    Tagahara, Kiyoshi
    Phytochemical Analysis, 10 (04): : 175 - 180
  • [40] On-line preconcentration and chiral separation of propiconazole by cyclodextrin-modified micellar electrokinetic chromatography
    Ibrahim, Wan Aini Wan
    Hermawan, Dadan
    Sanagi, Mom Marsin
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1170 (1-2) : 107 - 113