A system for the measurement of electron stopping powers: proof of principle using a pure β-emitting source

被引:3
|
作者
Roy, Timothy [1 ,2 ]
Tessier, Frederic [1 ]
McEwen, Malcolm [1 ]
机构
[1] Natl Res Council Canada, Measurement Sci & Stand, Ottawa, ON, Canada
[2] Univ Ottawa, Ottawa, ON, Canada
关键词
POLYSTYRENE; RATIOS;
D O I
10.1016/j.radphyschem.2018.03.006
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The accuracy of the electron stopping powers of elements and compounds is of great importance to medical dosimetry, radiation therapy, and radiation transport simulations. This paper summarises the commissioning of a new high purity Germanium (HPGe) detector and presents a feasibility study confirming the suitability of a method to determine electron stopping power data. A high-efficiency, HPGe detector was commissioned and found to match the manufacturer's performance specifications. A simple experiment was designed to obtain spectra acquired from a Sr-90/Y-90 radioactive check source with varying thicknesses of absorber (Al and Cu foils) placed between the source and the detector. The entire experimental arrangement was simulated using the EGSnrc radiation transport system. The Monte Carlo model of the detector accurately replicated the detector response to electrons and a quantitative analysis showed that the difference between the simulated and measured spectra was less than 1.5%, using the standard tabulated ICRU 37 stopping power data for the simulations. Based on the experiment with the low-energy Sr-90/Y-90 source, it is anticipated that this method can be used with a well-characterized quasi-monoenergetic electron beam, as available from a research linear accelerated to yield accurate measurements to validate current tabulated stopping power data.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 50 条
  • [21] Epidural pressure measurement using a fiber-optic sensor(proof-of-principle in vivo animal trial)
    Susanne Barz
    Marvin Friedemann
    Sebastian Voigt
    Markus Melloh
    Thomas Barz
    Animal Models and Experimental Medicine, 2024, 7 (05) : 769 - 776
  • [22] Proof-of-principle demonstration of measurement-device-independent quantum key distribution using polarization qubits
    Ferreira da Silva, T.
    Vitoreti, D.
    Xavier, G. B.
    do Amaral, G. C.
    Temporao, G. P.
    von der Weid, J. P.
    PHYSICAL REVIEW A, 2013, 88 (05):
  • [23] Epidural pressure measurement using a fiber-optic sensor (proof-of-principle in vivo animal trial)
    Barz, Susanne
    Friedemann, Marvin
    Voigt, Sebastian
    Melloh, Markus
    Barz, Thomas
    ANIMAL MODELS AND EXPERIMENTAL MEDICINE, 2024, 7 (05) : 769 - 776
  • [24] Wireless fast-scan cyclic voltammetry measurement of histamine using WINCS - a proof-of-principle study
    Chang, Su-Youne
    Jay, Taylor
    Munoz, Joel
    Kim, Inyong
    Lee, Kendall H.
    ANALYST, 2012, 137 (09) : 2158 - 2165
  • [25] High-precision measurement of electronic stopping powers for heavy ions using high-resolution time-of-flight spectrometry
    Zhang, YW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 196 (1-2): : 1 - 15
  • [26] Photon activation analysis: a proof of principle using a NIST sediment standard and an electron accelerator at Rensselaer Polytechnic Institute
    Ni, J
    Block, RC
    Xu, XG
    APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 535 - 540
  • [27] Technical Note: Implications of using EGSnrc instead of EGS4 for extracting electron stopping powers from measured energy spectra
    Tessier, Frederic
    Ross, Carl K.
    MEDICAL PHYSICS, 2021, 48 (04) : 1996 - 2003
  • [28] Instantaneous electron beam emittance measurement system based. on the optical transition radiation principle
    Jiang Xiao-Guo
    Wang Yuan
    Zhang Kai-Zhi
    Yang Guo-Jun
    Shi Jin-Shui
    Deng Jian-Jun
    Li Jin
    CHINESE PHYSICS C, 2014, 38 (01)
  • [29] THE DESIGN METHOD FOR A CONTROL PROCESS FOR MULTIPLE SOURCE ELECTRON-CYCLOTRON RESONANCE HEATING FOR THE ELMO BUMPY TORUS - PROOF OF PRINCIPLE DEVICE
    WEAVER, TL
    NUCLEAR TECHNOLOGY-FUSION, 1983, 4 (02): : 1442 - 1447
  • [30] Proof-of-principle demonstration of vertical-gravity-gradient measurement using a single-proof-mass double-loop atom interferometer
    Perrin, I
    Bidel, Y.
    Zahzam, N.
    Blanchard, C.
    Bresson, A.
    Cadoret, M.
    PHYSICAL REVIEW A, 2019, 99 (01)