Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs

被引:0
|
作者
Esquivel-Upshaw, JF
Anusavice, KJ
Young, H
Jones, J
Gibbs, C
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Gen Dent, San Antonio, TX 78229 USA
[2] Univ Florida, Dept Oral Biol, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Prosthodont, Gainesville, FL 32610 USA
[4] Univ Florida, Dept Operat Dent, Gainesville, FL 32610 USA
[5] Univ Florida, Dept Biomat, Gainesville, FL 32610 USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this research project was to determine the clinical success rate of a lithia disilicate-based core ceramic for use in posterior fixed partial dentures (FPD) as a function of bite force, cement type, connector height, and connector width. Materials and Methods: Thirty ceramic FPD core frameworks were prepared using a heat-pressing technique and a lithia disilicate-based core ceramic. The maximum clenching force was measured for each patient prior to tooth preparation. Connector height and width were measured for each FPD. Patients were recalled yearly after cementation for 2 years and evaluated using 11 clinical criteria, All FPDs were examined by two independent clinicians, and rankings from 1 to 4 were made for each criterion (4 = excellent; 1 = unacceptable). Results: Two of the 30 ceramic FPDs fractured within the 2-year evaluation period, representing a 93% success rate. One fracture was associated with a low occlusal force and short connector height (2.9 mm). The other fracture was associated with the greatest occlusal force (1,031 N) and adequate connector height. All criteria were ranked good to excellent during the 2-year recall for all remaining FPDs. Conclusion: The performance of the experimental core ceramic in posterior FPDs was promising, with only a 7% fracture rate after 2 years. Because of the limited sample size, it is not possible to identify the maximum clenching force that is allowable to prevent fracture caused by interocclusal forces.
引用
收藏
页码:469 / 475
页数:7
相关论文
共 36 条
  • [1] Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures
    Esquivel-Upshaw, Josephine F.
    Young, Henry
    Jones, Jack
    Yang, Mark
    Anusavice, Kenneth J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2008, 21 (02) : 155 - 160
  • [2] Work of adhesion of resin on treated lithia disilicate-based ceramic
    Della Bona, A
    Shen, CY
    Anusavice, KJ
    [J]. DENTAL MATERIALS, 2004, 20 (04) : 338 - 344
  • [3] Survival Rates of a Lithium Disilicate-Based Core Ceramic for Three-Unit Esthetic Fixed Partial Dentures: A 10-Year Prospective Study
    Fernanda Sola-Ruiz, M.
    Lagos-Flores, Elena
    Luis Roman-Rodriguez, Juan
    Del Rio Highsmith, Jaime
    Fons-Font, Antonio
    Granell-Ruiz, Maria
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 175 - 180
  • [4] In vivo wear of enamel by a lithia disilicate-based core ceramic used for posterior fixed partial dentures: First-year results
    Esquivel-Upshaw, Josephine F.
    Young, Henry
    Jones, Jack
    Yang, Mark
    Anusavice, Kenneth J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (04) : 391 - 396
  • [5] Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs
    von Steyern, PV
    Jönsson, O
    Nilner, K
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2001, 14 (04) : 379 - 384
  • [6] Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns
    Suputtamongkol, Kallaya
    Anusavice, Kenneth J.
    Suchatlampong, Chatcharee
    Sithiamnuai, Phira
    Tulapornchai, Chantana
    [J]. DENTAL MATERIALS, 2008, 24 (05) : 667 - 673
  • [7] In vivo performance of an experimental core ceramic for posterior FPDs.
    Esquivel-Upshaw, J
    Anusavice, KJ
    Young, H
    Jones, J
    Yang, M
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : A331 - A331
  • [8] INFLUENCE OF THE TYPE OF POST AND CORE ON IN VITRO MARGINAL CONTINUITY, FRACTURE RESISTANCE, AND FRACTURE MODE OF LITHIA DISILICATE-BASED ALL-CERAMIC CROWNS
    Forberger, Nicole
    Goehring, Till N.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (04): : 264 - 273
  • [9] Clinical Evaluation of All-Ceramic Posterior Three-Unit FDPs Made of In-Ceram Zirconia
    Eschbach, Stephanie
    Wolfart, Stefan
    Bohlsen, Frank
    Kern, Matthias
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (05) : 490 - 492
  • [10] The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
    Raigrodski, Ariel J.
    Chiche, Gerard J.
    Potiket, Narong
    Hochstedler, J. L.
    Mohamed, Shawky E.
    Billiot, Susan
    Mercante, Donald E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (04): : 237 - 244