Noninvasively collected sweat via clinically relevant procedure can be used for assessing the human condition, particularly for monitoring of diabetes and hypoxia. Positive correlations in variation rates, claimed as sufficient requirements for diagnostics, between glucose and lactate concentrations in sweat and the corresponding values in blood are shown. Continuous monitoring of human condition is possible only with the use of flow-through wearable devices providing a delivery of sweat to the biosensor almost immediately after excretion. Owing to both low sweat glucose content and inactivation of platinum by sweat components, the use of Prussian blue-based biosensors for wearable devices is preferable. Operation of the latter in power generation mode allows significant noise reduction and clear readout of the signal. Evaluating blood glucose through sweat analysis upon glucose tolerance test, we clearly show that humans can actually be monitored reliably via noninvasive approach.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [31] Miniaturized flow-through sensor array for methane fermentation monitoring
    Ciosek, Patrycja
    Buczkowska, Agnieszka
    Witkowska, Emilia
    Wroblewski, Wojciech
    Zamojska, Anna
    Szewczyk, Krzysztof
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1502 - +
  • [32] A flow-through reactor with an infinite sink for monitoring desorption processes
    Freese, D
    Weidler, PG
    Grolimund, D
    Sticher, H
    JOURNAL OF ENVIRONMENTAL QUALITY, 1999, 28 (02) : 537 - 543
  • [33] Flow-through stripping chronopotentiometry for the monitoring of mercury in waste waters
    Beinrohr, E
    Dzurov, J
    Annus, J
    Broekaert, JAC
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (02): : 201 - 204
  • [34] Flow-through stripping chronopotentiometry for the monitoring of mercury in waste waters
    E. Beinrohr
    J. Dzurov
    J. Annus
    J. A. C. Broekaert
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 201 - 204
  • [35] Wearable sweat biosensors on textiles for health monitoring
    Yuqing Shi
    Ziyu Zhang
    Qiyao Huang
    Yuanjing Lin
    Zijian Zheng
    Journal of Semiconductors, 2023, 44 (02) : 14 - 27
  • [36] Flexible and Wearable Biosensors for Monitoring Health Conditions
    Song, Zhimin
    Zhou, Shu
    Qin, Yanxia
    Xia, Xiangjiao
    Sun, Yanping
    Han, Guanghong
    Shu, Tong
    Hu, Liang
    Zhang, Qiang
    BIOSENSORS-BASEL, 2023, 13 (06):
  • [37] Editorial on "Wearable biosensors for personalized health monitoring"
    Gao, Wei
    TALANTA, 2021, 234
  • [38] Wearable sweat biosensors on textiles for health monitoring
    Yuqing Shi
    Ziyu Zhang
    Qiyao Huang
    Yuanjing Lin
    Zijian Zheng
    Journal of Semiconductors, 2023, (02) : 14 - 27
  • [39] Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring
    Duan, Haowei
    Peng, Shuhua
    He, Shuai
    Tang, Shi-Yang
    Goda, Keisuke
    Wang, Chun H.
    Li, Ming
    ADVANCED SCIENCE, 2025, 12 (02)
  • [40] Wearable Biosensors Studied for Clinical Monitoring and Treatment
    Kuehn, Bridget M.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (03): : 255 - 257