Design and Reliability of a Novel Heel Rise Test Measuring Device for Plantarflexion Endurance

被引:30
|
作者
Sman, Amy D. [1 ]
Hiller, Claire E. [1 ]
Imer, Adam [1 ]
Ocsing, Aldrin [1 ]
Burns, Joshua [1 ,2 ]
Refshauge, Kathryn M. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Discipline Physiotherapy, Lidcombe, NSW 1825, Australia
[2] Childrens Hosp Westmead, Inst Neurosci & Muscle Res, Westmead, NSW 2145, Australia
关键词
FLEXION; INJURY;
D O I
10.1155/2014/391646
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Plantarflexion results from the combined action of the soleus and gastrocnemius muscles in the calf. The heel rise test is commonly used to test calf muscle endurance, function, and performance by a wide variety of professionals; however, no uniform description of the test is available. This paper aims to document the construction and reliability of a novel heel rise test device and measurement protocol that is suitable for the needs of most individuals. Methods. This device was constructed from compact and lightweight materials and is fully adjustable, enabling the testing of a wide variety of individuals. It is easy to assemble and disassemble, ensuring that it is portable for use in different settings. Findings. We tested reliability on 40 participants, finding excellent interrater reliability (ICC2,1 0.97, 95% CI: 0.94 to 0.98). Limits of agreement were less than two repetitions in 90% of cases and the Bland-Altman plot showed no bias. Interpretation. We have designed a novel, standardized, simple, and reliable device and measurement protocol for the heel rise test which can be used by researchers and clinicians in a variety of settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A Novel Roller Chain Sleeve Crevice Identification and Orientation Device Design and Test
    Ding, Song
    Liu, Xiaolun
    Zhang, Yingbo
    Liu, Jiajun
    Zhu, Guoyu
    Wang, Pan
    ADVANCED DESIGNS AND RESEARCHES FOR MANUFACTURING, PTS 1-3, 2013, 605-607 : 175 - +
  • [42] Design for enhanced solder joint reliability of integrated passives device under board level drop test and thermal cycling test
    Tee, TY
    Ng, HS
    Zhong, ZW
    PROCEEDINGS OF 5TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2003, : 210 - 216
  • [43] Test-retest reliability of gaze precision of a novel virtual reality-based medical device
    Coito, Ana
    Naidu, Avantika
    Lehmann, Julian
    Hauser, Bruno
    Brugger, Dominik
    Abegg, Mathias
    FRONTIERS IN VIRTUAL REALITY, 2025, 6
  • [44] P-Cone: A Novel Cone Penetration Test Device for Deep Foundation Design
    Nguyen, H. M.
    Puppala, A. J.
    GEOTECHNICAL ENGINEERING, 2020, 51 (02): : 47 - 53
  • [45] Design and analysis of the novel test tube magnet as a device for portable nuclear magnetic resonance
    Chen, Jizhong
    Xu, Chunyan
    IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (09) : 3555 - 3557
  • [46] Validity and Test-Retest Reliability of a Hand-Held Ultrasound Device in Measuring Kidney Metrics in Healthy Young Adults
    Miller, Kevin E.
    Walters, Josee
    Bautista, Jimmy
    Smith, Bailee R.
    Robinson, Timothy J.
    Schmitt, Emily E.
    Bruns, Danielle R.
    Schlader, Zachary J.
    Johnson, Evan C.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2024,
  • [47] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Luedtke, Kerstin
    Schoettker-Koeniger, Thomas
    Hall, Toby
    Enns, Christine
    Grassold, Maike
    Hasselhoff-Styhler, Petra
    Neulinger, Christian
    Obrocki, Max
    Przyhoda, Philipp
    Schaefer, Axel
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [48] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Kerstin Luedtke
    Thomas Schoettker-Königer
    Toby Hall
    Christine Reimer
    Maike Grassold
    Petra Hasselhoff-Styhler
    Christian Neulinger
    Max Obrocki
    Philipp Przyhoda
    Axel Schäfer
    BMC Musculoskeletal Disorders, 21
  • [49] Design and Research of Online Measuring Device of Dielectric Loss Angle in Insulation Test Based on STM32
    He, Weitian
    Jiang, Cunbo
    Zhu, Tiantian
    2018 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2019, 252
  • [50] STRUCTURE DESIGN AND PERFORMANCE TEST OF A HIGH TEMPERATURE RISE COMBUSTOR BASED ON COMBUSTION-GAS WIND TUNNEL DEVICE
    Lou, Fengfei
    Dong, Sujun
    Zhao, Banghua
    Qi, Bin
    HEAT TRANSFER RESEARCH, 2022, 53 (13) : 21 - 36