Equivalent concrete layer thickness of a fire protection insulation layer

被引:8
|
作者
Wickstrom, U
Hadziselimovic, E
机构
[1] Swed. Natl. Test. and Res. Institute, Fire Technology, Box 857
关键词
D O I
10.1016/S0379-7112(96)00023-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The reinforcement bars in a concrete structure are usually protected against fire only by the concrete cover layer. In some cases an additional protection is needed and hence protective layers are applied, which consist of light-weight insulation materials. The theoretical analysis outlined in this paper shows that: (a) the thermal protection capacity of a protection layer can indeed be expressed as an equivalent concrete layer; and (b) a simple relation can be established between the thermal resistance (R=delta/k) of the protection layer and the thickness of an equivalent concrete protection. The equivalent concrete thickness yields the same time for reinforcement bars to reach 500 degrees C as the corresponding thermal protection layer when the structure is exposed to the standard ISO 834 fire. All the analyses have been carried out with the finite element temperature analysis computer program TASEF. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 50 条
  • [41] Evaluating the potential of using foamed concrete as the insulation layer for pavements in cold regions
    Zhuo, Zhuang
    Ali, Ayman
    Zhu, Cheng
    Mehta, Yusuf
    Lein, Wade
    DeCarlo, Christopher
    Elshaer, Mohamed
    Kennedy, Danielle
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 341
  • [42] Application of low drying shrinkage ECC in the protection layer of thermal insulation wall
    Chang, Jiang
    Hu, Jianjun
    Pei, Tianchen
    Zhu, Zhankui
    Zhao, Yongsheng
    Xie, Shixiang
    Xun, Jian
    Liu, Yuzhang
    Jun, Zhang
    JOURNAL OF SUSTAINABLE CEMENT-BASED MATERIALS, 2023, 12 (12) : 1495 - 1508
  • [44] A New Method to Fabricate Sidewall Insulation of TSV Using a Parylene Protection Layer
    Ji, Ming
    Zhu, Yunhui
    Ma, Shenglin
    Sun, Xin
    Miao, Min
    Jin, Yufeng
    2009 INTERNATIONAL CONFERENCE ON ELECTRONIC PACKAGING TECHNOLOGY & HIGH DENSITY PACKAGING (ICEPT-HDP 2009), 2009, : 1257 - +
  • [45] Fire-protection of wooden structures by modification in a thin surface layer
    Pokrovskaya, Elena
    VI INTERNATIONAL SCIENTIFIC CONFERENCE INTEGRATION, PARTNERSHIP AND INNOVATION IN CONSTRUCTION SCIENCE AND EDUCATION (IPICSE-2018), 2018, 251
  • [46] Heating and charring of timber constructions with thin-layer fire protection
    Polishchuk, E. Yu.
    Sivenkov, A. B.
    Kenzhehan, S. K.
    MAGAZINE OF CIVIL ENGINEERING, 2018, 81 (05): : 3 - 14
  • [47] Influence of Protective Layer Thickness on the Mechanical Properties of Reinforced Concrete Beam
    Li Wei-hong
    Ma Feng-hai
    TESTING AND EVALUATION OF INORGANIC MATERIALS I, 2011, 177 : 549 - 553
  • [48] Prediction of the yield stress of concrete considering the thickness of excess paste layer
    Lee, Jin Hyun
    Kim, Jae Hong
    Yoon, Jin Young
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 173 : 411 - 418
  • [49] Study on the quality of fragile surface layer of concrete by the thickness of member section
    Aba, M.
    Sakoi, Y.
    Tsukinaga, Y.
    Gondai, Y.
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 1189 - 1194
  • [50] Determination of Lubrication Layer Thickness and Its Effect on Concrete Pumping Pressure
    Deng, Rong
    Ye, Tong
    Ye, Zhiwei
    Materials, 2024, 17 (20)