Effects of common surfactants on protein digestion and matrix-assisted laser desorption/ionization mass spectrometric analysis of the digested peptides using two-layer sample preparation

被引:79
|
作者
Zhang, N [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1002/rcm.1423
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
While surfactants are commonly used in preparing protein samples, their presence in a protein sample can potentially affect the enzymatic digestion process and the subsequent analysis of the resulting peptides by mass spectrometry. The extent of the tolerance of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) to surfactant interference in peptide analysis is very much dependent on the matrix/sample preparation method. In this work the effects of four commonly used surfactants, namely n-octyl glucoside (OG), Triton X-100 (TX-100), 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS) and sodium dodecyl sulfate (SDS), for biological sample preparation on trypsin digestion and MALDI-MS of the resulting digest are examined in detail within the context of using a two-layer method for MALDI matrix/sample preparation. Non-ionic and mild surfactants, such as OG, TX-100 or CHAPS, are found to have no significant effect on trypsin digestion with surfactant concentrations up to 1%. However, TX-100 and CHAPS interfere with the subsequent peptide analysis by MALDI-MS and should be removed prior to peptide analysis. OG is an MS-friendly surfactant and no effect is observed for MALDI peptide analysis. The effect of SDS on trypsin digestion in terms of the number of peptides generated and the overall protein sequence coverage by these peptides is found to be protein dependent. The use of SDS to solubilize hydrophobic membrane proteins, followed by trypsin digestion in the presence of 0.1% SDS, results in a peptide mixture that can be analyzed directly by MALDIMS. These peptides are shown to provide better sequence coverage compared with those obtained without the use of SDS in the case of bacteriorhodopsin, a very hydrophobic transmembrane protein. This work illustrates that MALDI-MS with the two-layer sample preparation method can be used for direct analysis of protein digests with no or minimum sample cleanup after proteins are digested in a solution containing surfactants. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:889 / 896
页数:8
相关论文
共 50 条
  • [31] Electromembrane Extraction of Posaconazole for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Detection
    Chen, Chi-Sheng
    Chen, Wen-Chi
    Chang, Sarah Y.
    MEMBRANES, 2022, 12 (06)
  • [32] Matrix-assisted laser desorption/ionization mass spectrometry imaging sample preparation using wet-interface matrix deposition for lipid analysis
    Mielczarek, Przemyslaw
    Suder, Piotr
    Kret, Paulina
    Slowik, Tymoteusz
    Gibula-Tarlowska, Ewa
    Kotlinska, Jolanta Helena
    Kotsan, Igor
    Bodzon-Kulakowska, Anna
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (14)
  • [33] Oil-Assisted Sample Preparation: A Simple Method for Analysis of Solid Samples Using Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    So, Pui-Kin
    Yao, Zhong-Ping
    ANALYTICAL CHEMISTRY, 2011, 83 (13) : 5175 - 5181
  • [34] Analysis of protein sequences and protein complexes by matrix-assisted laser desorption/ionization mass spectrometry
    Belghazi, M
    Bathany, K
    Hountondji, C
    Grandier-Vazeille, X
    Manon, S
    Schmitter, JM
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2001, 7 (02) : 101 - 109
  • [35] Analysis of protein sequences and protein complexes by matrix-assisted laser desorption/ionization mass spectrometry
    Belghazi, M
    Bathany, K
    Hountondji, C
    Grandier-Vazeille, X
    Manon, S
    Schmitter, JM
    PROTEOMICS, 2001, 1 (08) : 946 - 954
  • [36] Matrix-assisted laser desorption ionization mass spectrometric analysis of aromatic polyether dendritic systems.
    Hayes, W
    Freeman, AW
    Frechet, JMJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 127 - PMSE
  • [37] Systematic assessment of surfactants for matrix-assisted laser desorption/ionization mass spectrometry imaging
    Banstola, Bijay
    Grodner, Eulalie T.
    Cao, Fan
    Donnarumma, Fabrizio
    Murray, Kermit K.
    ANALYTICA CHIMICA ACTA, 2017, 963 : 76 - 82
  • [38] Protein identification with Teflon as matrix-assisted laser desorption/ionization sample support
    Yuan, XL
    Desiderio, DM
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (05): : 512 - 524
  • [39] Effect of solvent on ionization efficiency in matrix-assisted laser desorption/ionization mass spectrometry of peptides
    Hazama, Hisanao
    Furukawa, Satoshi
    Awazu, Kunio
    CHEMICAL PHYSICS, 2013, 419 : 196 - 199
  • [40] Direct matrix-assisted laser desorption/ionization mass spectrometric analysis of glycosphingolipids on thin layer chromatographic plates and transfer membranes
    Guittard, J
    Hronowski, XPL
    Costello, CE
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (18) : 1838 - 1849