Stability of large room airflow structures in a ventilated room

被引:9
|
作者
Kandzia, Claudia [1 ]
Mueller, Dirk [1 ]
机构
[1] Rhein Westfal TH Aachen, EON Energy Res Ctr, Inst Energy Efficient Bldg & Indoor Climate, Aachen, Germany
关键词
Experimental investigation; stable and unstable room airflows; Archimedes number; DISPLACEMENT VENTILATION; SYSTEMS;
D O I
10.1080/14733315.2017.1332730
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a new set of experimental data for different kinds of room airflows in a ventilated room. The data are used to examine Archimedes number effects on the behaviour of large-scale flow structures and their stability versus time. All experiments are performed in a simplified room geometry, representing a small meeting room, a train or an airplane cabin. The supply air is introduced at the ceiling and the exhaust air leaves the room at the bottom zone. The heating power is realised by four controllable heat sources in the lower part of the model room. The experimental investigations apply different supply air set-ups as well as changing supply air velocities and a variation of the heating power. The data of the experiments indicate that the room geometry-based Ar number can be used to distinguish between unstable to stable room airflow structures. Low velocities and high thermal loads cause time depended, unstable room airflows. Neither the forced nor the free convection dominates the flow structure. By increasing the inlet velocity, the airflow structure gets more stable. Large eddies occur between the heat sources and the ceiling of the model room. This experimental investigation showed that it is possible to determine an Ar number for the room geometry under investigation, in the region where a transition takes place from instable to stable airflow. The value of this critical Ar number has been extracted from a qualitative velocity profile analysis.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [21] NUMERICAL AND EXPERIMENTAL STUDY OF 3D TURBULENT AIRFLOW IN A FULL SCALE HEATED VENTILATED ROOM
    Lariani, A.
    Nesreddine, H.
    Galanis, N.
    [J]. ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2009, 3 (01) : 1 - 14
  • [22] Concentration distribution in a mixing ventilated room
    Jensen, RL
    Pedersen, DN
    Nielsen, PV
    Topp, C
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 73 - 80
  • [23] Research of fractal and chaotic characteristics on room airflow and outdoor airflow
    Shu, HW
    Ma, JX
    Zhang, DC
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 317 - 324
  • [24] AIR MIXING IN A MECHANICALLY VENTILATED ROOM
    LEONARD, JJ
    MCQUITTY, JB
    [J]. CANADIAN AGRICULTURAL ENGINEERING, 1988, 30 (01): : 185 - 189
  • [25] LARGE NONLINEARITIES IN ROOM-TEMPERATURE GAAS STRUCTURES
    MILLER, DAB
    CHEMLA, DS
    SMITH, PW
    GOSSARD, AC
    TSANG, WT
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (12) : 1783 - 1783
  • [26] A CFD study for airflow distributions at floor level in a slot-outlet and slot-inlet ventilated room
    Yue, Z
    [J]. ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 614 - 621
  • [27] Dynamic airflow simulation within an isolation room
    Shih, Yang-Cheng
    Chiu, Cheng-Chi
    Wang, Oscar
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3194 - 3209
  • [28] Validation of fast fluid dynamics for room airflow
    Zuo, Wangda
    Chen, Qingyan
    [J]. BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 980 - 983
  • [29] Airflow Path Matters Patient Room HVAC
    Khankari, Kishor
    [J]. ASHRAE JOURNAL, 2016, 58 (06) : 16 - 26
  • [30] Modeling and validation of fire induced airflow in a room
    Wang, J
    Hua, JS
    Kumar, K
    Kumar, S
    [J]. PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL 4, PTS A and B, 2004, 4 : 1164 - 1170