Accurate and efficient amino acid analysis for protein quantification using hydrophilic interaction chromatography coupled tandem mass spectrometry

被引:63
|
作者
Kambhampati, Shrikaar [1 ]
Li, Jia [1 ]
Evans, Bradley S. [1 ]
Allen, Doug K. [1 ,2 ]
机构
[1] Donald Danforth Plant Sci Ctr, St Louis, MO 63132 USA
[2] ARS, USDA, St Louis, MO USA
基金
美国农业部; 美国国家科学基金会;
关键词
HILIC; Chromatography; Isobaric compounds; Amino acids; Protein hydrolysis; Protein quantification; LC-MS; MS; Soybeans; Isotopes; PERFORMANCE LIQUID-CHROMATOGRAPHY; RAPID QUANTIFICATION; MS/MS ASSAY; HYDROLYSIS; QUANTITATION; IDENTIFICATION; METHIONINE; EXTRACTION; TRYPTOPHAN; SEPARATION;
D O I
10.1186/s13007-019-0430-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
BackgroundMethods used to quantify protein from biological samples are often inaccurate with significant variability that requires care to minimize. The errors result from losses during protein preparation and purification and false detection of interfering compounds or elements. Amino acid analysis (AAA) involves a series of chromatographic techniques that can be used to measure protein levels, avoiding some difficulties and providing specific compositional information. However, unstable derivatives, that are toxic and can be costly, incomplete reactions, inadequate chromatographic separations, and the lack of a single hydrolysis method with sufficient recovery of all amino acids hinder precise protein quantitation using AAA.ResultsIn this study, a hydrophilic interaction chromatography based method was used to separate all proteinogenic amino acids, including isobaric compounds leucine and isoleucine, prior to detection by multiple reaction monitoring with LC-MS/MS. Through inclusion of commercially available isotopically labeled (C-13, N-15) amino acids as internal standards we adapted an isotopic dilution strategy for amino acid-based quantification of proteins. Three hydrolysis methods were tested with ubiquitin, bovine serum albumin, (BSA), and a soy protein biological reference material (SRM 3234; NIST) resulting in protein estimates that were 86-103%, 82-94%, and 90-99% accurate for the three protein samples respectively. The methane sulfonic acid hydrolysis approach provided the best recovery of labile amino acids including: cysteine, methionine and tryptophan that are challenging to accurately quantify.ConclusionsAccurate determination of protein quantity and amino acid composition in heterogeneous biological samples is non-trivial. Recent advances in chromatographic phases and LC-MS/MS based methods, along with the availability of isotopic standards can minimize difficulties in analysis and improve protein quantitation. A robust method is described for high-throughput protein quantification and amino acid compositional analysis. Since accurate measurement of protein quality and quantity are a requirement for many biological studies that relate to crop improvement or more generally, our understanding of metabolism in living systems, we envision this method will have broad applicability.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Challenges in Analysis of Hydrophilic Metabolites Using Chromatography Coupled with Mass Spectrometry
    Qingyu Hu
    Huiru Tang
    Yulan Wang
    [J]. Journal of Analysis and Testing, 2020, 4 : 140 - 162
  • [42] Challenges in Analysis of Hydrophilic Metabolites Using Chromatography Coupled with Mass Spectrometry
    Hu, Qingyu
    Tang, Huiru
    Wang, Yulan
    [J]. JOURNAL OF ANALYSIS AND TESTING, 2020, 4 (03) : 140 - 162
  • [43] Accurate, sensitive and rapid determination of perchlorate in tea by hydrophilic interaction chromatography-tandem mass spectrometry
    Wang, Chen
    Chen, Hongping
    Zhu, Li
    Liu, Xin
    Lu, Chengyin
    [J]. ANALYTICAL METHODS, 2020, 12 (28) : 3592 - 3599
  • [44] Quantification of Total and Free Carnitine in Human Plasma by Hydrophilic Interaction Liquid Chromatography Tandem Mass Spectrometry
    Sowell, John
    Fuqua, Megan
    Wood, Tun
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (06) : 463 - 468
  • [45] Determination of neomycin by LC-tandem mass spectrometry using hydrophilic interaction chromatography
    Oertel, R
    Renner, U
    Kirch, W
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (03) : 633 - 638
  • [46] Quantification of ondansetron, granisetron and tropisetron in goat plasma using hydrophilic interaction liquid chromatography-solid phase extraction coupled with hydrophilic interaction liquid chromatography-triple quadrupole tandem mass spectrometry
    Huang, Cunying
    Wan, Huihui
    Zhang, Jing
    Zhong, Hongmin
    Li, Juan
    Sun, YuMing
    Wang, Qing
    Zhang, Hua
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1095 : 50 - 58
  • [47] Hydrophilic interaction liquid chromatography/tandem mass spectrometry for the analysis of diallyldimethylammonium chloride in water
    Esparza, X.
    Moyano, E.
    Ventura, F.
    Galceran, M. T.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (02) : 379 - 387
  • [48] Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography–tandem mass spectrometry
    Alexander L. N. van Nuijs
    Isabela Tarcomnicu
    Lieven Bervoets
    Ronny Blust
    Philippe G. Jorens
    Hugo Neels
    Adrian Covaci
    [J]. Analytical and Bioanalytical Chemistry, 2009, 395 : 819 - 828
  • [49] Analysis of plant nucleotide sugars by hydrophilic interaction liquid chromatography and tandem mass spectrometry
    Ito, Jun
    Herter, Thomas
    Baidoo, Edward E. K.
    Lao, Jeemeng
    Vega-Sanchez, Miguel E.
    Smith-Moritz, A. Michelle
    Adams, Paul D.
    Keasling, Jay D.
    Usadel, Bjoern
    Petzold, Christopher J.
    Heazlewood, Joshua L.
    [J]. ANALYTICAL BIOCHEMISTRY, 2014, 448 : 14 - 22
  • [50] Determination of metoclopramide in human plasma using hydrophilic interaction chromatography with tandem mass spectrometry
    Lee, Hye Won
    Ji, Hye Young
    Kim, Hoe Yoon
    Park, Eun-Seok
    Lee, Kang Choon
    Lee, Hye Suk
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (18-19): : 1716 - 1720