Performance enhancement of an air-coupled multiple moving membrane capacitive micromachined ultrasonic transducer using an optimized middle plate configuration

被引:1
|
作者
Emadi, Arezoo [1 ]
Buchanan, Douglas [1 ]
机构
[1] Univ Manitoba, Fac Engn, Dept Elect & Comp Engn, 75 Chancellors Circle, Winnipeg, MB R3T 5VR, Canada
来源
基金
加拿大自然科学与工程研究理事会;
关键词
middle deflectable plate; multiple moving membrane capacitive micromachined ultrasonic transducer; resonant frequency; sacrificial layer; FABRICATION; ARRAYS;
D O I
10.1117/1.JMM.15.4.045004
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A multiple moving membrane capacitive micromachined ultrasonic transducer has been developed. This transducer cell structure includes a second flexible plate suspended between the transducer top plate and the fixed bottom electrode. The added plate influences the transducer top plate deflection map and, therefore, the transducer properties. Three series of individual air-coupled, dual deflectable plate transducers and two 1 x 27 element transducer arrays were fabricated using multiuser microelectromechanical systems (MEMS) processes (MUMPs). Each set of transducers included devices with middle plate radii from 22% to 65% of the corresponding transducer top plate radius. The effect of the transducer middle plate configuration has been investigated. Electrical, optical, and acoustic characterizations were conducted and the results were compared with the simulation findings. It was found that the transducer top plate amplitude of vibration is significantly enhanced with a wider middle deflectable plate. The electrical and optical measurement results are shown to be in good agreement with simulation results. The acoustic measurement results indicated a 37% increase in the amplitude of transmitted signal by the 1-MHz air-couple transducer when its middle plate radius was increased by 35%. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Air-coupled capacitive micromachined transducer array for non-contact Lamb wave detection
    Zhang, Hui
    Li, Shaojie
    Wang, Junjie
    Ma, Yongshuai
    Sun, Jing
    Liu, Si
    Wang, Zhuochen
    Huang, Xinjing
    Rui, Xiaobo
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 355
  • [22] Capacitive micromachined ultrasonic transducers based on annular cell geometry for air-coupled applications
    Na, Shuai
    Chen, Albert I. H.
    Wong, Lawrence L. P.
    Li, Zhenhao
    Macecek, Mirek
    Yeow, John T. W.
    ULTRASONICS, 2016, 71 : 152 - 160
  • [23] Numerical modelling for the optimization of multi-element, capacitive, ultrasonic, air-coupled transducer
    Zhang, D.
    Renier, M.
    Castaings, M.
    11TH ANGLO-FRENCH PHYSICAL ACOUSTICS CONFERENCE (AFPAC 2012), 2013, 457
  • [24] Investigation on Characteristics of a MXenes-Based Air-Coupled Capacitive Ultrasonic Transducer Array
    Zhang, Qing
    Luo, Cizhu
    Wang, Ranxu
    Guo, Xinhua
    IEEE SENSORS JOURNAL, 2023, 23 (23) : 28696 - 28705
  • [25] WIDEBAND AIR-COUPLED PZT PIEZOELECTRIC MICROMACHINED ULTRASONIC TRANSDUCER THROUGH DC BIAS TUNING
    Kusano, Yuri
    Wang, Qi
    Rudy, Ryan Q.
    Polcawich, Ronald G.
    Horsley, David A.
    30TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2017), 2017, : 1204 - 1207
  • [26] Lumped element modeling of air-coupled capacitive micromachined ultrasonic transducers with annular cell geometry
    Na, Shuai
    Wong, Lawrence L. P.
    Chen, Albert I. H.
    Li, Zhenhao
    Macecek, Mirek
    Yeow, John T. W.
    ULTRASONICS, 2017, 76 : 19 - 27
  • [27] A Two-Port Multiple Moving Membrane Capacitive Micromachined Ultrasonic Transducer with Reduced Effective Height and Enhanced Sensitivity
    Butrus, Rima
    Nazemi, Haleh
    Nathani, Muhammad Umair
    Karmarkar, Rohit
    Buchanan, Douglas
    Emadi, Arezoo
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [28] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Univ of Strathclyde, Glasgow, United Kingdom
    IEEE Trans Ultrason Ferroelectr Freq Control, 6 (1549-1558):
  • [29] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Galbraith, W
    Hayward, G
    Benny, G
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 917 - 920
  • [30] Development of a PVDF membrane hydrophone for use in air-coupled ultrasonic transducer calibration
    Galbraith, W
    Hayward, G
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (06) : 1549 - 1558