共 50 条
EFFECT OF HEATING TEMPERATURE ON DEUTERIUM RETENTION BEHAVIOR FOR HELIUM/CARBON IMPLANTED TUNGSTEN
被引:8
|作者:
Sato, Misaki
[1
]
Yuyama, Kenta
[1
]
Li, Xiao-Chun
[1
]
Ashikawa, Naoko
[2
]
Sagara, Akio
[2
]
Yoshida, Naoaki
[3
]
Chikada, Takumi
[1
]
Oya, Yasuhisa
[1
]
机构:
[1] Shizuoka Univ, Grad Sch Sci, Suruga Ku, Shizuoka 4228529, Japan
[2] Natl Inst Nat Sci, Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
[3] Kyushu Univ, Appl Mech Res Inst, Kasuga, Fukuoka 8168580, Japan
关键词:
IRRADIATION;
D O I:
10.13182/FST14-971
中图分类号:
TL [原子能技术];
O571 [原子核物理学];
学科分类号:
0827 ;
082701 ;
摘要:
The effect of heating temperature on deuterium (D) retention behavior for helium (He+) / carbon (C+) implanted tungsten (W) was studied. It was found that D retention behavior for He+ implanted W was not limited by the size of the He bubbles. The microstructure observation showed that the large helium bubbles were formed near the surface for He+ implanted W at 1173 K, suggesting that the D retention was reduced by the growth of the helium bubbles. In addition, to evaluate the effect of implantation ion species at high temperature, D retention behavior for He+ implanted W at 1173 K was compared with that for C+ implanted W at 673 K It is concluded that the D retention depends on ion species, which makes different kinds of damages like He bubbles for He+ implantation and vacancy-ion complex (voids) for C+ implantation.
引用
收藏
页码:531 / 534
页数:4
相关论文