Development and heat transfer analysis of thermoelectric self-powered fuel-fired residential boiler

被引:3
|
作者
Xiao, Heng [1 ,2 ,4 ]
Qiu, Kuanrong [3 ]
Gou, Xiaolong [4 ]
Liu, Xiaobing [1 ,2 ]
Li, Zhenggui [1 ,2 ]
机构
[1] Xihua Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Fluid & Power Machinery, Chengdu 610039, Sichuan, Peoples R China
[2] Xihua Univ, Sch Energy & Power Engn, Key Lab Fluid Machinery & Engn, Chengdu, Sichuan, Peoples R China
[3] Nat Resources Canada, Canmet ENERGY, Ottawa, ON, Canada
[4] Chongqing Univ, Sch Energy & Power Engn, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
boiler; self-powered; thermal resistance analysis; thermoelectric generation; WASTE HEAT; PERFORMANCE; GENERATOR; OPTIMIZATION; ENTRANSY; SYSTEM;
D O I
10.1002/ese3.1222
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solid-state thermoelectric (TE) devices offer many interesting features compared with other methods of generation, such as no moving parts, high reliability, low maintenance, and straightforward integration with other heating equipment. In this study, a thermoelectric assembly was integrated into a residential heating boiler to convert a portion of combustion heat to electricity while meeting space and/or water heating needs. A prototype was developed, in which recently developed thermoelectric modules were incorporated into a gas-fired boiler. The electricity generated by the thermoelectric assembly would be sufficient to power the electrical auxiliary components of the heating system. In this way, the heating system could operate entirely on fuel combustion and provide the consumer with heating system reliability and a reduction in power consumption. A model for the thermoelectric conversion system was established and the thermal resistance analysis was carried out to show the influence of heat transfer coefficients and other parameters on power output and efficiency, and thus improve the system design. In this study, the single-module integrated assembly can produce a 22.5 W power output. However, each module of the four-/eight-module integrated assembly can only generate a power output of 7.85/9.175 W on average. The performance of a single module in a multimodule assembly is worse than that of a single module assembly. The number of modules placed on the furnace wall is not as many as possible but has an optimal value. In this experimental environment, the assembly of eight modules is the optimal choice. Furthermore, it is found that enhancing combustion-side heat transfer capacity is an effective way to promote system performance. The power output of the assembly composed of four modules will increase by 70% from 7.85 to 13.5 W due to the installation of the fin on the hot end.
引用
收藏
页码:3344 / 3357
页数:14
相关论文
共 38 条
  • [31] Development of miniature self-powered single-chamber microbial fuel cell and its response mechanism to copper ions in high and trace concentration
    Yang, Shasha
    Xiao, Nan
    Wang, Jingshu
    Zhang, Beichen
    Huang, Jinhui Jeanne
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 834
  • [32] FIRESIDE DEPOSITS AND THEIR EFFECT ON HEAT TRANSFER IN A PULVERIZED-FUEL-FIRED BOILER .3. INFLUENCE OF PHYSICAL CHARACTERISTICS OF DEPOSIT ON ITS RADIANT EMITTANCE AND EFFECTIVE THERMAL CONDUCTANCE
    BOOW, J
    GOARD, PRC
    JOURNAL OF THE INSTITUTE OF FUEL, 1969, 42 (346): : 412 - &
  • [33] Determination of the Metallic Coating Properties Obtained by Thermal Spraying and Analysis of its Influence on the Heat Transfer Efficiency in the Thermoelectric Power Plant Boiler Tubes
    de Campos, Pamella Kesseler
    Cardoso, Bruno Reis
    Furtado, Heloisa Cunha
    Ramos, Vitor Santos
    Pimenta, Andre Rocha
    Diniz, Marilia Garcia
    SOLDAGEM & INSPECAO, 2022, 27
  • [34] Development of a general circumferentially nonuniform heat transfer fuel rod model for subchannel analysis and application to helical fuel rods
    Junsen FU
    Junlong LI
    Xiaowen WANG
    Qi ZHANG
    Yao XIAO
    Hanyang GU
    Science China(Technological Sciences), 2025, 68 (02) : 19 - 30
  • [35] Development of a recovery boiler lower furnace heat transfer model .1. Analysis of floor tube temperature excursions
    Agranat, V
    Kawaji, M
    Tran, H
    ENGINEERING & PAPERMAKERS: FORMING BONDS FOR BETTER PAPERMAKING, BOOKS 1-3, 1997, : 1131 - 1139
  • [36] Development of a Weighted-Sum-of-Gray-Gases Model for Modeling Radiative Heat Transfer in Coal-Fired Oxy-Fuel Boilers
    Kez, V.
    Consalvi, J. -L.
    Liu, F.
    Koch, M.
    Hatzfeld, O.
    Kneer, R.
    PROCEEDINGS OF THE 9TH INTERNATIONAL SYMPOSIUM ON RADIATIVE TRANSFER, RAD 2019, 2019, : 431 - 438
  • [37] DEVELOPMENT OF THREE-DIMENSIONAL NUMERICAL ANALYSIS METHOD OF BOILER FURNACE CHARACTERISTICS - PART 2: COMBUSTION AND HEAT TRANSFER ANALYSIS.
    Sakai, Masayasu
    Nakashima, Fumiya
    Tokuda, Kimishiro
    Asayama, Hideki
    Ide, Yuichi
    Aiki, Hidetoshi
    Technical Review - Mitsubishi Heavy Industries, 1984, 21 (01): : 24 - 34