In vivo wear of enamel by a lithia disilicate-based core ceramic used for posterior fixed partial dentures: First-year results

被引:0
|
作者
Esquivel-Upshaw, Josephine F.
Young, Henry
Jones, Jack
Yang, Mark
Anusavice, Kenneth J.
机构
[1] Univ Florida, Dept Prosthodont, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Operat Dent, Gainesville, FL USA
[3] Univ Florida, Dept Biostat, Gainesville, FL USA
[4] Univ Florida, Dept Biomat, Gainesville, FL USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed (1) to test the hypothesis that no significant relationship exists between the magnitude of occlusal clenching force and wear rates of enamel opposing a new core ceramic (e.max Press, Ivoclar Vivadent) used in posterior fixed partial dentures (FPDs); and (2) to test the hypothesis that mean annual enamel wear by an experimental core ceramic is comparable to the mean annual enamel wear by enamel of 38 mu m. Materials and Methods: Baseline data were obtained for patients in addition to preliminary impressions of maxillary and mandibular teeth. Thirty ceramic FPDs were processed from a new core ceramic (e.max Press) that was hot pressed and glazed. Patients were recalled 1 year after cementation and evaluated using clinical criteria that included wear assessment of opposing teeth. Impressions were made of the opposing teeth with polyvinyl siloxane impression material and photographs were taken of intraoral occlusal contacts marked with articulating ribbon. Baseline casts and casts made at each recall exam of opposing dentitions were scanned using a 3-dimensional laser scanner (Laserscan 3D, Willytec) and evaluated for wear. A total of 21 occlusal surfaces were analyzed for the presence of wear. Results: Statistical analysis using a linear and quadratic model revealed no significant relationship between occlusal forces and wear rate assuming either a linear model (R-2 = 0.018) or a quadratic model (R-2 = 0.023). The maximum annual wear of enamel by the glazed core ceramic (e.max Press) was 88.3 mu m, which is significantly greater than the annual enamel-by-enamel wear of 38 mu m (P <.0001). Conclusion: Further analysis with a larger sample size is needed to determine the relationship between occlusal clenching force and wear rate and the influence of other factors that cause increased wear of enamel by opposing ceramic restorations.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 6 条
  • [1] Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures
    Esquivel-Upshaw, Josephine F.
    Young, Henry
    Jones, Jack
    Yang, Mark
    Anusavice, Kenneth J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (02) : 155 - 160
  • [2] Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs
    Esquivel-Upshaw, JF
    Anusavice, KJ
    Young, H
    Jones, J
    Gibbs, C
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2004, 17 (04) : 469 - 475
  • [3] Two-year clinical evaluation of lithia-disilicate-based all-ceramic crowns and fixed partial dentures
    Taskonak, Burak
    Sertgoez, Atilla
    [J]. DENTAL MATERIALS, 2006, 22 (11) : 1008 - 1013
  • [4] Survival Rates of a Lithium Disilicate-Based Core Ceramic for Three-Unit Esthetic Fixed Partial Dentures: A 10-Year Prospective Study
    Fernanda Sola-Ruiz, M.
    Lagos-Flores, Elena
    Luis Roman-Rodriguez, Juan
    Del Rio Highsmith, Jaime
    Fons-Font, Antonio
    Granell-Ruiz, Maria
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 175 - 180
  • [5] In vivo wear of enamel by a core ceramic used for posterior FPDs.
    Esquivel-Upshaw, J.
    Anusavice, K. J.
    Young, H.
    Jones, J.
    Gibbs, C.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B340 - B340
  • [6] 3-year clinical results of zirconia posterior fixed partial dentures made Direct Ceramic Machining (DCM).
    Sailer, I.
    Luethy, H.
    Feher, A.
    Schumacher, M.
    Schaerer, P.
    Hammerle, C. H. F.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B21 - B21