Design and Reliability of a Novel Heel Rise Test Measuring Device for Plantarflexion Endurance

被引:30
|
作者
Sman, Amy D. [1 ]
Hiller, Claire E. [1 ]
Imer, Adam [1 ]
Ocsing, Aldrin [1 ]
Burns, Joshua [1 ,2 ]
Refshauge, Kathryn M. [1 ]
机构
[1] Univ Sydney, Fac Hlth Sci, Discipline Physiotherapy, Lidcombe, NSW 1825, Australia
[2] Childrens Hosp Westmead, Inst Neurosci & Muscle Res, Westmead, NSW 2145, Australia
关键词
FLEXION; INJURY;
D O I
10.1155/2014/391646
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Plantarflexion results from the combined action of the soleus and gastrocnemius muscles in the calf. The heel rise test is commonly used to test calf muscle endurance, function, and performance by a wide variety of professionals; however, no uniform description of the test is available. This paper aims to document the construction and reliability of a novel heel rise test device and measurement protocol that is suitable for the needs of most individuals. Methods. This device was constructed from compact and lightweight materials and is fully adjustable, enabling the testing of a wide variety of individuals. It is easy to assemble and disassemble, ensuring that it is portable for use in different settings. Findings. We tested reliability on 40 participants, finding excellent interrater reliability (ICC2,1 0.97, 95% CI: 0.94 to 0.98). Limits of agreement were less than two repetitions in 90% of cases and the Bland-Altman plot showed no bias. Interpretation. We have designed a novel, standardized, simple, and reliable device and measurement protocol for the heel rise test which can be used by researchers and clinicians in a variety of settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION
    Ness, Brandon M.
    Sudhagoni, Ramu G.
    Tao, Hanz
    Full, Olivia R.
    Seehafer, Lucas O.
    Walder, Chelsie M.
    Zimney, Kory
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2018, 13 (01): : 19 - 27
  • [2] Reliability and Validity of the Standing Heel-Rise Test
    Yocum, Allison
    McCoy, Sarah Westcott
    Bjornson, Kristie F.
    Mullens, Pamela
    Burton, Gay Naganuma
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2010, 30 (03) : 190 - 204
  • [3] Test-retest reliability of the standing heel-rise test
    Ross, MD
    Fontenot, EG
    JOURNAL OF SPORT REHABILITATION, 2000, 9 (02) : 117 - 123
  • [4] Reliability and Validity of the Heel Rise Test Using the Mobile Application
    Song, Jun-Young
    Park, Sam-Ho
    Kim, Byeong-Soo
    Lee, Myung-Mo
    ANNALS OF APPLIED SPORT SCIENCE, 2023, 11 (03):
  • [5] Intrarater reliability and agreement of linear encoder derived heel-rise endurance test outcome measures in healthy adults
    Byrne, Christopher
    Keene, David J.
    Lamb, Sarah E.
    Willett, Keith
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2017, 36 : 34 - 39
  • [6] The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance
    Möller, M
    Lind, K
    Styf, J
    Karlsson, J
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (01) : 60 - 71
  • [7] The reliability of isokinetic testing of the ankle joint and a heel-raise test for endurance
    Michael Möller
    Karin Lind
    Jorma Styf
    Jon Karlsson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 60 - 71
  • [8] Updated reliability and normative values for the standing heel-rise test in healthy adults
    Hebert-Losier, K.
    Wessman, C.
    Alricsson, M.
    Svantesson, U.
    PHYSIOTHERAPY, 2017, 103 (04) : 446 - 452
  • [9] Test-Retest Reliability of a Pendant-Worn Sensor Device in Measuring Chair Rise Performance in Older Persons
    Zhang, Wei
    Regterschot, G. Ruben H.
    Schaabova, Hana
    Baldus, Heribert
    Zijlstra, Wiebren
    SENSORS, 2014, 14 (05): : 8705 - 8717
  • [10] Design of a Novel Device for Measuring the Inertia of Helmet
    Chen, Xiao
    Zhang, Cong
    Zhang, Wei
    Ma, Chuang
    Niu, Jianwei
    PROCEEDINGS OF THE 15TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2020), 2020, : 54 - 58