Glycated Albumin Measurement Using an Electrochemical Aptasensor for Screening and Monitoring of Diabetes Mellitus

被引:39
|
作者
Bunyarataphan, Sasinee [1 ]
Dharakul, Tararaj [2 ]
Fucharoen, Suthat [3 ]
Paiboonsukwong, Kittiphong [3 ]
Japrung, Deanpen [1 ]
机构
[1] NSTDA, Natl Nanotechnol Ctr NANOTEC, Pathum Thani 12120, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Immunol, Bangkok, Thailand
[3] Mahidol Univ, Inst Mol Biosci, Thalassemia Res Ctr, Salaya, Nakhon Pathom, Thailand
关键词
Electrochemistry; Aptamers; Albumin; Glycated albumin; Diabetes mellitus; CARBON; ASSAY; IMMUNOSENSOR; FRUCTOSAMINE; ORIENTATION; HEMOGLOBIN; ADSORPTION; DIAGNOSIS; LYSOZYME; PROTEIN;
D O I
10.1002/elan.201900264
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glycated albumin (GHSA) is a medium-term glycaemic control marker of diabetes, which can be used as an alternative to or together with glycated haemoglobin (HbA1c). Currently available methods for the measurement of GHSA are limited in clinical practice because they involve slow and cumbersome processes of sample preparation, proteolytic digestion, and thermal incubation, and they suffer from limited analytical performance, and/or a lack of normalization to total albumin (HSA) levels. In this paper, we developed a simple electrochemical biosensor to measure GHSA values based on two DNA aptamers that specifically bind to GHSA and HSA. We used square wave voltammetry (SWV) to measure binding of the target proteins to their specific biotinylated aptamers, which had been immobilised on separate streptavidin (STR)-modified screen-printed carbon electrodes (SPCEs), in the presence of the redox mediator ferricyanide (Fe(CN)(6)(3-)). This electrochemical aptasensing system had a detection limit of 3 ng/ml for GHSA and 0.2 mu g/ml for HSA. The results exhibited high selectivity for GHSA over other molecules present in the blood. The developed sensor was able to measure the amount of GHSA in plasma samples. A statistically significant difference was observed in the elevated plasma GHSA levels in diabetic versus non-diabetic patients. Moreover, the trends in these GHSA levels were consistent with those obtained using the HbA1c test. The sensing system reported herein could be applied as a point-of-care-testing (POCT) device for measurements of clinically relevant GHSA values.
引用
收藏
页码:2254 / 2261
页数:8
相关论文
共 50 条
  • [21] Measurement of glycated hemoglobin percentages for use in the diagnosis and monitoring of diabetes mellitus in nonhuman primates
    Dutton, CJ
    Parvin, CA
    Gronowski, AM
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2003, 64 (05) : 562 - 568
  • [22] Flexible multielectrode arrays based electrochemical aptasensor for glycated human serum albumin detection
    Zhou, Lei
    Figueroa-Miranda, Gabriela
    Chen, Song
    Neis, Marc
    Hu, Ziheng
    Zhu, Ruifeng
    Li, Yaqi
    Proempers, Michael
    Offenhaeusser, Andreas
    Mayer, Dirk
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 386
  • [23] A Review on Research Progress in the Application of Glycosylated Hemoglobin and Glycated Albumin in the Screening and Monitoring of Gestational Diabetes
    Liu, Xinyan
    Wu, Na
    Al-Mureish, Abdulrahman
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 1155 - 1165
  • [24] Glycated albumin is a better indicator for glucose estimation than glycated hemoglobin in gestational diabetes mellitus
    Xing, Haoyue
    Tang, Lei
    Chen, Qi
    Li, Ling
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2016, 32 (SUPP 2) : 13 - 14
  • [25] Clinical usefulness of glycated albumin and glycated albumin-to-glycated hemoglobin ratio of gestational diabetes mellitus in late pregnancy for predicting infant complications
    Sugawara, Daisuke
    Sato, Hiroaki
    Makita, Eishi
    Kuwata, Tomoyuki
    Takagi, Kenjiro
    Ichihashi, Ko
    PEDIATRICS AND NEONATOLOGY, 2022, 63 (03): : 239 - 246
  • [26] THE RELATIVE VALUE OF GLYCATED ALBUMIN, HEMOGLOBIN A1C AND FRUCTOSAMINE WHEN SCREENING FOR DIABETES-MELLITUS
    SHIMA, K
    ABE, F
    CHIKAKIYO, H
    ITO, N
    DIABETES RESEARCH AND CLINICAL PRACTICE, 1989, 7 (04) : 243 - 250
  • [27] Electrochemical Immunoassay for Determination of Glycated Albumin using Nanozymes
    Choi, Hyun
    Son, Seong Eun
    Hur, Won
    Tran, Van-Khue
    Lee, HanBeen
    Park, Yosep
    Han, Do Kyoung
    Seong, Gi Hun
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [28] Electrochemical Immunoassay for Determination of Glycated Albumin using Nanozymes
    Hyun Choi
    Seong Eun Son
    Won Hur
    Van-Khue Tran
    Han Been Lee
    Yosep Park
    Do Kyoung Han
    Gi Hun Seong
    Scientific Reports, 10
  • [29] Diagnostic value of glycated haemoglobin as a screening test for diabetes mellitus
    Hu, Y.
    Liu, W.
    Chen, Y.
    Zhang, M.
    Li, S.
    Liu, X.
    Han, T.
    Ji, L.
    DIABETOLOGIA, 2009, 52 : S122 - S122
  • [30] Simultaneous electrochemical detection of glycated and human serum albumin for diabetes management
    Dastidar, Monalisha Ghosh
    Murugappan, Krishnan
    Nisbet, David R.
    Tricoli, Antonio
    BIOSENSORS & BIOELECTRONICS, 2024, 246