摘要
An earlier study evaluated the physical performance of the Swirling Aerosol Collector, also known as the "BioSampler," and found it to have several advantages over the widely used AGI-30 impinger when tested with inert test particles. The present study was Focused on the physical and biological performance with laboratory-aerosolized microorganisms. The results showed that the BioSampler has better physical collection efficiency for B. subtilis and P. fluororescens than the AGI-30 when water was used as the collection fluid and the sampling how rate ranged from 8.5 L min (- 1) to the standard 12.5 L min (- 1) Additionally, the BioSampler provided equivalent or better microbial recovery for the 2 species than the AGI-30 did. The swirling motion of the collection liquid in the BioSampler generates very few bubbles and therefore causes minimal reentrainment of already collected microorganisms. In contrast to the AGI-30, the BioSampler can be used very effectively with nonevaporating liquids, such as mineral oil or glycerol. Mineral oil was found to be a suitable collection fluid for culture analysis, whereas glycerol can be used only for nonculture assays, such as the polymerase chain reaction. By using a more viscous, nonevaporating fluid, the BioSampler can be used for long-term sampling of low airborne bacterial concentrations, while the AGI-30 impinger, filled with a standard evaporating fluid, can only be used for up to about 30 min.
引用
收藏
页码:184 / 196
页数:13
相关论文
共 50 条
  • [1] Collection of airborne microorganisms by electrostatic precipitation
    Aerosol Research and Exposure Assessment Laboratory, Department of Environmental Health, University of Cincinnati, P.O. Box 670056, Cincinnati
    OH
    45267-0056, United States
    不详
    WV
    26505, United States
    不详
    Aerosol Sci. Technol., 2 (127-144):
  • [2] Collection of airborne microorganisms by electrostatic precipitation
    Mainelis, G
    Grinshpun, SA
    Willeke, K
    Reponen, T
    Ulevicius, V
    Hintz, PJ
    AEROSOL SCIENCE AND TECHNOLOGY, 1999, 30 (02) : 127 - 144
  • [3] Collection of airborne microorganisms by a new electrostatic precipitator
    Mainelis, G
    Adhikari, A
    Willeke, K
    Lee, SA
    Reponen, T
    Grinshpun, SA
    JOURNAL OF AEROSOL SCIENCE, 2002, 33 (10) : 1417 - 1432
  • [4] Filtration of airborne microorganisms: Collection and reaerosolization characteristics
    Willeke, K
    Qian, YG
    ADVANCES IN FILTRATION AND SEPARATION TECHNOLOGY, VOL 11 1997, 1997, : 396 - 396
  • [6] NEW TECHNIQUE FOR THE COLLECTION AND ISOLATION OF AIRBORNE MICROORGANISMS
    OCONNELL, DC
    WIGGIN, NJB
    PIKE, GF
    SCIENCE, 1960, 131 (3397) : 359 - 360
  • [7] Collection of airborne microorganisms by a new electrostatic precipitator
    Mainelis, G. (mainelis@envsci.rutgers.edu), 1600, Elsevier Ltd (33):
  • [8] Collection of airborne microorganisms: Advantages and disadvantages of different methods
    Grinshpun, S.A.
    Willeke, K.
    Ulevicius, V.
    Donnelly, J.
    Lin, X.
    Mainelis, G.
    Journal of Aerosol Science, 1996, 27 (Suppl 1):
  • [9] An automatic Organic Aerosol Samplers for continuous Sampling of airborne Microorganisms
    Clauss, M.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (04): : 133 - 136
  • [10] Collection of airborne microorganisms into liquid by bubbling through porous medium
    Agranovski, IE
    Agranovski, V
    Grinshpun, SA
    Reponen, T
    Willeke, K
    AEROSOL SCIENCE AND TECHNOLOGY, 2002, 36 (04) : 502 - 509