Computer tomography-guided core biopsies in a county hospital in Sweden: Complication rate and diagnostic yield

被引:13
|
作者
Branden, Eva [1 ,2 ,3 ]
Wallgren, Stig [4 ]
Hogberg, Hans [2 ,5 ]
Koyi, Hirsh [1 ,2 ,3 ]
机构
[1] Gavle Cent Hosp, Dept Resp Med, S-80187 Gavle, Sweden
[2] Uppsala Univ, Cty Council Gavleborg, Ctr Res & Dev, Uppsala, Sweden
[3] Karolinska Inst, Stockholm, Sweden
[4] Gavle Cent Hosp, Dept Radiol, S-80187 Gavle, Sweden
[5] Cty Council Gavleborg, Dept Publ Hlth Med, Gavle, Sweden
关键词
Core biopsies; emphysema; FEV1; hemorrhage; pneumothorax; CELL LUNG-CANCER; NEEDLE-BIOPSY; LESIONS; PNEUMOTHORAX; RISK;
D O I
10.4103/1817-1737.134069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Core biopsies are valuable in obtaining sufficient tissue to ensure diagnosis of diseases in the thorax. OBJECTIVE: To evaluate the complication rate and the diagnostic yield in computer tomography (CT)-guided core biopsies performed in a county hospital in Sweden. METHODS: Medical journals, spirometry results, pathology reports and CT scans were reviewed in 463 consecutive cases, where a transthoracic core biopsy was performed between January 2005 and December 2010. Of these 380 (82%) were lung lesions, 48 (10%) were mediastinal lesions and 35 (8%) were pleural lesions. RESULTS: All patients underwent a chest X-ray 4 hours post-biopsy and pneumothorax was seen in 156/463 (34%) patients: 137 after lung biopsy and 17 after mediastinal biopsy. Chest tube insertion was required for 27 (17%) of these patients (6% of all core biopsies). Small intraparenchymal hemorrhages and hemoptysis were observed with subjective difficulty in one case. The diagnostic yield for the 463 patients was 212 (46%) cases of lung cancer, 188 (41%) benign lesions and 39 (8%) pulmonary metastases. CONCLUSIONS: A transthoracic core biopsy ensures diagnosis with a low complication rate and is suitable as an outpatient procedure. An increased risk for pneumothorax was observed when the biopsied lesion was small or when emphysema was in the path of the biopsy needle. Reduced lung function pre-biopsy or emphysema in the path of the biopsy needle increased the need for chest tube treatment of pneumothorax. A CT-guided core biopsy is safe and applicable in a county hospital.
引用
收藏
页码:149 / 153
页数:5
相关论文
共 50 条
  • [41] Accuracy and adequacy of computed tomography-guided lung biopsies: experience from a community hospital (Vol 115, pg 592, 2015)
    Florentine, B. D.
    Helton, R. J.
    Mitchell, M. M.
    Schmidt, K. E.
    Kozlov, D. B.
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 2015, 115 (11): : 646 - 646
  • [42] Pneumothorax Rate and Diagnostic Adequacy of Computed Tomography-guided Lung Nodule Biopsies Performed With 18 G Versus 20 G Needles A Cross-Sectional Study
    Kolderman, Nathan C.
    Cheti, Dev R.
    Hasbrook, Connor D.
    Forsyth, Andrew J.
    Coffey, Mary P.
    Nair, Girish B.
    Al-Katib, Sayf A.
    JOURNAL OF THORACIC IMAGING, 2020, 35 (04) : 265 - 269
  • [43] Diagnostic yield and safety of medical thoracoscopic versus computed tomography-guided percutaneous tru-cut pleural biopsy
    Abo El-Magd, Gehan H.
    Abouissa, Ahmad H.
    Abbas, Ibrahim
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2020, 69 (01): : 119 - 126
  • [44] Computed Tomography-Guided Fine Needle Aspiration and Needle Core Biopsy: Which Specimen Type Yields Diagnostic Results?
    Kikuchi, Y.
    Larsen, D.
    Sayage-Rabie, L.
    MODERN PATHOLOGY, 2012, 25 : 95A - 95A
  • [45] Computed Tomography-Guided Fine Needle Aspiration and Needle Core Biopsy: Which Specimen Type Yields Diagnostic Results?
    Kikuchi, Y.
    Larsen, D.
    Sayage-Rabie, L.
    LABORATORY INVESTIGATION, 2012, 92 : 95A - 95A
  • [46] Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidneys using a 14-gauge Biopty gun
    Preda, A
    Van Dijk, LC
    Van Oostaijen, JA
    Pattynama, PMT
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 527 - 530
  • [47] Complication rate and diagnostic yield of 515 consecutive ultrasound-guided biopsies of renal allografts and native kidneys using a 14-gauge Biopty gun
    Anda Preda
    Lucas C. Van Dijk
    Jacques A. Van Oostaijen
    Peter M. Pattynama
    European Radiology, 2003, 13 : 527 - 530
  • [48] The Impact of Rapid On-site Evaluation on Diagnostic Performance of Computed Tomography-Guided Core Needle Biopsy in Lung Cancer
    Magnini, Andrea
    Lorini, Chiara
    Calistri, Linda
    Calcagni, Francesca
    Giuntoli, Federico
    Foxi, Prassede
    Nardi, Cosimo
    Colagrande, Stefano
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (05) : 803 - 809
  • [49] Ultrasound-guided percutaneous biopsy of thoracic lesions: high diagnostic yield and low complication rate
    Portela-Oliveira, E.
    Souza, C. A.
    Gupta, A.
    Bayanati, H.
    Inacio, J.
    Rakhra, K.
    CLINICAL RADIOLOGY, 2021, 76 (04) : 281 - 286
  • [50] Immediate Cytology Improves Accuracy and Decreases Complication Rate in Real-time Computed Tomography-guided Needle Lung Biopsy
    Tachibana, Keisei
    Nakazato, Yoshimasa
    Tsuchida, Shigeru
    Kazama, Toshifumi
    Minato, Koichi
    Yoshida, Tsutomu
    Fujita, Atsushi
    Horikoshi, Hiroyuki
    Tanaka, Ryota
    Iijima, Misa
    Goya, Tomoyuki
    DIAGNOSTIC CYTOPATHOLOGY, 2013, 41 (12) : 1063 - 1068