Electrospun nanofibrous membranes coated quartz crystal microbalance as gas sensor for NH3 detection

被引:219
|
作者
Ding, B
Kim, JH
Miyazaki, Y
Shiratori, SM [1 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Yokohama, Kanagawa 2238522, Japan
[2] Shiratori Nanotechnol Co Ltd, Kawasaki, Kanagawa 2120054, Japan
关键词
nanofibrous membranes; electrospinning; quartz crystal microbalance (QCM); gas sensor; resonance frequency shift;
D O I
10.1016/j.snb.2004.04.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel gas sensor composed of electrospun nanofibrous membranes and quartz crystal microbalance (QCM) was successfully fabricated. The electrospun nanofibers with diameter of 100-400 nm can be deposited on the surface of QCM by clectrospinning the homogenous blend solutions of cross-linkable poly(acrylic acid) (PAA) and poly(vinyl alcohol) (PVA). A series of nanofibrous membranes with various weight percentage of PAA to PVA were fabricated and characterized regarding their morphology and sensitivity to NH3. Sensing experiments were examined by measuring the resonance frequency shifts of QCM which due to the additional mass loading. The results showed that the sensing properties were mainly affected by the content of PAA component in nanofibrous membranes, concentration of NH3, and relative humidity. Additionally, the sensitivity of nanotibrous membranes coated (NMC) QCM sensor was much higher than that of continuous films coated QCM sensor. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:373 / 380
页数:8
相关论文
共 50 条
  • [41] Detection of β-caryophyllene in mango using a quartz crystal microbalance sensor
    Ali, Sk Babar
    Ghatak, Barnali
    Debabhuti, Nilava
    Sharma, Prolay
    Ghosh, Arunangshu
    Tudu, Bipan
    Bhattacharya, Nabarun
    Bandyopadhyay, Rajib
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 3064 - 3073
  • [42] Quartz crystal microbalance sensor for detection of aliphatic amines vapours
    Ayad, Mohamad M.
    Torad, Nagy L.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (02) : 481 - 487
  • [43] Aliphatic amines vapours detection by quartz crystal microbalance sensor
    Das, Rashmita
    Pradhan, Susmita
    Biswas, Sudip
    Sharma, Prolay
    Ghosh, Arunangshu
    Bandyopadhyay, Rajib
    Pramanik, Panchanan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 94 - 101
  • [44] A quartz crystal microbalance sensor for the detection of formic acid vapors
    C. García-Verdugo-Caso
    J. L. Hidalgo-Hidalgo-de-Cisneros
    I. Naranjo-Rodríguez
    D. Bellido-Milla
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 393 - 398
  • [45] QUARTZ CRYSTAL MICROBALANCE: NANO-SENSOR FOR CYANIDE DETECTION
    Dulama, Ioana Daniela
    Popescu, Ion V.
    Cimpoca, Gheorghe Valerica
    Radulescu, Cristiana
    Bucurica, Ioan Alin
    Bancuta, Iulian
    JOURNAL OF SCIENCE AND ARTS, 2012, (02): : 201 - 206
  • [46] A quartz crystal microbalance sensor for the detection of formic acid vapors
    García-Verdugo-Caso, C
    Hidalgo-Hidalgo-de-Cisneros, JL
    Naranjo-Rodríguez, I
    Bellido-Milla, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (04): : 393 - 398
  • [47] A quartz crystal microbalance (QCM) sensor for the detection of Bacillus cereus
    Vaughan, RD
    Carter, RM
    O'Sullivan, CK
    Guilbault, GG
    ANALYTICAL LETTERS, 2003, 36 (04) : 731 - 747
  • [48] A Quartz Crystal Microbalance Sensor for Detection of Geraniol in Black Tea
    Sharma, Prolay
    Ghosh, Arunangshu
    Tudu, Bipan
    Bhuyan, Lakshi Prasad
    Tamuly, Pradip
    Bhattacharyya, Nabarun
    Bandyopadhyay, Rajib
    Das, Udhab
    IEEE SENSORS JOURNAL, 2015, 15 (02) : 1178 - 1185
  • [49] Detection of globular and fibrillar proteins by quartz crystal microbalance sensor coated with a functionalized diamond thin film
    Prochazka, V
    Kulha, P.
    Izsak, T.
    Ukraintsev, E.
    Varga, M.
    Jirasek, V
    Kromka, A.
    APPLIED SURFACE SCIENCE, 2022, 589
  • [50] Detection of Volatile Organic Compounds by Analyses of Polymer-Coated Quartz Crystal Microbalance Sensor Arrays
    Kimura, Mutsumi
    Liu, Ye
    Sakai, Ryosuke
    Sato, Seiko
    Hirai, Toshihiro
    Fukawa, Tadashi
    Mihara, Takashi
    SENSORS AND MATERIALS, 2011, 23 (07) : 359 - 368