Efficient Interface for Online Coupling of Capillary Electrophoresis with Inductively Coupled Plasma-Mass Spectrometry and Its Application in Simultaneous Speciation Analysis of Arsenic and Selenium

被引:46
|
作者
Liu, Lihong [1 ]
Yun, Zhaojun [1 ]
He, Bin [1 ]
Jiang, Guibin [1 ]
机构
[1] Chinese Acad Sci, State Key Lab Environm Chem & Ecotoxicol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
关键词
ATOMIC FLUORESCENCE SPECTROMETRY; HYDRIDE GENERATION; ICP-MS; CHROMATOGRAPHY; ION; ABSORPTION; EXTRACTION; SEPARATION; MERCURY; SAMPLES;
D O I
10.1021/ac501347d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly efficient online system coupling of capillary electrophoresis to inductively coupled plasma-mass spectrometry (CE-ICP-MS) for simultaneous separation and determination of arsenic and selenium compounds was developed. CE was coupled to an ICP-MS system by a sprayer with a novel direct-injection high-efficiency nebulizer (DIHEN) chamber as the interface. By using this interface, six arsenic species, including arsenite (As(III), arsenate (As(V)), monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), and arsenocholine (AsC) and five selenium species (such as sodium selenite (Se(IV)), sodium selenate (Se(VI)), selenocysteine (SeCys), selenomethionine (SeMet), and Se-methylselenocysteine (MeSeCys)) were baseline-separated and determined in a single run within 9 min under the optimized conditions. Minimum dead volume, low and steady sheath flow liquid, high nebulization efficiency, and high sample transport efficiency were obtained by using this interface. Detection limits were in the range of 0.11-0.37 mu g L-1 for the six arsenic compounds (determined as As-75 at m/z 75) and 1.33-2.31 mu g L-1 for the five selenium species (determined as Se-82 at m/z 82). Repeatability expressed as the relative standard deviations (RSD, n = 6) of both migration time and peak area were better than 2.68% for arsenic compounds and 3.28% for selenium compounds, respectively. The proposed method had been successfully applied for the determination of arsenic and selenium species in the certified reference materials DORM-3, water, urine, and fish samples.
引用
收藏
页码:8167 / 8175
页数:9
相关论文
共 50 条
  • [41] INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - APPLICATION TO THE DETERMINATION OF ARSENIC SPECIES
    THOMAS, P
    SNIATECKI, K
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5): : 410 - 414
  • [42] Iodine speciation in biological samples by capillary electrophoresis - inductively coupled plasma mass spectrometry
    Michalke, B
    Schramel, P
    ELECTROPHORESIS, 1999, 20 (12) : 2547 - 2553
  • [43] Interfacing microchip capillary electrophoresis with inductively coupled plasma mass spectrometry for chromium speciation
    Greenway, G.M. (G.M.Greenway@hull.ac.uk), 1600, Royal Society of Chemistry (18):
  • [44] Capillary electrophoresis inductively coupled plasma mass spectrometry
    Majidi, V
    MICROCHEMICAL JOURNAL, 2000, 66 (1-3) : 3 - 16
  • [45] Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry for redox speciation of plutonium
    Ambard, C
    Delorme, A
    Baglan, N
    Aupiais, J
    Pointurier, F
    Madic, C
    RADIOCHIMICA ACTA, 2005, 93 (11) : 665 - 673
  • [46] Interfacing microchip capillary electrophoresis with inductively coupled plasma mass spectrometry for chromium speciation
    Song, QJ
    Greenway, GM
    McCreedy, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (01) : 1 - 3
  • [47] Selenium speciation in watermelon by g-C3N4 enrichment combined with capillary electrophoresis-inductively coupled plasma-mass spectrometry
    Feng Jinsu
    Cao Yupin
    Mo Guichun
    Tang Lifu
    Deng Biyang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (10) : 1224 - 1231
  • [48] Arsenic speciation by coupling capillary zone electrophoresis with mass spectrometry
    Debusschere, L
    Demesmay, C
    Rocca, JL
    CHROMATOGRAPHIA, 2000, 51 (5-6) : 262 - 268
  • [49] Arsenic speciation by coupling capillary zone electrophoresis with mass spectrometry
    L. Debusschere
    C. Demesmay
    J. L. Rocca
    Chromatographia, 2000, 51 : 262 - 268
  • [50] ARSENIC SPECIATION BY COUPLING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    DEMESMAY, C
    OLLE, M
    PORTHAULT, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (03): : 205 - 210