Transcranial Doppler ultrasound using adaptive beamforming technique for the suppression of high-intensity interferences

被引:1
|
作者
Okumura, Shigeaki [1 ]
Taki, Hirofumi [1 ]
Sato, Toru [1 ]
Kita, Aya [2 ]
机构
[1] Kyoto Univ, Kyoto, Japan
[2] Sakai Rumi Clin, Hyogo, Japan
关键词
Transcranial Doppler ultrasound; blood flow velocity estimation; spatial domain interferometry; adaptive beamforming; Capon method; SUBARACHNOID HEMORRHAGE; VASOSPASM; ANGIOGRAPHY;
D O I
10.1109/ULTSYM.2013.0375
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The control of vasospasm is important in postoperative management after the occurrence of subarachnoid hemorrhage. Transcranial Doppler ultrasound (TCD) is a diagnostic safety test that measures the blood flow in the cranium; however, TCD has low reliability because of the high-intensity interference returned from the cranium. In this study, we employed two techniques to suppress interferences. First, we used a moving target indicator (MTI) filter that suppresses echoes from undesired stationary targets. Second, we applied spatial domain interferometry with the Capon method to the signal after MTI filtering. The desired signal from red blood cells is supposed to have a low correlation with the interferences from undesired stationary targets. We thus averaged the covariance matrix to range direction without averaging sub-matrices in the diagonal direction. In a simulation study, we succeeded in estimating blood flow velocity with an average estimation velocity error of 0.2 m/s, where the desired signal intensity from red blood cells is 60 dB lower than the cranium interference intensity. The center frequency of the pulse is 2.0 MHz and the pulse length is 5 mu s. These results indicate the high potential of the proposed method for improving the estimation accuracy of blood flow velocity in the cranium.
引用
收藏
页码:1472 / 1475
页数:4
相关论文
共 50 条
  • [31] High-intensity focused ultrasound beam path visualization using ultrasound imaging
    Song, Jae Hee
    Chang, Jin Ho
    Yoo, Yang Mo
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2020, 39 (01): : 16 - 23
  • [32] PROCESSING RESIN MATRIX COMPOSITES USING HIGH-INTENSITY ULTRASOUND
    GRAHAM, LJ
    AHLBERG, LA
    COHENTENOUDJI, F
    TITTMANN, BR
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1987, 34 (03) : 410 - 410
  • [33] Monitoring of high-intensity focused ultrasound lesion formation using decorrelation between high-speed ultrasonic images by parallel beamforming
    Sasaki, Shoya
    Takagi, Ryo
    Matsuura, Keiko
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [34] Monitoring of high-Intensity focused ultrasound lesion formation using decorrelation between high-speed ultrasonic images by parallel beamforming
    Sasaki, Shoya
    Takagi, Ryo
    Matsuura, Keiko
    Yoshizawa, Shin
    Umemura, Shin-Ichiro
    Japanese Journal of Applied Physics, 2014, 53 (7 SPEC. ISSUE)
  • [35] Design of a high-intensity ultrasound reactor
    Johansson, Orjan
    Pamidi, Taraka
    Lofqvist, Torbjorn
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [36] Design of high-intensity ultrasound reactor
    Johansson, Orjan
    Lofqvist, Torbjorn
    Pamidi, Taraka Rama Krishna
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [37] High-intensity focussed ultrasound (HIFU)
    Hunold, Peter
    Hoellen, F.
    Beldoch, M. P.
    Eckey, T.
    Bohlmann, M. K.
    GYNAKOLOGISCHE ENDOKRINOLOGIE, 2015, 13 (04): : 238 - 244
  • [38] SYMPOSIUM ON THE APPLICATIONS OF HIGH-INTENSITY ULTRASOUND
    WILTSHIRE, MF
    ULTRASONICS, 1990, 28 (05) : 338 - 338
  • [39] Degassing of milk by high-intensity ultrasound
    Villamiel, M
    Verdurmen, R
    de Jong, P
    MILCHWISSENSCHAFT-MILK SCIENCE INTERNATIONAL, 2000, 55 (03): : 123 - 125
  • [40] High-intensity focused ultrasound and cryotherapy
    Murat, F. J.
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 78 : S11 - S11