Sequential-Digital Image Correlation for Mapping Human Posterior Sclera and Optic Nerve Head Deformation

被引:19
|
作者
Pyne, Jeffrey D. [1 ]
Genovese, Katia [2 ]
Casaletto, Luciana [2 ]
Vande Geest, Jonathan P. [3 ]
机构
[1] Univ Arizona, BIO5 Inst, Dept Aerosp & Mech Engn, Tucson, AZ 85721 USA
[2] Univ Basilicata, Sch Engn, I-85100 Potenza, Italy
[3] Univ Arizona, BIO5 Inst, Dept Biomed Engn, Dept Aerosp & Mech Engn,Biomed Engn Grad Interdis, Tucson, AZ 85721 USA
关键词
ocular biomechanics; S-DIC; stereo-DIC; sequential DIC; optic nerve head deformation; glaucoma; posterior sclera; inflation test; IN-VITRO QUANTIFICATION; SURFACE STRAIN FIELDS; LAMINA-CRIBROSA; BIOMECHANICAL STRUCTURE; ERROR ASSESSMENT; GLAUCOMA; STRESS; SYSTEM; TISSUE; MOTION;
D O I
10.1115/1.4026224
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Optic nerve head (ONH) deformations may be involved in the onset or further development of glaucoma, including in patients with relatively normal intraocular pressures (IOPs). Characterizing posterior scleral deformations over physiological pressures may provide a better understanding of how changes in IOP lead to changes in the mechanical environment of the ONH and possibly retinal ganglion cell death. Pressure inflation measurement test protocols are commonly used to measure deformation of the peripapillary sclera with full-field noncontact optical methods. The purpose of this work was to develop and validate a new sequential 3D digital image correlation (S-DIC) approach for quantification of posterior scleral pressure induced deformation that improves z (in-depth) resolution of the DIC measurement without losing in-plane sensitivity, while also being able to contour and map deformations of the complex-shaped ONH. Our approach combines two orthogonal axes of parallax with standard 3D DIC methods using a single high-resolution camera. The enhanced capabilities of S-DIC with respect to standard 3D DIC has been demonstrated by carrying out a complete benchmark for shape, deformation, and strain measurement on an object of known complex geometry. Our S-DIC method provided a reconstruction accuracy of 0.17% and an uncertainty in z-position measurement of 8 mu m. The developed methodology has also been applied to a human posterior scleral shell, including the full peripapillary sclera and optic nerve. The relatively inexpensive S-DIC approach may provide new information on the biomechanical deformations of the optic nerve head and, thus, the death of retinal ganglion cells in primary open angle glaucoma.
引用
收藏
页数:12
相关论文
共 44 条
  • [21] The acute effects of cigarette smoking on human optic nerve head and posterior fundus circulation in light smokers
    Yasuhiro Tamaki
    Makoto Araie
    Miyuki Nagahara
    Ken Tomita
    Masao Matsubara
    Eye, 2000, 14 : 67 - 72
  • [22] The acute effects of cigarette smoking on human optic nerve head and posterior fundus circulation in light smokers
    Tamaki, Y
    Araie, M
    Nagahara, M
    Tomita, K
    Matsubara, M
    EYE, 2000, 14 (1) : 67 - 72
  • [23] Digital image correlation method based on quasi-conformal mapping for large deformation measurement
    Ye, Jingchen
    Ji, Hongwei
    Zhang, Xiaochuan
    OPTICS AND LASERS IN ENGINEERING, 2022, 153
  • [24] Optical microangiography provides correlation between microstructure and microvasculature of optic nerve head in human subjects
    An, Lin
    Johnstone, Murray
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [25] DIGITAL IMAGE-ANALYSIS OF OPTIC-NERVE HEAD PALLOR AS A DIAGNOSTIC-TEST FOR EARLY GLAUCOMA
    ASSAD, A
    CAPRIOLI, J
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1992, 230 (05) : 432 - 436
  • [26] Statistic image mapping: A new statistical approach for detecting structural change in series of optic nerve head topography images
    Garway-Heath, DF
    Patterson, AJ
    Artes, PH
    Strouthidis, NG
    Crabb, DP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [27] In-vivo deformation measurements of the human heart by 3D Digital Image Correlation
    Hokka, Mikko
    Mirow, Nikolas
    Nagel, Horst
    Irqsusi, Marc
    Vogt, Sebastian
    Kuokkala, Veli-Tapani
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2217 - 2220
  • [28] Full-Field Deformation Measurement and Crack Mapping on Confined Masonry Walls Using Digital Image Correlation
    R. Ghorbani
    F. Matta
    M.A. Sutton
    Experimental Mechanics, 2015, 55 : 227 - 243
  • [29] Full-Field Deformation Measurement and Crack Mapping on Confined Masonry Walls Using Digital Image Correlation
    Ghorbani, R.
    Matta, F.
    Sutton, M. A.
    EXPERIMENTAL MECHANICS, 2015, 55 (01) : 227 - 243
  • [30] Cost-effective instrumentation for quantitative depth measurement of optic nerve head using stereo fundus image pair and image cross correlation techniques
    Vieira de Carvalho, Luis Alberto
    Carvalho, Valeria
    OPHTHALMIC TECHNOLOGIES XXIV, 2014, 8930