Biomechanical Effect of Different Graft Heights on Adjacent Segment and Graft Segment Following C4/C5 Anterior Cervical Discectomy and Fusion: A Finite Element Analysis

被引:10
|
作者
Zhang, Yuhua [1 ,2 ,3 ]
Zhou, Jiaming [1 ]
Guo, Xing [1 ]
Cai, Zongxi [2 ]
Liu, Haofei [2 ]
Xue, Yuan [1 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Dept Orthoped Surg, Tianjin, Peoples R China
[2] Tianjin Univ, Dept Mech, Tianjin, Peoples R China
[3] China Railway Design Corp, Underground Struct, Tianjin, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
基金
中国国家自然科学基金;
关键词
Biomechanical Phenomena; Finite Element Analysis; Intervertebral Disc; Spinal Fusion; SPINE; DISC; DEGENERATION; REMOVAL; MOTION;
D O I
10.12659/MSM.916629
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The finite element analysis (FEA) was used to explore the effect of different graft heights on adjacent segment and graft segment stress after C4/5 anterior cervical discectomy and fusion (ACDF). Material/Methods: A detailed, geometrically accurate 3-dimensional cervical spine model was successfully built from computed tomography (CT) scanning of a healthy adult male. We changed the graft height in C4-C5 to be 90%, 150%, 175%, and 200% of the preoperative disc height and simulated the postoperative scenarios with different bone graft height, respectively. A stress analysis was conducted on the adjacent segment and graft segment. Results: The maximum von Mises stress on C3-C4 showed that when the graft height was 200%, the values were 0.99 MPa, 0.85 MPa, 0.91 MPa, and 0.89 MPa in different loading conditions. For C5-C6, the maximum von Mises stress was 0.77 MPa, 0.83 MPa, 0.91 MPa, and 0.81 MPa, observed when the graft height was 175%, except in extension condition. With regard to graft segment (C4-C5), the biggest von Mises stress was 1.25 MPa, 1.77 MPa, 1.75 MPa, and 1.81 MPa observed at 200% graft height. For these 3 segments, the smallest von Mises stress was found at 150% graft height under the 4 loading conditions. Conclusions: The graft height makes an important difference on the stress on the adjacent segment and the graft segment after anterior cervical discectomy and fusion. A 150% graft height was considered the proper graft height in C4/C5 ACDF, with the lowest stress on the adjacent segment and the graft segment.
引用
收藏
页码:4169 / 4175
页数:7
相关论文
共 40 条
  • [21] Transient ischaemic attack (TIA) of spinal cord following anterior cervical discectomy and fusion (ACDF) at C5/6 with left sided graft from iliac crest: case report.
    Haque, M.
    Zobina, I.
    Antiga, S.
    Kumar, N.
    CEREBROVASCULAR DISEASES, 2015, 39 : 245 - 245
  • [22] How to reconstruct the lordosis of cervical spine in patients with Hirayama disease? A finite element analysis of biomechanical changes focusing on adjacent segments after anterior cervical discectomy and fusion
    Xiao Lu
    Fei Zou
    Feizhou Lu
    Xiaosheng Ma
    Xinlei Xia
    Jianyuan Jiang
    Journal of Orthopaedic Surgery and Research, 17
  • [23] How to reconstruct the lordosis of cervical spine in patients with Hirayama disease? A finite element analysis of biomechanical changes focusing on adjacent segments after anterior cervical discectomy and fusion
    Lu, Xiao
    Zou, Fei
    Lu, Feizhou
    Ma, Xiaosheng
    Xia, Xinlei
    Jiang, Jianyuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [24] Biomechanical Evaluation of a Novel S-Type, Dynamic Zero-Profile Cage Design for Anterior Cervical Discectomy and Fusion with Variations in Bone Graft Shape: A Finite Element Analysis
    Manickam, Pechimuthu Susai
    Roy, Sandipan
    Shetty, Gautam M.
    WORLD NEUROSURGERY, 2021, 154 : E199 - E214
  • [25] Biomechanical Analysis of the Three-Dimensional Motion Pattern of the Canine Cervical Spine Segment C4-C5
    Hofstetter, Martin
    Gedet, Philippe
    Doherr, Marcus
    Ferguson, Stephen J.
    Forterre, Franck
    VETERINARY SURGERY, 2009, 38 (01) : 49 - 58
  • [26] Biomechanical Comparison of Different Surgical Approaches for the Treatment of Adjacent Segment Diseases after Primary Transforaminal Lumbar Interbody Fusion: A Finite Element Analysis
    Ke, Wencan
    Zhang, Teng
    Wang, Bingjin
    Hua, Wenbin
    Wang, Kun
    Cheung, Jason Pui Yin
    Yang, Cao
    ORTHOPAEDIC SURGERY, 2023, 15 (10) : 2701 - 2708
  • [27] Biomechanical Comparison of Optimal Shapes for the Cervical Intervertebral Fusion Cage for C5-C6 Cervical Fusion Using the Anterior Cervical Plate and Cage (ACPC) Fixation System: A Finite Element Analysis
    Wang, Jiajia
    Qian, Zhihui
    Ren, Luquan
    MEDICAL SCIENCE MONITOR, 2019, 25 : 8379 - 8388
  • [28] Biomechanical effect of endplate defects on the intermediate vertebral bone in consecutive two-level anterior cervical discectomy and fusion: a finite element analysis
    Jiarui Zhang
    Wenzhao Chen
    Rui Weng
    De Liang
    Xiaobing Jiang
    Hongheng Lin
    BMC Musculoskeletal Disorders, 24
  • [29] Biomechanical effect of endplate defects on the intermediate vertebral bone in consecutive two-level anterior cervical discectomy and fusion: a finite element analysis
    Zhang, Jiarui
    Chen, Wenzhao
    Weng, Rui
    Liang, De
    Jiang, Xiaobing
    Lin, Hongheng
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [30] Biomechanical study of the stability of posterior cervical expansive open-door laminoplasty combined with bilateral C4/5 foraminotomy and short-segment lateral mass screw fixation: a finite element analysis
    Li, Kunpeng
    Yu, Qun
    Wang, Chongyi
    Zhang, Runtong
    Fu, Qingyang
    Feng, Yunze
    Liu, Chen
    Wang, Xinlong
    Zhang, Ronghan
    Li, Le
    Si, Haipeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):