Determination of Umbilical Venous Catheter Tip Position With Radiograph

被引:45
|
作者
Hoellering, Adam B. [1 ,2 ]
Koorts, Pieter J. [1 ,2 ]
Cartwright, David W. [1 ,2 ]
Davies, Mark W. [1 ,2 ]
机构
[1] Royal Brisbane & Womens Hosp, Grantley Stable Neonatal Unit, Brisbane, Qld, Australia
[2] Univ Queensland, Dept Paediat & Child Hlth, Brisbane, Qld, Australia
关键词
catheters; chest films; inferior; neonatal care; ultrasound; umbilical veins; vena cava; PERICARDIAL-EFFUSION; COMPLICATIONS; LOCALIZATION; ULTRASOUND; TAMPONADE; NEWBORN;
D O I
10.1097/PCC.0b013e31829f5efa
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To compare the cardiac silhouette method with the vertebral body method in predicting the umbilical venous catheter tip position on ultrasound; to measure the length of the target zone for the umbilical venous catheter tip; and to determine the time taken for a neonatologist to ascertain position of the umbilical venous catheter tip with ultrasound. Design: Prospective cohort study. Setting: Neonatal ICU. Patients: Newborn infants with an umbilical venous catheter. Interventions: Ultrasound scans to determine the umbilical venous catheter tip position were performed within an hour of corresponding anteroposterior chest-abdominal radiograph. Measurements and Main Results: Two hundred paired radiograph and ultrasound scans in 82 newborn infants were analyzed. Each radiograph was reviewed independently by an experienced neonatologist who recorded the position of the umbilical venous catheter tip by vertebral level and by the cardiac silhouette method. For each method, the sensitivity, specificity, and positive and negative predictive values were calculated for the prediction of the true position of the catheter tip on ultrasound. The umbilical venous catheter tip was well positioned in just 28 of 200 scans. The cardiac silhouette method was superior to the vertebral level method for all test variables, with a sensitivity and specificity of 86% and 94% compared with 61% and 74%. The length of the target zone approximates to a single T8 vertebral body height on radiograph. Conclusions: For radiograph and ultrasound scans performed within an hour of each other, the cardiac silhouette method more accurately predicts umbilical venous catheter tip than vertebral body level and methods described in previous studies. Catheters are frequently malpositioned. The length of the target zone for optimal umbilical venous catheter tip position is short. Ultrasound assessment of umbilical venous catheter tip position is quick.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 50 条
  • [41] Central venous catheter tip and perforation
    Caruso, LJ
    Gravenstein, N
    Layon, AJ
    Gabrielli, A
    ANESTHESIA AND ANALGESIA, 2003, 96 (01): : 301 - 302
  • [42] Migration of the Tip of a Central Venous Catheter
    Shariat, M.
    Zahiah, M.
    Chan, P. K.
    IRANIAN JOURNAL OF RADIOLOGY, 2008, 5 (04) : 239 - 243
  • [43] Evaluation of epidural catheter tip position
    René Martin
    Martine Pirlet
    Michel Parent
    France Gingras
    Canadian Journal of Anesthesia, 2003, 50
  • [44] Ultrasound-Guided Umbilical Venous Catheter Insertion to Reduce Rate of Catheter Tip Malposition in Neonates: A Randomized, Controlled Trial
    Amandeep Kaur
    Swati Manerkar
    Saikat Patra
    Pavan Kalamdani
    Thaslima Kalathingal
    Jayashree Mondkar
    Indian Journal of Pediatrics, 2022, 89 : 1093 - 1098
  • [45] Utilization of neural networks for catheter tip position determination in intraventricular impedance imaging
    Walker, GW
    Kun, S
    Peura, RA
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 796 - 797
  • [46] Ultrasound-Guided Umbilical Venous Catheter Insertion to Reduce Rate of Catheter Tip Malposition in Neonates: A Randomized, Controlled Trial
    Kaur, Amandeep
    Manerkar, Swati
    Patra, Saikat
    Kalamdani, Pavan
    Kalathingal, Thaslima
    Mondkar, Jayashree
    INDIAN JOURNAL OF PEDIATRICS, 2022, 89 (11): : 1093 - 1098
  • [47] Is Bedside Ultrasonography Rapid and Accurate for Confirmation of Central Venous Catheter Position and Exclusion of Pneumothorax Compared With Chest Radiograph?
    Long, Brit
    April, Michael D.
    ANNALS OF EMERGENCY MEDICINE, 2017, 70 (04) : 585 - 587
  • [48] Superiority of targeted neonatal echocardiography for umbilical venous catheter tip localization: accuracy of a clinician performance model
    A S Pulickal
    P K Charlagorla
    S C Tume
    M Chhabra
    P Narula
    A M Nadroo
    Journal of Perinatology, 2013, 33 : 950 - 953
  • [49] Superiority of targeted neonatal echocardiography for umbilical venous catheter tip localization: accuracy of a clinician performance model
    Pulickal, A. S.
    Charlagorla, P. K.
    Tume, S. C.
    Chhabra, M.
    Narula, P.
    Nadroo, A. M.
    JOURNAL OF PERINATOLOGY, 2013, 33 (12) : 950 - 953
  • [50] Interpretation of Umbilical Venous Catheter position on X-ray: a trainee's perspective.
    Harrison, Eleanor Katherine
    Lydekker, Kate
    Sellwood, Mark
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (11) : 1514 - 1514