A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images

被引:164
|
作者
Watzke, O [1 ]
Kalender, WA [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
关键词
computed tomography; artifacts; image manipulation; correction;
D O I
10.1007/s00330-004-2263-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to improve metal artifact reduction (MAR) in X-ray computed tomography (CT) by the combination of two artifact reduction methods. The presented method constitutes an image-based weighted superposition of images processed with two known methods for MAR: linear interpolation of reprojected metal traces (LI) and multi-dimensional adaptive filtering of the raw data (MAF). Two weighting concepts were realized that take into account mean distances of image points from metal objects or additional directional components. Artifact reduction on patient data from the jaw and the hip region shows that although the application of only one of the MAR algorithms can already improve image quality, these methods have specific drawbacks. While MAF does not correct corrupted CT values, LI often introduces secondary artifacts. The corrective impact of the merging algorithm is almost always superior to the application of only one of the methods. The results obtained with directional weighting are equal to or in many cases better than those of the distance weighting scheme. Merging combines the advantages of two fundamentally different approaches to artifact reduction and can improve the quality of images that are affected by metal artifacts.
引用
收藏
页码:849 / 856
页数:8
相关论文
共 50 条
  • [41] An Image Inpainting Based Surrogate Data Strategy for Metal Artifact Reduction in CT Images
    Oehler, M.
    Buzug, T. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 651 - 654
  • [42] A Method for Assessing the Effect of Metal Artifact Reduction Algorithms on Quantitative Characteristics of CT Images
    Yu. A. Vasilev
    D. S. Semenov
    E. S. Akhmad
    O. Yu. Panina
    K. A. Sergunova
    A. V. Petraikin
    Biomedical Engineering, 2020, 54 : 285 - 288
  • [43] Evaluation of the Impact of Using TOF Technique on Metal Artifact Reduction in PET/CT Images
    Sharifpour, R.
    Ghafarian, P.
    Ay, M. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S363 - S364
  • [44] Metal Artifact Reduction in Photon-Counting Detector CT Quantitative Evaluation of Artifact Reduction Techniques
    Skornitzke, Stephan
    Mergen, Victor
    Biederer, Juergen
    Alkadhi, Hatem
    Do, Thuy D.
    Stiller, Wolfram
    Frauenfelder, Thomas
    Kauczor, Hans-Ulrich
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2024, 59 (06) : 442 - 449
  • [45] A Method for Assessing the Effect of Metal Artifact Reduction Algorithms on Quantitative Characteristics of CT Images
    Vasilev, Yu A.
    Semenov, D. S.
    Akhmad, E. S.
    Panina, O. Yu
    Sergunova, K. A.
    Petraikin, A., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2020, 54 (04): : 285 - 288
  • [46] Metal artifact reduction of orthopedics metal artifact reduction algorithm in total hip and knee arthroplasty
    Zhang, Kesong
    Han, Qing
    Xu, Xiaolin
    Jiang, Hao
    Ma, Lin
    Zhang, Yong
    Yang, Kerong
    Chen, Bingpeng
    Wang, Jincheng
    MEDICINE, 2020, 99 (11) : E19268
  • [47] Metal artifact reduction and image quality evaluation of lumbar spine CT images using metal sinogram segmentation
    Kaewlek, Titipong
    Koolpiruck, Diew
    Thongvigitmanee, Saowapak
    Mongkolsuk, Manus
    Thammakittiphan, Sastrawut
    Tritrakarn, Siri-on
    Chiewvit, Pipat
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (06) : 649 - 666
  • [48] Imaging of Arthroplasties: Improved Image Quality and Lesion Detection With Iterative Metal Artifact Reduction, a New CT Metal Artifact Reduction Technique
    Subhas, Naveen
    Polster, Joshua M.
    Obuchowski, Nancy A.
    Primak, Andrew N.
    Dong, Frank F.
    Herts, Brian R.
    Iannotti, Joseph P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (02) : 378 - 385
  • [49] CLIMAR: classified linear interpolation based metal artifact reduction for severe metal artifact reduction in x-ray CT imaging
    Yoon, Huisu
    Lee, Kyoung-Yong
    Bechwati, Ibrahim
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [50] Reduction of Metal Artifact with Dual-Energy CT: Virtual Monospectral Imaging with Fast Kilovoltage Switching and Metal Artifact Reduction Software
    Pessis, Eric
    Sverzut, Jean-Michel
    Campagna, Raphael
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (05) : 446 - 455