Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study

被引:3
|
作者
Park, Jieun [1 ]
Kim, Junghun [1 ]
Chang, Yongmin [2 ]
Youn, Sung Won [3 ]
Lee, Hui Joong [2 ]
Kang, Eun-Ju [4 ]
Lee, Ki-Nam [4 ]
Suchanek, Vojtech [2 ]
Hyun, Sinjae [5 ]
Lee, Jongmin [2 ]
机构
[1] Kyungpook Natl Univ, Dept Biomed Engn, Daegu, South Korea
[2] Kyungpook Natl Univ & Hosp, Dept Radiol, 50,Sam Duk 2 Ga, Daegu 700721, South Korea
[3] Catholic Univ Daegu, Dept Radiol, Med Ctr, Daegu, South Korea
[4] Dong A Univ, Dept Radiol, Coll Med, Busan, South Korea
[5] Mercer Univ, Dept Biomed Engn, Macon, GA 31207 USA
基金
新加坡国家研究基金会;
关键词
Pulsatile flow; time-velocity curve; flow analysis; phase-contrast magnetic resonance imaging; doppler ultrasonography; WALL SHEAR-STRESS; TRANSCRANIAL DOPPLER ULTRASOUND; COMMON CAROTID-ARTERY; CEREBRAL-BLOOD-FLOW; IN-VIVO; MR-ANGIOGRAPHY; VOLUME FLOW; QUANTIFICATION; VALIDATION; PATTERNS;
D O I
10.1080/24699322.2019.1649066
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this study was to analyze the characteristics of time-velocity curve acquired by phase-contrast magnetic resonance imaging (PC-MRI) using an in-vitro flow model as a reference for hemodynamic studies. The time- velocity curves of the PC-MRI were compared with Doppler ultrasonography (US) and also compared with those obtained in the electromagnetic flowmeter. The correlation between techniques was analyzed using an electromagnetic flowmeter as a reference standard; the maximum, minimum, and average velocities, full-width at half-maximum (FWHM), and ascending gradient (AG) were measured from time-velocity curves. The correlations between an electromagnetic flowmeter and the respective measurement technique for the PC-MRI and Doppler US were found to be high (mean R-2 > 0.9, p < 0.05). These results indicate that these measurement techniques are useful for measuring blood flow information and reflect actual flow. The PC-MRI was the best fit for the minimum velocity and FWHM, and the maximum velocity and AG were the best fit for Doppler US. The PC-MRI showed lower maximum velocity value and higher minimum velocity value than Doppler US. Therefore, PC-MRI demonstrates more obtuse time-velocity curve than Doppler US. In addition, the time- velocity curve of PC-MRI could be calibrated by introducing formulae that can convert each measurement value to a reference standard value within a 10% error. The PC-MRI can be used to estimate the Doppler US using this formula.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [22] Accuracy of Phase-Contrast Velocity Mapping Proximal and Distal to Stent Artifact During Cardiac Magnetic Resonance Imaging
    Avitabile, Catherine M.
    Harris, Matthew A.
    Doddasomayajula, Ravi S.
    Chopski, Steven G.
    Gillespie, Matthew J.
    Dori, Yoav
    Glatz, Andrew C.
    Fogel, Mark A.
    Whitehead, Kevin K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (12): : 1634 - 1638
  • [23] Reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging: a methodological issue
    Siamak Sabour
    Neuroradiology, 2016, 58 : 949 - 949
  • [24] Analysis of left-ventricular pathological flow via phase-contrast magnetic resonance imaging
    Unterhinninghofen, R
    Stehle, T
    Albers, J
    Hosch, W
    Vahl, C
    Dillmann, M
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1138 - 1143
  • [25] An approach to objective analysis of cerebrospinal fluid flow dynamics with phase-contrast magnetic resonance imaging
    Ucar, Murat
    Tokgoz, Nil
    ACTA NEUROCHIRURGICA, 2014, 156 (11) : 2207 - 2208
  • [26] An approach to objective analysis of cerebrospinal fluid flow dynamics with phase-contrast magnetic resonance imaging
    Murat Ucar
    Nil Tokgoz
    Acta Neurochirurgica, 2014, 156 : 2207 - 2208
  • [27] PHASE-CONTRAST MAGNETIC-RESONANCE ANGIOGRAPHY
    SOUZA, SP
    DUMOULIN, CL
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 514 - 515
  • [28] Numerical simulation of time-resolved 3D phase-contrast magnetic resonance imaging
    Puiseux, Thomas
    Sewonu, Anou
    Moreno, Ramiro
    Mendez, Simon
    Nicoud, Franck
    PLOS ONE, 2021, 16 (03):
  • [29] Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
    Julius Traber
    Lennart Wurche
    Matthias A. Dieringer
    Wolfgang Utz
    Florian von Knobelsdorff-Brenkenhoff
    Andreas Greiser
    Ning Jin
    Jeanette Schulz-Menger
    European Radiology, 2016, 26 : 986 - 996
  • [30] Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
    Traber, Julius
    Wurche, Lennart
    Dieringer, Matthias A.
    Utz, Wolfgang
    von Knobelsdorff-Brenkenhoff, Florian
    Greiser, Andreas
    Jin, Ning
    Schulz-Menger, Jeanette
    EUROPEAN RADIOLOGY, 2016, 26 (04) : 986 - 996