Electrochemical detection of Cu(I) and Cu(II) in styrene media

被引:10
|
作者
De Wael, K
Westbroek, P
De Strycker, J
Gasana, E
Temmerman, E
机构
[1] State Univ Ghent, Dept Text, B-9052 Ghent, Belgium
[2] State Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] OCAS NV, Arcelor Grp, B-9060 Zelzate, Belgium
关键词
voltammetry; ultramicro electrodes; non-aqueous solution; copper detection; tetrahexylammoniumperchloraat;
D O I
10.1016/j.microc.2004.01.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described to detect Cu(II) and COO added as bromide simultaneously in styrene solution containing tetrahexylammoniumperchloraat (THAP) as supporting electrolyte. It was found that Cu(II) and Cu(I) behave similarly in styrene and in aqueous solution. Reduction of Cu(II) and Cu(I) to metallic copper, as well as oxidation of Cu(I) to Cu(II) and the dissolution of a deposited metallic copper layer are observed. Ohmic drop problems were circumvented by adding THAP to the styrene solution and using ultramicro electrodes. The simultaneous detection of Cu(II) and Cu(I) is based on recording a cyclic voltammetric curve in a mixture of these compounds and calculating their concentration from the cathodic limiting current obtained at -0.80 V vs. RE and the anodic stripping peak corresponding to the dissolution of metallic copper. A detection limit of 2.0 x 10(-4) mol 1(-1) was obtained for both Cu(II) and Cu(I) and reproducible results were obtained concerning sensitivity and stability of the calibration curves. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 50 条
  • [31] Cu(I)/Cu(II)-catalyzed allylic amination of alkenes
    Srivastava, Radhey S.
    Bertrand, Roy, III
    Gallo, August A.
    Nicholas, Kenneth M.
    TETRAHEDRON LETTERS, 2011, 52 (27) : 3478 - 3480
  • [32] Inhibiting properties of benzimidazole films for Cu(II)/Cu(I) reduction in chloride media studied by RDE and EQCN techniques
    Scendo, M.
    Hepel, M.
    CORROSION SCIENCE, 2007, 49 (08) : 3381 - 3407
  • [33] Separation and detection of angiotensin peptides by Cu(II) complexation and capillary electrophoresis with UV and electrochemical detection
    Lacher, NA
    Garrison, KE
    Lunte, SM
    ELECTROPHORESIS, 2002, 23 (11) : 1577 - 1584
  • [34] A KINETIC-STUDY OF THE CU(II)-CU(I) SYSTEM IN CL- MEDIA AT THE GLASSY-CARBON ELECTRODE
    KIEKENS, P
    VERBEECK, RMH
    TEMMERMAN, E
    MIKROCHIMICA ACTA, 1981, 2 (1-2) : 29 - 36
  • [35] ELECTROCHEMISTRY OF THE SYSTEM CU(II)-CU(I)-CU(O) IN ACIDIFIED THIOCYANATE SOLUTIONS
    BILEWICZ, R
    STOJEK, Z
    KUBLIK, Z
    OSTERYOUNG, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 137 (01): : 77 - 87
  • [36] Inhibiting properties of benzimidazole films for Cu(II)/Cu(I) reduction in chloride media studied by RDE and EQCN techniques
    Scendo, Mieczyslaw
    Hepel, Maria
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 613 (01) : 35 - 50
  • [37] EXAFS-STUDIES OF CU(I), CU(II), CO(II) AND NI(II) STELLACYANIN
    REINHAMMAR, B
    DAHLIN, S
    FEITERS, MC
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS-JOURNAL OF THE ROYAL NETHERLANDS CHEMICAL SOCIETY, 1987, 106 (6-7): : 360 - 360
  • [38] A paper-based biomimetic device for the reduction of Cu(II) to Cu(I) - application to the sensing of Cu(II)
    Rull-Barrull, Jordi
    d'Halluin, Martin
    Le Grognec, Erwan
    Felpin, Franois-Xavier
    CHEMICAL COMMUNICATIONS, 2016, 52 (39) : 6569 - 6572
  • [39] XPS detection of unusual Cu(II) to Cu(I) transition on the surface of complexes with redox-active ligands
    Ivanova, T. M.
    Maslakov, K. I.
    Sidorov, A. A.
    Kiskin, M. A.
    Linko, R. V.
    Savilov, S. V.
    Lunin, V. V.
    Eremenko, I. L.
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2020, 238
  • [40] COPOLYMERIZATION OF STYRENE WITH ZN(II), CO(II), NI(II) AND CU(II) ACRYLATES
    WOJTCZAK, Z
    GRONOWSKI, A
    MAKROMOLEKULARE CHEMIE-MACROMOLECULAR CHEMISTRY AND PHYSICS, 1985, 186 (01): : 139 - 144