Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom

被引:10
|
作者
Asl, Ruhollah Ghahraman [1 ]
Nasseri, Shahrokh [1 ,2 ]
Parach, Ali Asghar [3 ]
Zakavi, Seyed Rasoul [4 ]
Momennezhad, Mehdi [1 ,4 ]
Davenport, David [5 ]
机构
[1] Mashhad Univ Med Sci, Fac Med, Dept Med Phys, Mashhad, Iran
[2] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[3] Shahid Sadoughi Univ Med Sci, Fac Med, Dept Med Phys, Yazd, Iran
[4] Mashhad Univ Med Sci, Nucl Med Res Ctr, Mashhad, Iran
[5] Comprehens Canc Centers Nevada, Las Vegas, NV USA
关键词
Absorbed dose; GATE; RANDO phantom; Internal dosimetry; SIMULATION TOOLKIT; DOSE CALCULATIONS; S-VALUES; TLD; PATIENT; MODEL; TRANSPORT; ADULT; CODES;
D O I
10.1007/s13246-015-0367-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo techniques are widely employed in internal dosimetry to obtain better estimates of absorbed dose distributions from irradiation sources in medicine. Accurate 3D absorbed dosimetry would be useful for risk assessment of inducing deterministic and stochastic biological effects for both therapeutic and diagnostic radiopharmaceuticals in nuclear medicine. The goal of this study was to experimentally evaluate the use of Geant4 application for tomographic emission (GATE) Monte Carlo package for 3D internal dosimetry using the head portion of the RANDO phantom. GATE package (version 6.1) was used to create a voxel model of a human head phantom from computed tomography (CT) images. Matrix dimensions consisted of 319 x 216 x 30 voxels (0.7871 x 0.7871 x 5 mm(3)). Measurements were made using thermoluminescent dosimeters (TLD-100). One rod-shaped source with 94 MBq activity of Tc-99m was positioned in the brain tissue of the posterior part of the human head phantom in slice number 2. The results of the simulation were compared with measured mean absorbed dose per cumulative activity (S value). Absorbed dose was also calculated for each slice of the digital model of the head phantom and dose volume histograms (DVHs) were computed to analyze the absolute and relative doses in each slice from the simulation data. The S-values calculated by GATE and TLD methods showed a significant correlation (correlation coefficient, r (2) a parts per thousand yen 0.99, p < 0.05) with each other. The maximum relative percentage differences were a parts per thousand currency sign14 % for most cases. DVHs demonstrated dose decrease along the direction of movement toward the lower slices of the head phantom. Based on the results obtained from GATE Monte Carlopackage it can be deduced that a complete dosimetry simulation study, from imaging to absorbed dose map calculation, is possible to execute in a single framework.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 50 条
  • [1] Monte Carlo and experimental internal radionuclide dosimetry in RANDO head phantom
    Ruhollah Ghahraman Asl
    Shahrokh Nasseri
    Ali Asghar Parach
    Seyed Rasoul Zakavi
    Mehdi Momennezhad
    David Davenport
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 465 - 472
  • [2] Development of a Hybrid Multiscale Phantom for Monte Carlo Based Internal Dosimetry
    Marcatili, S.
    Villoing, D.
    Bardies, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S160 - S161
  • [3] Experimental Validation of Monte Carlo Simulations Based on a Virtual Source Model for TomoTherapy in a RANDO Phantom
    Yuan, Jiankui
    Zheng, Yiran
    Wessels, Barry
    Lo, Simon S.
    Ellis, Rodney
    Machtay, Mitchell
    Yao, Min
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : 796 - 804
  • [4] Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study
    Gear, J. I.
    Charles-Edwards, E.
    Partridge, M.
    Flux, G. D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (22): : 7273 - 7286
  • [5] Experimental Validation of Monte Carlo Simulations Based on a Virtual Source Model for Tomotherapy in a Rando Phantom
    Yuan, J.
    Albani, D.
    Zheng, Y.
    Wessels, B. W.
    Lo, S. S.
    Yao, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E608 - E608
  • [6] Experimental validation of Monte Carlo calculations with a voxelized Rando-Alderson phantom: a study on influence parameters
    Struelens, Lara
    Vanhavere, Filip
    Smans, Kristien
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5831 - 5844
  • [7] Monte Carlo model of the female RANDO phantom irradiation with an Elekta Precise linear accelerator
    Abella, V.
    Miro, R.
    Juste, B.
    Santos, A.
    Verdu, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 230 - 233
  • [8] Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom
    Wyatt, M
    Corredor, C
    Tamimi, M
    Miller, LF
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 461 - 465
  • [9] Validation of irtGPUMCD, a GPU-based Monte Carlo internal dosimetry framework for radionuclide therapy
    Frezza, Andrea
    Joachim-Paquet, Charles
    Chauvin, Maxime
    Despres, Philippe
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 95 - 104
  • [10] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662