Sheet beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticles

被引:22
|
作者
Dunning, Chelsea A. S. [1 ]
Bazalova-Carter, Magdalena [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8P 5C2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
computed tomography; collimators; gold nanoparticles; molecular imaging; x-ray fluorescence; SENSITIVITY; XFET;
D O I
10.1002/mp.12893
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray fluorescence computed tomography (XFCT) experiments have typically used pencil beams for data acquisition, which yielded good quality images of gold nanoparticles (AuNP) but prolonged the imaging time. Here we propose three novel collimator geometries for use with faster sheet beam XFCT data acquisition. The feasibility of a multipinhole, parallel, and converging collimator was investigated in a Monte Carlo study. Methods: A cylindrical water phantom with 2 cm in diameter and 3 cm in height containing 0.52 mm diameter vials with 0.4%-1.6% AuNP concentrations was modelled by FLUKA. A 15 and 81 keV monoenergetic x-ray sheet beam of 0.4 mm in width was used to image the phantom with L-shell and K-shell XFCT, respectively, with a dose of 30 mGy. The collimator thickness for L-shell and K-shell data acquisition was 3.3 and 5.1 mm, respectively. The XFCT images resulting from three collimator geometries were generated using the maximum likelihood expectation maximization (MLEM) iterative reconstruction method. With a resolution of 0.4 mm they were corrected for x-ray attenuation. The sheet beam XFCT images were compared against pencil beam geometry images that were generated using 55 translations. To assess image quality, the contrast-to-noise ratio (CNR) was evaluated for each vial. The Rose criterion was used to determine the lowest AuNP concentration detectable for each image. Results: Among the three collimator geometry types, the sheet beam L-shell and K-shell parallel collimator XFCT images yielded AuNP sensitivity limits at 0.09% and 0.08%, respectively, for a 2 mm diameter vial. The AuNP sensitivity limits of the pencil beam XFCT images were 0.07% and 0.01% for L-shell and K-shell XFCT, respectively. The L-shell parallel collimator AuNP imaging sensitivity approached that of the pencil beam geometry with a 55-fold reduction in imaging time. The AuNP sensitivity limits for the 1 mm diameter vial for the L-shell and K-shell parallel collimator XFCT images were 0.19% and 0.16%, respectively, and those of the pencil beam XFCT images were 0.08% and 0.01% for L-shell and K-shell XFCT, respectively. The remaining two collimator geometries resulted in a lower CNR and poorer image quality. For a 2 mm diameter vial, the AuNP sensitivity limits for the L-shell and K-shell multipinhole collimator XFCT images were 0.23% and 0.52%, respectively, while for the L-shell and K-shell converging collimator XFCT images the AuNP sensitivity limits were 0.38% and 0.13%, respectively. Conclusion: This work demonstrates the feasibility of sheet beam L-shell XFCT imaging for small animal studies using parallel-oriented lead collimators which can detect AuNP concentrations approaching the level of pencil beam images with reduced imaging time. (c) 2018 American Association of Physicists in Medicine
引用
收藏
页码:2572 / 2582
页数:11
相关论文
共 50 条
  • [1] Fan-beam X-ray Fluorescence Computed Tomography (XFCT) with Gold Nanoparticles
    Fang, Wei
    Li, Liang
    Zhang, Siyuan
    [J]. 2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [2] Alternative Geometries for X-Ray Fluorescence Computed Tomography (XFCT) Imaging of Gold Nanoparticles
    Dunning, C.
    Bazalova-Carter, M.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3289 - 3290
  • [3] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    [J]. MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [4] X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    [J]. PHOTONICS, 2021, 8 (07)
  • [5] First Demonstration of Multiplexed X-Ray Fluorescence Computed Tomography (XFCT) Imaging
    Kuang, Yu
    Pratx, Guillem
    Bazalova, Magdalena
    Meng, Bowen
    Qian, Jianguo
    Xing, Lei
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 262 - 267
  • [6] Alternative geometries for x-ray fluorescence CT (XFCT) imaging of gold nanoparticles
    Dunning, Chelsea
    Bazalova-Carter, Magdalena
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4369 - 4369
  • [7] Feasibility of X-ray Fluorescence Computed Tomography (XFCT) Imaging of Human Lung Tumors loaded with Gold Nanoparticles: A Monte Carlo Study
    Ahmed, Md Foiez
    Jayarathna, Sandun
    Cho, Sang Hyun
    [J]. 2018 IEEE 12TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (IEEE - NANOMED), 2018, : 250 - 254
  • [8] X-ray Fluorescence Computed Tomography (XFCT) for High-Sensitivity Imaging of Cisplatin
    Bazalova, M.
    Pratx, G.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S646 - S646
  • [9] Investigation of X-ray Fluorescence Computed Tomography (XFCT) and K-Edge Imaging
    Bazalova, Magdalena
    Kuang, Yu
    Pratx, Guillem
    Xing, Lei
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) : 1620 - 1627
  • [10] L-shell x-ray fluorescence computed tomography (XFCT) imaging of Cisplatin
    Bazalova, Magdalena
    Ahmad, Moiz
    Pratx, Guillem
    Xing, Lei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01): : 219 - 232