High-energy X-ray diffraction using the Pixium 4700 flat-panel detector

被引:73
|
作者
Daniels, J. E. [1 ]
Drakopoulos, M. [2 ]
机构
[1] European Synchrotron Radiat Facil, ID15, F-38043 Grenoble, France
[2] Diamond Light Source, I12, Oxford, England
关键词
high-energy X-rays; flat-panel detector; Pixium detector; diffraction; large area detectors; detector noise; MAR image plate;
D O I
10.1107/S0909049509015519
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Pixium 4700 detector represents a significant step forward in detector technology for high-energy X-ray diffraction. The detector design is based on digital flat-panel technology, combining an amorphous Si panel with a CsI scintillator. The detector has a useful pixel array of 1910 X 2480 pixels with a pixel size of 154 mm X 154 mm, and thus it covers an effective area of 294 mm X 379 mm. Designed for medical imaging, the detector has good efficiency at high X-ray energies. Furthermore, it is capable of acquiring sequences of images at 7.5 frames per second in full image mode, and up to 60 frames per second in binned region of interest modes. Here, the basic properties of this detector applied to high-energy X-ray diffraction are presented. Quantitative comparisons with a widespread high-energy detector, the MAR345 image plate scanner, are shown. Other properties of the Pixium 4700 detector, including a narrow point-spread function and distortion-free image, allows for the acquisition of high-quality diffraction data at high X-ray energies. In addition, high frame rates and shutterless operation open new experimental possibilities. Also provided are the necessary data for the correction of images collected using the Pixium 4700 for diffraction purposes. (C) 2009 International Union of Crystallography Printed in Singapore - all rights reserved
引用
收藏
页码:463 / 468
页数:6
相关论文
共 50 条
  • [21] The use of a flat-panel detector for seven-beam x-ray coherent scatter imaging
    Foran, Kelly A.
    Johns, Paul C.
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4377 - 4377
  • [22] X-ray flat-panel detector geometry correction to improve dimensional computed tomography measurements
    Luethi, Melina
    Bircher, Benjamin A.
    Meli, Felix
    Kueng, Alain
    Thalmann, Rudolf
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (03)
  • [23] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [24] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    [J]. Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [25] Development of an X-ray imaging detector for high-energy X-ray microtomography
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 934 - 940
  • [26] Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
    Han, Jong Chul
    Kim, Ho Kyung
    Kim, Dong Woon
    Yun, Seungman
    Youn, Hanbean
    Kam, Soohwa
    Tanguay, Jesse
    Cunningham, Ian A.
    [J]. CURRENT APPLIED PHYSICS, 2014, 14 (12) : 1734 - 1742
  • [27] High-energy x-ray and neutron CMOS detector
    Mandelis, Andreas
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09):
  • [28] Focusing optics for high-energy X-ray diffraction
    Lienert, U
    Schulze, C
    Honkimaki, V
    Tschentscher, T
    Garbe, S
    Hignette, O
    Horsewell, A
    Lingham, M
    Poulsen, HF
    Thomsen, NB
    Ziegler, E
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 226 - 231
  • [29] An X-ray tomograph based on a flat panel detector
    Constantin, F.
    Pavel, C.
    Bugoi, R.
    Toderas, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 685 - 689
  • [30] Flat-panel X-ray detector using amorphous silicon technology - Reduced radiation dose for the detection of foreign bodies
    Volk, M
    Strotzer, M
    Gmeinwieser, J
    Alexander, J
    Frund, R
    Seitz, J
    Manke, C
    Spahn, M
    Feuerbach, S
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (07) : 373 - 377