Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study

被引:3
|
作者
Park, Jieun [1 ]
Kim, Junghun [1 ]
Chang, Yongmin [2 ]
Youn, Sung Won [3 ]
Lee, Hui Joong [2 ]
Kang, Eun-Ju [4 ]
Lee, Ki-Nam [4 ]
Suchanek, Vojtech [2 ]
Hyun, Sinjae [5 ]
Lee, Jongmin [2 ]
机构
[1] Kyungpook Natl Univ, Dept Biomed Engn, Daegu, South Korea
[2] Kyungpook Natl Univ & Hosp, Dept Radiol, 50,Sam Duk 2 Ga, Daegu 700721, South Korea
[3] Catholic Univ Daegu, Dept Radiol, Med Ctr, Daegu, South Korea
[4] Dong A Univ, Dept Radiol, Coll Med, Busan, South Korea
[5] Mercer Univ, Dept Biomed Engn, Macon, GA 31207 USA
基金
新加坡国家研究基金会;
关键词
Pulsatile flow; time-velocity curve; flow analysis; phase-contrast magnetic resonance imaging; doppler ultrasonography; WALL SHEAR-STRESS; TRANSCRANIAL DOPPLER ULTRASOUND; COMMON CAROTID-ARTERY; CEREBRAL-BLOOD-FLOW; IN-VIVO; MR-ANGIOGRAPHY; VOLUME FLOW; QUANTIFICATION; VALIDATION; PATTERNS;
D O I
10.1080/24699322.2019.1649066
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this study was to analyze the characteristics of time-velocity curve acquired by phase-contrast magnetic resonance imaging (PC-MRI) using an in-vitro flow model as a reference for hemodynamic studies. The time- velocity curves of the PC-MRI were compared with Doppler ultrasonography (US) and also compared with those obtained in the electromagnetic flowmeter. The correlation between techniques was analyzed using an electromagnetic flowmeter as a reference standard; the maximum, minimum, and average velocities, full-width at half-maximum (FWHM), and ascending gradient (AG) were measured from time-velocity curves. The correlations between an electromagnetic flowmeter and the respective measurement technique for the PC-MRI and Doppler US were found to be high (mean R-2 > 0.9, p < 0.05). These results indicate that these measurement techniques are useful for measuring blood flow information and reflect actual flow. The PC-MRI was the best fit for the minimum velocity and FWHM, and the maximum velocity and AG were the best fit for Doppler US. The PC-MRI showed lower maximum velocity value and higher minimum velocity value than Doppler US. Therefore, PC-MRI demonstrates more obtuse time-velocity curve than Doppler US. In addition, the time- velocity curve of PC-MRI could be calibrated by introducing formulae that can convert each measurement value to a reference standard value within a 10% error. The PC-MRI can be used to estimate the Doppler US using this formula.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 50 条
  • [1] The analysis of the rf spoiling for phase-contrast magnetic resonance imaging
    Zou, Yun-Peng
    Fu, Chang-Xin
    Kang, Yan
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2015, 36 (05): : 631 - 635
  • [2] In vivo Velocity and Flow Errors Quantification by Phase-Contrast Magnetic Resonance Imaging
    Garcia, J.
    Kadem, L.
    Larose, E.
    Pibarot, P.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1377 - +
  • [3] PHASE-CONTRAST IN MAGNETIC-RESONANCE-IMAGING
    HILTBRAND, E
    BRIGUET, A
    HELVETICA PHYSICA ACTA, 1986, 59 (01): : 181 - 183
  • [4] MAGNETIC-RESONANCE VELOCITY IMAGING USING A FAST SPIRAL PHASE-CONTRAST SEQUENCE
    PIKE, GB
    MEYER, CH
    BROSNAN, TJ
    PELC, NJ
    MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (04) : 476 - 483
  • [5] ASSESSMENT OF APICO-AORTIC CONDUIT WITH PHANTOM-CORRECTED PHASE-CONTRAST MAGNETIC RESONANCE IMAGING
    Brofferio, A.
    Sarin, S.
    Woods, E. W.
    Woomert, C.
    Go, D.
    Shirani, J.
    Schiavone, W. A.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (03) : 525 - 525
  • [6] Noninterleaved Velocity Encodings for Improved Temporal and Spatial Resolution in Phase-Contrast Magnetic Resonance Imaging
    Hamilton, Craig A.
    Jordan, Jennifer H.
    Kraft, Robert A.
    Hundley, W. Gregory
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (04) : 570 - 574
  • [7] Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire
    Machida, Haruhiko
    Komori, Yoshiaki
    Ueno, Eiko
    Shen, Yun
    Hirata, Masami
    Kojima, Shinya
    Sato, Munekuni
    Okazaki, Takeshi
    Masukawa, Ai
    Morita, Satoru
    Suzuki, Kazufumi
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (08): : 571 - 577
  • [8] Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire
    Haruhiko Machida
    Yoshiaki Komori
    Eiko Ueno
    Yun Shen
    Masami Hirata
    Shinya Kojima
    Munekuni Sato
    Takeshi Okazaki
    Ai Masukawa
    Satoru Morita
    Kazufumi Suzuki
    Japanese Journal of Radiology, 2010, 28 : 571 - 577
  • [9] Numerical and experimental study of a novel phase contrast technique - Self reference phase-contrast magnetic resonance imaging
    Li, Longchuan
    Doyle, Mark
    Rayarao, Geetha
    Kortright, Eduardo
    Anayiotosl, Andreas S.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 313 - 314
  • [10] A Phantom Study to Characterize the Imaging Quality of a Phase-contrast Tomosynthesis Prototype
    Wu, Di
    Ghani, Muhammad U.
    Miao, Hui
    Li, Yuhua
    Chen, Wei R.
    Wu, Xizeng
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES VIII, 2013, 8582