Experimental validation of tangential resolution improvement in photoacoustic tomography using modified delay-and-sum reconstruction algorithm

被引:53
|
作者
Kalva, Sandeep Kumar [1 ]
Pramanik, Manojit [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, 62 Nanyang Dr, Singapore 637459, Singapore
关键词
image reconstruction; tangential resolution; photoacoustic tomography; thermoacoustic tomography; THERMOACOUSTIC TOMOGRAPHY; LASER-DIODE; SYSTEM; DESIGN; IMAGES; BRAIN;
D O I
10.1117/1.JBO.21.8.086011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For a circular scanning geometry in photoacoustic tomography, the axial/radial resolution is spatially invariant and is not affected by the ultrasound transducer (UST, detector) aperture. However, the tangential resolution is dependent on the detector aperture size and it varies spatially. Many techniques were proposed to improve the tangential resolution, such as attaching a concave lens in front of the nonfocused transducer or using a virtual point detector. Both of these methods have difficulties. Therefore, a modified delay-and-sum reconstruction algorithm has been proposed which can be used together with a standard ultrasound detector (nonfocused) to improve the tangential resolution. In this work, we validate the modified delay-and-sum algorithm experimentally for both flat and cylindrically focused USTs. More than threefold improvement in tangential resolution is observed. It is also shown that the object shape is recovered with this modified algorithm, which is very helpful for diagnosis and treatment purposes. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:8
相关论文
共 43 条
  • [41] High-Temporal Resolution Dual-Energy Computed Tomography of the Heart Using a Novel Hybrid Image Reconstruction Algorithm: Initial Experience
    Nance, John William, Jr.
    Bastarrika, Gorka
    Kang, Doo Kyoung
    Ruzsics, Balazs
    Vogt, Sebastian
    Schmidt, Bernhard
    Raupach, Rainer
    Flohr, Thomas G.
    Schoepf, U. Joseph
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (01) : 119 - 125
  • [42] Low power 2D finite impulse response filter design using modified artificial bee colony algorithm with experimental validation using field-programmable gate array
    Dwivedi, Atul Kumar
    Ghosh, Subhojit
    Londhe, Narendra D.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2016, 10 (06) : 671 - 678
  • [43] Quantification of Cisplatin Using a Modified 3-Material Decomposition Algorithm at Third-Generation Dual-Source Dual-Energy Computed Tomography An Experimental Study
    Sofue, Keitaro
    Itoh, Toshihide
    Takahashi, Satoru
    Schmidt, Bernhard
    Shimada, Ryuji
    Negi, Noriyuki
    Sugimura, Kazuro
    Murakami, Takamichi
    INVESTIGATIVE RADIOLOGY, 2018, 53 (11) : 673 - 680