Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles

被引:22
|
作者
Dunning, Chelsea A. S. [1 ]
Bazalova-Carter, Magdalena [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
computed tomography; collimators; gold nanoparticles; molecular imaging; x-ray fluorescence; SENSITIVITY; XFET;
D O I
10.1002/mp.12893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. The feasibility of a multipinhole, parallel, and converging collimator was investigated in a Monte Carlo study. Methods: A cylindrical water phantom with 2 cm in diameter and 3 cm in height containing 0.52 mm diameter vials with 0.4%-1.6% AuNP concentrations was modelled by FLUKA. A 15 and 81 keV monoenergetic x-ray sheet beam of 0.4 mm in width was used to image the phantom with L-shell and K-shell XFCT, respectively, with a dose of 30 mGy. The collimator thickness for L-shell and K-shell data acquisition was 3.3 and 5.1 mm, respectively. The XFCT images resulting from three collimator geometries were generated using the maximum likelihood expectation maximization (MLEM) iterative reconstruction method. With a resolution of 0.4 mm they were corrected for x-ray attenuation. The sheet beam XFCT images were compared against pencil beam geometry images that were generated using 55 translations. To assess image quality, the contrast-to-noise ratio (CNR) was evaluated for each vial. The Rose criterion was used to determine the lowest AuNP concentration detectable for each image. Results: Among the three collimator geometry types, the sheet beam L-shell and K-shell parallel collimator XFCT images yielded AuNP sensitivity limits at 0.09% and 0.08%, respectively, for a 2 mm diameter vial. The AuNP sensitivity limits of the pencil beam XFCT images were 0.07% and 0.01% for L-shell and K-shell XFCT, respectively. The L-shell parallel collimator AuNP imaging sensitivity approached that of the pencil beam geometry with a 55-fold reduction in imaging time. The AuNP sensitivity limits for the 1 mm diameter vial for the L-shell and K-shell parallel collimator XFCT images were 0.19% and 0.16%, respectively, and those of the pencil beam XFCT images were 0.08% and 0.01% for L-shell and K-shell XFCT, respectively. The remaining two collimator geometries resulted in a lower CNR and poorer image quality. For a 2 mm diameter vial, the AuNP sensitivity limits for the L-shell and K-shell multipinhole collimator XFCT images were 0.23% and 0.52%, respectively, while for the L-shell and K-shell converging collimator XFCT images the AuNP sensitivity limits were 0.38% and 0.13%, respectively. Conclusion: This work demonstrates the feasibility of sheet beam L-shell XFCT imaging for small animal studies using parallel-oriented lead collimators which can detect AuNP concentrations approaching the level of pencil beam images with reduced imaging time. (c) 2018 American Association of Physicists in Medicine
引用
收藏
页码:2572 / 2582
页数:11
相关论文
共 50 条
  • [21] Optimized Detector Angular Configuration Increases the Sensitivity of X-ray Fluorescence Computed Tomography (XFCT)
    Ahmad, Moiz
    Bazalova-Carter, Magdalena
    Fahrig, Rebecca
    Xing, Lei
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (05) : 1140 - 1147
  • [22] Inorganic Nanoparticles for X-Ray Computed Tomography Imaging
    Attia, Mohamed F.
    Wallyn, Justine
    Anton, Nicolas
    Vandamme, Thierry F.
    [J]. CRITICAL REVIEWS IN THERAPEUTIC DRUG CARRIER SYSTEMS, 2018, 35 (05): : 391 - 431
  • [23] Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability
    Manohar, Nivedh
    Reynoso, Francisco J.
    Cho, Sang Hyun
    [J]. MEDICAL PHYSICS, 2018, 45 (10) : 4652 - 4659
  • [24] Optimization of Incident X-Ray Source Spectrum Through Filtration for a Benchtop X-Ray Fluorescence Computed Tomography (XFCT) System
    Manohar, N.
    Jones, B.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [25] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [26] Stabilizing gold nanoparticles for use in X-ray computed tomography imaging of soil systems
    Scotson, Callum P.
    Munoz-Hernando, Maria
    Duncan, Simon J.
    Ruiz, Siul A.
    Keyes, Samuel D.
    van Veelen, Arjen
    Dunlop, Iain E.
    Roose, Tiina
    [J]. ROYAL SOCIETY OPEN SCIENCE, 2019, 6 (10):
  • [27] Investigation of X-Ray Detection Configurations for X-Ray Fluorescence Computed Tomography (XFCT) Imaging of Gold Nanoparticle-Loaded Small Animal-Sized Phantoms: A Monte Carlo Study
    Ahmed, M. F.
    Deng, L.
    Jayarathna, S.
    Cho, S. H.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E172 - E172
  • [28] X-ray fluorescence computed tomography system for biomedical imaging
    Enomoto, Toshiyuki
    Sato, Eiichi
    Abderyim, Purkhet
    Matsukiyo, Hiroshi
    Osawa, Akihiro
    Watanabe, Manabu
    Nagao, Jiro
    Nomiya, Seiichiro
    Hitomi, Keitro
    Izumisawa, Mitsuru
    Ogawa, Akira
    Sato, Shigehiro
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS IX, 2008, 7080
  • [29] Experimental Demonstration of Cone-Beam Polychromatic X-Ray Fluorescence Computed Tomography (XFCT) Imaging of Gold Nanoparticle-Loaded Regions within Small Animal-Sized Phantoms
    Jones, B.
    Manohar, N.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [30] Drastic Performance Improvement of a Polychromatic Cone-Beam X-Ray Fluorescence Computed Tomography (XFCT) System Using a Kilowatt-Range X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3716 - 3716