The effects of patellar bracing on quadriceps EMG activity during isokinetic exercise

被引:8
|
作者
Gulling, LK [1 ]
Lephart, SM [1 ]
Stone, DA [1 ]
Irrgang, JJ [1 ]
Pincivero, DM [1 ]
机构
[1] UNIV PITTSBURGH, NEUROMUSCULAR RES LAB, SPORTS MED PROGRAM, PITTSBURGH, PA 15261 USA
关键词
patella; brace; electromyography; isokinetic;
D O I
10.3233/IES-1996-6209
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patellofemoral pain syndrome is a prevalent ailment experienced by a number of individuals participating in regular physical activity. Little information is available concerning the effects of patellofemoral bracing on the function of the extensor mechanism in patellofemoral malalignment patients. The purpose of this study was to examine the effects of patellar bracing on the extensor mechanism in relation to isokinetic exercise. Sixteen subjects exhibiting patellofemoral pain symptoms were tested on an isokinetic dynamometer with and without a patellofemoral brace. The testing procedure involved three maximal concentric/eccentric quadriceps contractions at an angular velocity of 180 degrees/s. Electromyographic (EMG) activity of the vastus medialis obliqus (VMO) and the vastus literalis (VL) were recorded during testing. Integrated EMG activity (IEMG) was analyzed by a three-way ANOVA with repeated measures (P < 0.05). The results indicated that the application of the patellar brace resulted in a significantly smaller IEMG signal than during the non-braced condition in both the VMO and VL during both concentric and eccentric contractions (P < 0.05). The IEMG signal of the VMO was found to be significantly greater than the VL regardless of test or brace condition (P < 0.05). Moreover, the IEMG signal was also found to be significantly greater during the concentric contractions than the eccentric contractions during all testing conditions (P < 0.05). The clinical implication from this study suggests that muscle activation of the VMO and VL were reduced with the use of the brace. This type of bracing may provide mechanical support to the patellofemoral joint as evidenced by the reduction in quadriceps activation during isokinetic knee extension exercise. Copyright (C) 1996 Elsevier Science Ireland Ltd.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 50 条
  • [31] Muscle architecture and EMG activity changes during isotonic and isokinetic eccentric exercises
    Guilhem, Gael
    Cornu, Christophe
    Guevel, Arnaud
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (11) : 2723 - 2733
  • [32] PATELLAR FORCES DURING ISOKINETIC KNEE EXTENSION
    NISELL, R
    ERICSON, M
    CLINICAL BIOMECHANICS, 1992, 7 (02) : 104 - 108
  • [33] The Effects Of Rest Interval On Quadriceps Torque During An Isokinetic Testing Protocol In Elderly
    Bottaro, Martim
    Russo, Andre F.
    Oliveira, Ricardo Jaco
    Barbosa, Renata Carneiro
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S267 - S267
  • [34] The effects of rest interval on quadriceps torque during an isokinetic testing protocol in elderly
    Bottaro, M
    Russo, A
    de Oliveira, RJ
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2005, 4 (03) : 285 - 290
  • [35] Isokinetic evaluation of anterior cruciate ligament reconstruction:: quadriceps tendon versus patellar tendon
    Pigozzi, F
    Di Salvo, V
    Parisi, A
    Giombini, A
    Fagnani, F
    Franceschi, WMF
    Denaro, E
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2004, 44 (03): : 288 - 293
  • [36] Effects of bracing on isokinetic torque for the chronically unstable ankle
    Hartsell, HD
    Spaulding, SJ
    JOURNAL OF SPORT REHABILITATION, 1999, 8 (02) : 83 - 98
  • [37] Patellar tracking during simulated quadriceps contraction
    Brunet, ME
    Brinker, MR
    Cook, SD
    Christakis, P
    Fong, B
    Patron, L
    O'Connor, DP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) : 266 - 275
  • [38] Agonist and antagonist moment and EMG-angle relationship during isokinetic eccentric and concentric exercise
    Kellis, E
    Baltzopoulos, V
    ISOKINETICS AND EXERCISE SCIENCE, 1996, 6 (02) : 79 - 87
  • [39] EFFECTS OF STRENGTH TRAINING ON MVC, EMG ACTIVITY, AND SHORTENING SPEED OF THE QUADRICEPS IN MAN
    BOLDOG, I
    FALUDI, J
    HORTOBAGYI, T
    MIHALYFI, P
    JOURNAL OF PHYSIOLOGY-LONDON, 1985, 369 (DEC): : P181 - P181
  • [40] The Acute Transverse Strain Response of the Patellar Tendon to Quadriceps Exercise
    Wearing, Scott C.
    Hooper, Sue L.
    Purdam, Craig
    Cook, Jill
    Grigg, Nicole
    Locke, Simon
    Smeathers, James E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (04): : 772 - 777