ACOUSTIC METHODS OF MICROPHONE CALIBRATION

被引:0
|
作者
Walber, Chad [1 ]
Salzano, Carmine [1 ]
Nowak, Mark [1 ]
Larratta, Nicholas [1 ]
机构
[1] PCB Piezotron Inc, Walden Ave 3425, Depew, NY 14043 USA
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Microphone sensitivity is used by engineers as an indication of microphone health. Tracking sensitivity over time is typically the best indication of microphone stability. Unfortunately, engineers typically rely on the microphone frequency response calibration given by an outside lab as the sole source for correction in any acoustic measurements they make. It may be necessary, however, to be able to verify the frequency response in order to increase the overall accuracy of your measurements. Condenser microphones are typically calibrated via an electrostatic actuator by the manufacturer, and then a correction factor for the appropriate field is applied to the microphone calibration. The correction factors for those calibrations are well known. Array microphones cannot be calibrated via electrostatic methods, due to the lack of a metal diaphragm, and must be calibrated using acoustic methods. This discussion will outline acoustic methods of microphone calibration which are appropriate for both condenser microphones and array microphones. The measurements of pressure and free field response will be described as per IEC standards.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] 2-MICROPHONE MEASUREMENT OF ACOUSTIC INTENSITY IN THE EAR CANAL AS A CALIBRATION OF HIGH-FREQUENCY HEARING
    MURPHY, WJ
    TUBIS, A
    LONG, GR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1987, 81 : S75 - S75
  • [32] MICROPHONE CALIBRATION BY MEANS OF A SUPERSONIC JET
    BORISOV, YY
    MAMIN, VM
    SOVIET PHYSICS ACOUSTICS-USSR, 1971, 17 (01): : 123 - &
  • [33] Pressure reciprocity calibration of a MEMS microphone
    Wagner, Randall P.
    Fick, Steven E.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2017, 142 (03): : EL251 - EL257
  • [34] CALIBRATION OF A CONDENSER MICROPHONE MICROMETEOROID SENSOR
    EVANS, RL
    GLASS, II
    CANADIAN AERONAUTICS AND SPACE JOURNAL, 1970, 16 (09): : 375 - &
  • [35] Imaging of heart acoustic based on the sub-space methods using a microphone array
    Moghaddasi, Hanie
    Almasganj, Farshad
    Zoroufian, Arezoo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 146 : 133 - 142
  • [36] Traceability of acoustic emission measurements using energy calibration methods
    Yan, T
    Jones, BE
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (11) : L9 - L12
  • [37] A Comparison of Two Methods for Absolute Calibration of Acoustic Emission Sensors
    Panteleev, I.
    Saveleva, N.
    Prokhorov, A.
    Vshivkov, A.
    MECHANICS, RESOURCE AND DIAGNOSTICS OF MATERIALS AND STRUCTURES (MRDMS-2018), 2018, 2053
  • [38] Review of the Calibration for Partial Discharge Detectors by Electromagnetic and Acoustic Methods
    Wang, Yifan
    Sun, Ming
    Wang, Zun
    Zou, Chengwu
    Gong, Jinlong
    Jiang, Jiongting
    2022 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (I&CPS ASIA 2022), 2022, : 406 - 410
  • [39] CROSS-SPECTRAL METHOD OF MEASURING ACOUSTIC INTENSITY BY CORRECTING PHASE AND GAIN MISMATCH ERRORS BY MICROPHONE CALIBRATION
    KRISHNAPPA, G
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1981, 69 (01): : 307 - 310
  • [40] A study on calibration frequency limit of acoustic chamber type microphone calibrator and improvement method using mode shape
    Kim, Chayeong
    Shin, Kumjae
    Moon, Wonkyu
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2022, 41 (01): : 1 - 8