Application of a metal free high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) for the determination of chromium species in drinking and tap water

被引:33
|
作者
Catalani, Simona [1 ]
Fostinelli, Jacopo [1 ]
Gilberti, Maria Enrica [1 ]
Apostoli, Pietro [1 ]
机构
[1] Univ Brescia, Unit Occupat Hlth & Ind Hyg, Dept Med & Surg Specialties, Radiol Sci & Publ Hlth, I-25121 Brescia, Italy
关键词
HPLC-ICP-MS; DRC; Trivalent chromium; Hexavalent chromium; Drinking waters; Tap waters; ION CHROMATOGRAPHY; SPECIATION; SELENIUM; CR(III); CR(VI);
D O I
10.1016/j.ijms.2015.06.015
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
In some environmental and occupational setting, determination of total chromium is inadequate for a complete toxicological evaluation and risk assessment because the toxicity and bioavailability of chromium depend upon the form or species. In this study, trivalent and hexavalent chromium compounds were determined by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) equipped with dynamic reaction cells (DRCs) and a reversed-phase C8 column. All the instruments and devices were metal free, thus avoiding any interference caused by leaching from metallic components. The mobile phase (EDTA(2)(Na) 5 mM pH 7, 40 degrees C) directly forms a complex with the Cr(III) in the preheated, allowing a single chromatographic method to be used to separate the Cr(III) EDTA complex and the Cr(VI). This analytical method was applied in several samples of mineral and tap water with the aim to determine a different ratio of Cr(III) and Cr(VI). In tap waters Cr(VI), ranged from 10.88 to 0.1 mu g/L while Cr(III) ranged from.0.33 to 0.1 mu g/L. The highest levels of Cr(VI) were measured in Brescia, a highly industrialized province in northern Italy in which high levels of Cr(VI) have been a public health concern. In commercial mineral waters, the range of Cr(III) and Cr(VI) were 0.11-0.80 mu g/L and 0.25-3.4 mu g/L, respectively. The method applied in this study is a rapid, sensitive (LOD 0.1 mu g/L) and specific technique for determination of chromium species in water. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 50 条
  • [31] Determination of Bromine and Iodine Speciation in Drinking Water Using High Performance Liquid Chromatography-Inductively Coupled Plasma-Mass Spectrometry
    Liu, Wei
    Yang, Hongxia
    Li, Bing
    Xu, Siqi
    Geostandards and Geoanalytical Research, 2011, 35 (01): : 69 - 74
  • [32] DETERMINATION OF ARSENIC SPECIES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    BEAUCHEMIN, D
    SIU, KWM
    MCLAREN, JW
    BERMAN, SS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) : 285 - 289
  • [33] Determination of Trace Migratory Chromium(VI) in Toys by High Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry
    Wang Xin
    Xing Yuan-Na
    Chen Ze-Yong
    Huo Ju-Yuan
    Chen Li-Qiong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (01) : 123 - 127
  • [34] Determination of hexavalent chromium in traditional Chinese medicines by high-performance liquid chromatography with inductively coupled plasma mass spectrometry
    Li, Peng
    Li, Li-min
    Xia, Jing
    Cao, Shuai
    Hu, Xin
    Lian, Hong-Zhen
    Ji, Shen
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (23) : 4043 - 4047
  • [35] Simultaneous Separation of Sb(III) and Sb(V) by High Performance Liquid Chromatography (HPLC) - Inductively Coupled Plasma - Mass Spectrometry (ICP-MS) with Application to Plants, Soils, and Sediments
    Zhang, Zhaoxue
    Lu, Yi
    Li, Haipu
    Zhang, Nan
    Cao, Junfei
    Qiu, Bo
    Yang, Zhaoguang
    ANALYTICAL LETTERS, 2021, 54 (06) : 919 - 934
  • [36] Rapid determination of iodine content in drinking water by isopropyl sensitization and inductively coupled plasma mass spectrometry (ICP-MS)
    Zeng, Yanxia
    Zhu, Xiashi
    2021 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY, ENVIRONMENT AND CHEMICAL SCIENCE (AEECS 2021), 2021, 245
  • [37] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [38] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [39] APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) FOR TRACE-METAL DETERMINATION IN FOODS
    MUNRO, S
    EBDON, L
    MCWEENY, DJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (03) : 211 - 219
  • [40] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371