Sequential-Digital Image Correlation for Mapping Human Posterior Sclera and Optic Nerve Head Deformation

被引:19
|
作者
Pyne, Jeffrey D. [1 ]
Genovese, Katia [2 ]
Casaletto, Luciana [2 ]
Vande Geest, Jonathan P. [3 ]
机构
[1] Univ Arizona, BIO5 Inst, Dept Aerosp & Mech Engn, Tucson, AZ 85721 USA
[2] Univ Basilicata, Sch Engn, I-85100 Potenza, Italy
[3] Univ Arizona, BIO5 Inst, Dept Biomed Engn, Dept Aerosp & Mech Engn,Biomed Engn Grad Interdis, Tucson, AZ 85721 USA
关键词
ocular biomechanics; S-DIC; stereo-DIC; sequential DIC; optic nerve head deformation; glaucoma; posterior sclera; inflation test; IN-VITRO QUANTIFICATION; SURFACE STRAIN FIELDS; LAMINA-CRIBROSA; BIOMECHANICAL STRUCTURE; ERROR ASSESSMENT; GLAUCOMA; STRESS; SYSTEM; TISSUE; MOTION;
D O I
10.1115/1.4026224
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Optic nerve head (ONH) deformations may be involved in the onset or further development of glaucoma, including in patients with relatively normal intraocular pressures (IOPs). Characterizing posterior scleral deformations over physiological pressures may provide a better understanding of how changes in IOP lead to changes in the mechanical environment of the ONH and possibly retinal ganglion cell death. Pressure inflation measurement test protocols are commonly used to measure deformation of the peripapillary sclera with full-field noncontact optical methods. The purpose of this work was to develop and validate a new sequential 3D digital image correlation (S-DIC) approach for quantification of posterior scleral pressure induced deformation that improves z (in-depth) resolution of the DIC measurement without losing in-plane sensitivity, while also being able to contour and map deformations of the complex-shaped ONH. Our approach combines two orthogonal axes of parallax with standard 3D DIC methods using a single high-resolution camera. The enhanced capabilities of S-DIC with respect to standard 3D DIC has been demonstrated by carrying out a complete benchmark for shape, deformation, and strain measurement on an object of known complex geometry. Our S-DIC method provided a reconstruction accuracy of 0.17% and an uncertainty in z-position measurement of 8 mu m. The developed methodology has also been applied to a human posterior scleral shell, including the full peripapillary sclera and optic nerve. The relatively inexpensive S-DIC approach may provide new information on the biomechanical deformations of the optic nerve head and, thus, the death of retinal ganglion cells in primary open angle glaucoma.
引用
收藏
页数:12
相关论文
共 44 条
  • [1] A Sequential Digital Image Correlation Technique for Improved Strain Mapping in Pressure Inflation Tests of Posterior Sclera
    Vande Geest, Jonathan
    Pyne, Jeff
    Genovese, Katia
    Casaletto, Luciana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Measuring Deformation in the Mouse Optic Nerve Head and Peripapillary Sclera
    Nguyen, Cathy
    Midgett, Dan
    Kimball, Elizabeth C.
    Steinhart, Matthew R.
    Nguyen, Thao D.
    Pease, Mary E.
    Oglesby, Ericka N.
    Jefferys, Joan L.
    Quigley, Harry A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (02) : 721 - 733
  • [3] Regional Deformation of the Optic Nerve Head and Peripapillary Sclera During IOP Elevation
    Pavlatos, Elias
    Ma, Yanhui
    Clayson, Keyton
    Pan, Xueliang
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (08) : 3779 - 3788
  • [4] In vivo characterization of the deformation of the human optic nerve head using optical coherence tomography and digital volume correlation
    Midgett, Dan E.
    Quigley, Harry A.
    Nguyen, Thao D.
    ACTA BIOMATERIALIA, 2019, 96 : 385 - 399
  • [5] Effects of peripapillary sclera stiffening on optic nerve head deformation in a porcine eye model
    Pan, Manqi
    Chen, Zihao
    Pan, Xueliang
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] Inflation Test of Human Optic Nerve Head using Digital Volume Correlation
    Midgett, Dan E.
    Pease, Mary Ellen
    Quigley, Harry A.
    Nguyen, Thao D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [7] Inflation Test of the Human Optic Nerve Head Using Digital Volume Correlation
    Midgett, Dan E.
    Quigley, Harry A.
    Pease, Mary E.
    Franck, Christian
    Toyjanova, Jennet
    Nguyen, Thao D.
    MECHANICS OF BIOLOGICAL SYSTEMS AND MATER IALS, VOL 6, 2016, : 7 - 15
  • [8] Mapping Pulsatile Optic Nerve Head Deformation Using OCT
    Solano, Marisse Masis
    Richer, Emmanuelle
    Cheriet, Farida
    Lesk, Mark R.
    Costantino, Santiago
    OPHTHALMOLOGY SCIENCE, 2022, 2 (04):
  • [9] IOP-related Mechanical Deformation is Concentrated in the Anterior Optic Nerve Head and Peripapillary Sclera
    Kwok, Sunny
    Ma, Yanhui
    Pan, Xueliang
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [10] IOP-induced regional displacements in the optic nerve head and correlation with peripapillary sclera thickness
    Ma, Yanhui
    Kwok, Sunny
    Sun, Jiajun
    Pan, Xueliang
    Pavlatos, Elias
    Clayson, Keyton
    Hazen, Nicholas
    Liu, Jun
    EXPERIMENTAL EYE RESEARCH, 2020, 200