Using videotaped specimens to test quality control in a computer-assisted semen analysis system

被引:6
|
作者
Boone, WR [1 ]
Jones, JM [1 ]
Shapiro, SS [1 ]
机构
[1] Univ Wisconsin, Dept Obstet & Gynecol, Madison, WI 53706 USA
关键词
computer-assisted semen analysis; CASA; quality control; semen analysis; videotapes;
D O I
10.1016/S0015-0282(99)00575-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine the feasibility of using semen samples previously recorded on videotape for intralaboratory and interlaboratory quality control of computer-assisted semen analysis (CASA) systems. Design: Blinded, controlled study. Setting: Pooled semen specimens from two normal human volunteers in an academic research environment. Patient(s): None. Intervention(s): None. Main Outcome Measure(s): Semen parameters from a videotape analyzed internally and by four external laboratories. Result(s): Preliminary experiments designed to examine intralaboratory variation by repeated analysis of semen samples recorded on videotape revealed some significant differences for every variable examined. When these data were analyzed by using the larger biologic error caused by subsampling, no significant differences were found for any of the variables examined. When either a standard set or the specific laboratories' sets of parameters were used to analyze the same videotaped semen specimen, no statistically significant differences were detected for sperm concentration for motility among the five laboratories after the biological error caused by subsampling was applied to results. Conclusion(s): These data strongly suggest that videotaped semen specimens can serve as quality control for intralaboratory and interlaboratory testing of CASA equipment as long as the biologic error caused by subsampling is used to compare results. (C) 2000 by American Society for Reproductive Medicine.
引用
收藏
页码:636 / 640
页数:5
相关论文
共 50 条
  • [31] COMPUTER-ASSISTED HUMAN-SEMEN ANALYSIS SAMPLING ERRORS AND REPRODUCIBILITY
    GINSBURG, KA
    MOGHISSI, KS
    ABEL, EL
    JOURNAL OF ANDROLOGY, 1988, 9 (02): : 82 - 90
  • [32] Application of computer-assisted semen analysis to explain variations in pig fertility
    Broekhuijse, M. L. W. J.
    Sostaric, E.
    Feitsma, H.
    Gadella, B. M.
    JOURNAL OF ANIMAL SCIENCE, 2012, 90 (03) : 779 - 789
  • [33] Computer-assisted semen analysis parameters in men with varicocele: Is surgery helpful?
    Parikh, FR
    Kamat, SA
    Kodwaney, GG
    Balaiah, D
    FERTILITY AND STERILITY, 1996, 66 (03) : 440 - 445
  • [34] Accuracy of computer-assisted semen analysis in prefreeze and post-thaw specimens with high and low sperm counts and motility
    Sidhu, RS
    Sharma, RK
    Lee, JC
    Agarwal, A
    UROLOGY, 1998, 51 (02) : 306 - 312
  • [35] COMPUTER-ASSISTED RECORDING OF LIVE AND VIDEOTAPED HORSE BEHAVIOR - RELIABILITY STUDIES
    MCDONNELL, SM
    DIEHL, NK
    APPLIED ANIMAL BEHAVIOUR SCIENCE, 1990, 27 (1-2) : 1 - 7
  • [36] A comparison of bovine seminal quality assessments using different viewing chambers with a computer-assisted semen analyzer
    Lenz, R. W.
    Kjelland, M. E.
    VonderHaar, K.
    Swannack, T. M.
    Moreno, J. F.
    JOURNAL OF ANIMAL SCIENCE, 2011, 89 (02) : 383 - 388
  • [37] Use of computer-assisted sperm analysis and flow cytometry to detect seasonal variations of bovine semen quality
    Malama, E.
    Zeronb, Y.
    Janett, F.
    Siuda, M.
    Roth, Z.
    Bollwein, H.
    THERIOGENOLOGY, 2017, 87 : 79 - 90
  • [39] Assessment of motion and kinematic characteristics of frozen-thawed Sirohi goat semen using computer-assisted semen analysis
    Anand, Mukul
    Yadav, Sarvajeet
    VETERINARY WORLD, 2016, 9 (02) : 203 - 206
  • [40] Computer-assisted test assembly using optimization heuristics
    Luecht, RM
    APPLIED PSYCHOLOGICAL MEASUREMENT, 1998, 22 (03) : 224 - 236