Online measurement of urea concentration in spent dialysate during hemodialysis

被引:4
|
作者
Olesberg, JT [1 ]
Armitage, B [1 ]
Arnold, MA [1 ]
Flanigan, MJ [1 ]
机构
[1] Univ Iowa, Dept Chem & Opt Sci, Iowa City, IA 52242 USA
关键词
urea; hemodialysis; noninvasive; spectroscopy; online monitoring; creatinine;
D O I
10.1117/12.468312
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe on-line optical measurements of urea concentration during the regular hemodialysis treatment of several patients. The spectral measurements were performed in the effluent dialysate stream after the dialysis membrane using an FTIR spectrometer equipped with a flow-through cell. Spectra were recorded across the 5000-4000 cm(-1) (2.0-2.5 mum) wavelength range at 1-minute intervals. Optically determined concentrations matched concentrations obtained from standard chemical assays with a root-mean-square error of 0.29 mM for urea (0.8 mg/dl urea nitrogen), 0.03 MM for creatinine, 0.11 mM for lactate, and 0.22 mM for glucose. The observed concentration ranges were 0-11 mm for urea, 00.35 mM for creatinine, 0-0.75 mM for lactate, and 9-12.5 mM for glucose.
引用
收藏
页码:95 / 105
页数:11
相关论文
共 50 条
  • [21] Quantification of urea extraction during hemodialysis (HD) by urea kinetic modeling and simplified dialysate collection.
    Knoflach, A
    Nadig, C
    Binswanger, U
    [J]. KIDNEY INTERNATIONAL, 1996, 50 (04) : 1427 - 1427
  • [22] ONLINE MONITORING OF UREA IN EFFLUENT LIQUID DURING HEMODIALYSIS
    ORELLANA, A
    MARTINEZFABREGAS, E
    ALEGRET, S
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (10) : 921 - 926
  • [23] Blunted Insulinemia Using High Dialysate Glucose Concentration During Hemodialysis
    Czabak-Garbacz, Roza
    Schneditz, Daniel
    Zierler, Edda
    Eichmann, Eva
    Harter, Gerson
    Hafner-Giessauf, Hildegard
    Obermayer-Pietsch, Barbara
    [J]. ASAIO JOURNAL, 2011, 57 (05) : 444 - 450
  • [24] ON-LINE MONITORING OF URIC ACID CONCENTRATION IN SPENT DIALYSATE DURING HEMODIALYSIS ACCOMPANIED BY GRADUATED PHYSICAL EXERCISES WITH THE BISPECTRAL OPTICAL SENSOR
    Vasilevsky, Aleksandr
    Konoplev, Georgy
    Lopatenko, Oksana
    Komashnya, Artemy
    Visnevsky, Konstantin
    Gerasimchuk, Roman
    Neivelt, Indrek
    Frorip, Aleksandr
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 208 - 209
  • [25] A new monitoring system of urea in a waste dialysate for hemodialysis
    Ozaki, M.
    Okabayashi, T.
    Ishimaru, T.
    Hayashi, K.
    Hori, J.
    Nakagawa, M.
    [J]. BLOOD PURIFICATION, 2007, 25 (04) : 347 - 347
  • [26] Removal of Urea from Spent Dialysate Using an Enzymatic Method
    Bazaev N.A.
    Bizyukov I.O.
    Dorofeeva N.I.
    Putrya B.M.
    [J]. Biomedical Engineering, 2016, 50 (2) : 138 - 141
  • [27] Urea Rebound Assessment Based on UV Absorbance in Spent Dialysate
    Tomson, Ruth
    Uhlin, Fredrik
    Fridolin, Ivo
    [J]. ASAIO JOURNAL, 2014, 60 (04) : 459 - 465
  • [28] Choosing a Dialysate Sodium Concentration for Hemodialysis Patients
    Davenport, Andrew
    [J]. KIDNEY AND DIALYSIS, 2022, 2 (02): : 346 - 348
  • [29] Recycling water from spent dialysate by osmotic dilution: Impact of urea rejection of forward osmosis membrane on hemodialysis duration
    Dou, Pengjia
    Donato, Danilo
    Guo, Hong
    Zhao, Shuwei
    He, Tao
    [J]. DESALINATION, 2020, 496
  • [30] EFFECT OF DIALYSATE CALCIUM CONCENTRATION ON PLASMA PARATHYROID-HORMONE DURING HEMODIALYSIS
    MCINTOSH, CHS
    FUCHS, C
    DORN, D
    QUELLHORST, E
    HENNING, HV
    HESCH, RD
    SCHELER, F
    [J]. NEPHRON, 1977, 19 (02): : 88 - 94