Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry

被引:137
|
作者
Huang, Jinhai [1 ,2 ]
McAlinden, Colm [1 ,3 ,4 ]
Huang, Yingying [1 ]
Wen, Daizong [5 ]
Savini, Giacomo [6 ]
Tu, Ruixue [1 ]
Wang, Qinmei [1 ,2 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[2] Minist Hlth PR China, Key Lab Vis Sci, Wenzhou, Zhejiang, Peoples R China
[3] ABM Univ Hlth Board, Morriston Hosp, Swansea, W Glam, Wales
[4] Flinders Univ S Australia, Adelaide, SA, Australia
[5] 180 Hosp Chinese PLA, Dept Ophthalmol, Quanzhou, Fujian, Peoples R China
[6] GB Bietti Fdn IRCCS, Rome, Italy
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
基金
中国国家自然科学基金;
关键词
INTRAOCULAR-LENS POWER; ACCURACY; DEVICE; QUALITY; ERROR;
D O I
10.1038/srep43414
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A meta-analysis to compare ocular biometry measured by optical low-coherence reflectometry (Lenstar LS900; Haag Streit) and partial coherence interferometry (the IOLMaster optical biometer; Carl Zeiss Meditec). A systematic literature search was conducted for articles published up to August 6th 2015 in the Cochrane Library, PubMed, Medline, Embase, China Knowledge Resource Integrated Database and Wanfang Data. A total of 18 studies involving 1921 eyes were included. There were no statistically significant differences in axial length (mean difference [MD] 0 mm; 95% confidence interval (CI) -0.08 to 0.08 mm; p = 0.92), anterior chamber depth (MD 0.02 mm; 95% CI -0.07 to 0.10 mm; p = 0.67), flat keratometry (MD -0.05 D; 95% CI -0.16 to 0.06 D; p = 0.39), steep keratometry (MD -0.09 D; 95% CI -0.20 to 0.03 D; p = 0.13), and mean keratometry (MD -0.15 D; 95% CI -0.30 to 0.00 D; p = 0.05). The white to white distance showed a statistically significant difference (MD -0.14 mm; 95% CI -0.25 to -0.02 mm; p = 0.02). In conclusion, there was no difference in the comparison of AL, ACD and keratometry readings between the Lenstar and IOLMaster. However the WTW distance indicated a statistically significant difference between the two devices. Apart from the WTW distance, measurements for AL, ACD and keratometry readings may be used interchangeability with both devices.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Comparison of anterior ocular biometry between optical low-coherence reflectometry and anterior segment optical coherence tomography in an adult Chinese population
    Shen, Peiyang
    Ding, Xiaohu
    Congdon, Nathan G.
    Zheng, Yingfeng
    He, Mingguang
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 966 - 970
  • [22] BRAGG GRATING CHARACTERIZATION BY OPTICAL LOW-COHERENCE REFLECTOMETRY
    LAMBELET, P
    FONJALLAZ, PY
    LIMBERGER, HG
    SALATHE, RP
    ZIMMER, C
    GILGEN, HH
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 1993, 5 (05) : 565 - 567
  • [23] MULTIPLEXED SENSING USING OPTICAL LOW-COHERENCE REFLECTOMETRY
    SORIN, WV
    BANEY, DM
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 1995, 7 (08) : 917 - 919
  • [24] Analysis of distributed feedback lasers using optical low-coherence reflectometry
    Wiedmann, U
    Gallion, P
    Jaouen, Y
    Chabran, C
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 1998, 16 (05) : 864 - 869
  • [25] The Effect of Cycloplegia on the Biometer for Optical Low-coherence Reflectometry
    Yakar, Konuralp
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2023,
  • [26] Optical low-coherence reflectometry for nondestructive process measurements
    Randall, SL
    Brodsky, AM
    Burgess, LW
    Green, RL
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 22A AND 22B, 2003, 20 : 1713 - 1720
  • [27] Low-coherence interferometry with synthesis of coherence function
    Teramura, Y
    Suzuki, K
    Suzuki, M
    Kannari, F
    [J]. APPLIED OPTICS, 1999, 38 (28) : 5974 - 5980
  • [28] Multicenter study of optical low-coherence interferometry and partial-coherence interferometry optical biometers with patients from the United States and China
    Hoffer, Kenneth J.
    Shammas, H. John
    Savini, Giacomo
    Huang, Jinhai
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 62 - 67
  • [29] Comparison of preoperative and postoperative measurements of optical low-coherence reflectometry biometry and assessment of its refractive predictability
    İrfan Akalın
    Melek Tüfek
    Mustafa Türkyılmaz
    Faruk Öztürk
    [J]. International Ophthalmology, 2019, 39 : 1337 - 1343
  • [30] Validation of Optical Low Coherence Reflectometry Retinal and Choroidal Biometry
    Read, Scott A.
    Collins, Michael J.
    Alonso-Caneiro, David
    [J]. OPTOMETRY AND VISION SCIENCE, 2011, 88 (07) : 855 - 863