Three-dimensional mechanical evaluation of joint contact pressure in 12 periacetabular osteotomy patients with 10-year follow-up

被引:65
|
作者
Armiger, Robert S. [1 ]
Armand, Mehran [1 ,3 ]
Tallroth, Kaj [2 ]
Lepisto, Jyri [2 ]
Mears, Simon C. [3 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD USA
[2] ORTON Orthopaed Hosp, Invalid Fdn, Helsinki, Finland
[3] Johns Hopkins Bayview Med Ctr, Dept Orthopaed Surg, Baltimore, MD USA
关键词
HIP-JOINT; COMPUTER-SIMULATION; DYSPLASTIC HIPS; PREDICT; MODEL;
D O I
10.3109/17453670902947390
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Because of the varying structure of dysplastic hips, the optimal realignment of the joint during periacetabular osteotomy (PAO) may differ between patients. Three-dimensional (3D) mechanical and radiological analysis possibly accounts better for patient-specific morphology, and may improve and automate optimal joint realignment. Patients and methods We evaluated the 10-year outcomes of 12 patients following PAO. We compared 3D mechanical analysis results to both radiological and clinical measurements. A 3D discrete-element analysis algorithm was used to calculate the pre- and postoperative contact pressure profile within the hip. Radiological angles describing the coverage of the joint were measured using a computerized approach at actual and theoretical orientations of the acetabular cup. Quantitative results were compared using postoperative clinical evaluation scores (Harris score), and patient-completed outcome surveys (q-score) done at 2 and 10 years. Results The 3D mechanical analysis indicated that peak joint contact pressure was reduced by an average factor of 1.7 subsequent to PAO. Lateral coverage of the femoral head increased in all patients; however, it did not proportionally reduce the maximum contact pressure and, in 1 case, the pressure increased. This patient had the lowest 10-year q-score (70 out of 100) of the cohort. Another hip was converted to hip arthroplasty after 3 years because of increasing osteoarthritis. Interpretation The 3D analysis showed that a reduction in contact pressure was theoretically possible for all patients in this cohort, but this could not be achieved in every case during surgery. While intraoperative factors may affect the actual surgical outcome, the results show that 3D contact pressure analysis is consistent with traditional PAO planning techniques (more so than 2D analysis) and may be a valuable addition to preoperative planning and intraoperative assessment of joint realignment.
引用
收藏
页码:155 / 161
页数:7
相关论文
共 50 条
  • [31] 10-YEAR FOLLOW-UP OF 100 PATIENTS ADMITTED TO A MENTAL HOSPITAL
    CAHN, CH
    CANADIAN PSYCHIATRIC ASSOCIATION JOURNAL, 1972, 17 (06): : 429 - 432
  • [32] A 10-year follow-up of alendronate-treated young patients
    Cimaz, R.
    Bianchi, M. L.
    Biggioggero, M.
    Buoncompagni, A.
    Corona, F.
    Falcini, F.
    Lepore, L.
    Zulian, F.
    Nacci, F.
    Beltramelli, M.
    BONE, 2007, 40 (06) : S26 - S27
  • [33] Rheumatoid Arthritis Patients with Carotid Plaque: 10-Year Follow-up
    Vera-Pineda, Raymundo
    Cardenas-de La Garza, Alberto
    Galarza-Delgado, Dionicio A.
    Ramon Azpiri-Lopez, Jose
    Colunga-Pedraza, Iris J.
    Munoz De Hoyos, Jorge
    Serna-Pena, Griselda
    Tovar-Jasso, Brenda B.
    Alberto Garza-Elizondo, Mario
    Ornelas, Gerardo
    ARTHRITIS & RHEUMATOLOGY, 2015, 67
  • [34] 10-YEAR FOLLOW-UP OF 50 PATIENTS WITH BULIMIA-NERVOSA
    COLLINGS, S
    KING, M
    BRITISH JOURNAL OF PSYCHIATRY, 1994, 164 : 80 - 87
  • [35] Tracing patients with myocardial infarction for a 10-year follow-up study
    Froelicher, ES
    NURSING RESEARCH, 1996, 45 (06) : 341 - 344
  • [36] Cardiac tamponade in medical patients: A 10-year follow-up survey
    Cornily, Jean-Christophe
    Pennec, Pierre-Yves
    Castellant, Philippe
    Bezon, Eric
    Le Gal, Gregoire
    Gilard, Martine
    Jobic, Yannick
    Boschat, Jacques
    Blanc, Jean-Jacques
    CARDIOLOGY, 2008, 111 (03) : 197 - 201
  • [37] ORTHOSTATIC HYPOTENSION IN DIABETIC PATIENTS: 10-YEAR FOLLOW-UP STUDY
    Gaspar, L.
    Kruzliak, P.
    Komornikova, A.
    Celecova, Z.
    Krahulec, B.
    Balaz, D.
    Sabaka, P.
    Caprnda, M.
    Kucera, M.
    Rodrigo, L.
    Soucek, M.
    Uehara, Y.
    Dukat, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A66 - A66
  • [38] 10-YEAR FOLLOW-UP OF PATIENTS UNDERGOING VEIN GRAFT ANGIOPLASTY
    DOUGLAS, JS
    KING, SB
    CIRCULATION, 1994, 90 (04) : 333 - 333
  • [39] 10-YEAR FOLLOW-UP ON THE PERFORMANCE OF A TELEMETRIC INTRACRANIAL-PRESSURE SENSOR
    GUCER, G
    VIERNSTEIN, L
    WANG, A
    SZYMANSKI, R
    NEUROSURGERY, 1988, 22 (05) : 892 - 895
  • [40] A 10-YEAR TO 15-YEAR FOLLOW-UP OBSERVATION OF HIGH TIBIAL OSTEOTOMY IN MEDIAL COMPARTMENT OSTEOARTHROSIS
    YASUDA, K
    MAJIMA, T
    TSUCHIDA, T
    KANEDA, K
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (282) : 186 - 195