Automated Instead of Manual Treatment Planning? A Plan Comparison Based on Dose-Volume Statistics and Clinical Preference

被引:36
|
作者
Vanderstraeten, Barbara [1 ,2 ]
Goddeeris, Bruno [1 ]
Vandecasteele, Katrien [1 ,2 ]
van Eijkeren, Marc [1 ,2 ]
De Wagter, Carlos [1 ,2 ]
Lievens, Yolande [1 ,2 ]
机构
[1] Ghent Univ Hosp, Dept Radiotherapy Oncol, De Pintelaan 185 RTP, B-9000 Ghent, Belgium
[2] Univ Ghent, Dept Radiotherapy & Expt Canc Res, Ghent, Belgium
关键词
MODULATED RADIATION-THERAPY; STEREOTACTIC BODY RADIOTHERAPY; AT-RISK; IMRT; HEAD; QUALITY; GENERATION; VMAT; OPTIMIZATION; VALIDATION;
D O I
10.1016/j.ijrobp.2018.05.063
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Automated planning aims to speed up treatment planning and improve plan quality. We compared manual planning with automated planning for lung stereotactic body radiation therapy based on dose-volume histogram statistics and clinical preference. Methods and Materials: Manual and automated intensity modulated radiation therapy plans were generated for 56 patients by use of software developed in-house and Pinnacle 9.10 Auto-Planning, respectively. Optimization times were measured in 10 patients, and the impact of the automated plan (AP) on the total treatment cost was estimated. For the remaining 46 patients, each plan was checked against our clinical objectives, and a pair-wise dose-volume histogram comparison was performed. Three experienced radiation oncologists evaluated each plan and indicated their preference. Results: APs reduced the average optimization time by 77.3% but only affected the total treatment cost by 3.6%. Three APs and 0 manual plans failed our clinical objectives, and 13 APs and 9 manual plans showed a minor deviation. APs significantly reduced D2% (2% of the volume receives a dose of at least D2%) for the spinal cord, esophagus, heart, aorta, and main stem bronchus (P <.05) while preserving target coverage. The radiation oncologists found > 75% of the APs clinically acceptable without any further fine-tuning. Conclusions: APs may help to create satisfactory treatment plans quickly and effectively. Because critical appraisal by qualified professionals remains necessary, there is no such thing as "fully automated" planning yet. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 50 条
  • [1] Automated instead of manual planning for lung SBRT? A plan comparison based on dose-volume statistics
    Vanderstraeten, B.
    Goddeeris, B.
    Derie, C.
    Vandecasteele, K.
    Van Eijkeren, M.
    Paelinck, L.
    De Wagter, C.
    Lievens, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S37 - S37
  • [2] DOSE-VOLUME HISTOGRAM BASED INVERSE OPTIMIZATION FOR CERVIX CANCER BRACHYTHERAPY PLANNING: IMPLEMENTATION OF CLINICAL EXPERIENCE FROM MANUAL TREATMENT PLANNING
    Trnkova, P.
    Baltas, D.
    Dimopoulos, J.
    Poetter, R.
    Kirlsits, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S40 - S41
  • [3] Global optimization of dose-volume based inverse treatment planning
    Gaede, S
    Wong, E
    Rasmussen, H
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1486 - 1487
  • [4] Comparison of rectal dose-volume constraints for IMRT prostate treatment planning
    Odrazka, K
    Zouhar, M
    Petera, J
    Vaculikova, M
    Dolezel, M
    Vosmik, M
    Tucek, P
    [J]. PHYSICA MEDICA, 2005, 21 (04) : 129 - 135
  • [5] Dose-volume constrained radiotherapy optimization for a clinical treatment planning system
    Gustafsson, A
    Langer, M
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 14 - 16
  • [6] Dose-Volume Histogram Analysis and Clinical Evaluation of Knowledge-Based Plan with Manual Objective Constraints for Pharyngeal Cancer
    Uehara, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E138 - E138
  • [7] Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH)
    Cheng, CW
    Das, IJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 1143 - 1150
  • [8] A comparison of automated and manual dose-volume data extraction for HDR prostate patients: implications for tolerance data
    Hanley, J
    Rebo, I
    Kapulsky, A
    Ndlovu, AM
    Napoli, JJ
    Gejerman, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S5 - S6
  • [9] DOSE-VOLUME DISTRIBUTIONS - A NEW APPROACH TO DOSE-VOLUME HISTOGRAMS IN 3-DIMENSIONAL TREATMENT PLANNING
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1994, 21 (01) : 3 - 11
  • [10] Dose-Volume Constraints for Particle Therapy Treatment Planning
    Stewart, R.
    Smith, W.
    Hendrickson, K.
    Meyer, J.
    Cao, N.
    Lee, E.
    Gopan, O.
    Sandison, G.
    Parvathaneni, U.
    Laramore, G.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3491 - 3491