Mixed convective heat transfer through a horizontal opening in a full-scale, two-story test-hut

被引:3
|
作者
Vera, Sergio [1 ,2 ]
Rao, Jiwu [3 ]
Fazio, Paul [3 ]
Campo, Antonio [4 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Construct Engn & Management, Sch Engn, Santiago 7820436, RM, Chile
[2] Pontificia Univ Catolica Chile, Ctr Sustainable Urban Dev CEDEUS, Santiago 7820436, RM, Chile
[3] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
[4] Univ Texas San Antonio, Dept Mech Engn, San Antonio, TX 78249 USA
关键词
Horizontal opening; Mixed convection; Heat transfer; Full scale two-story test-hut; CFD; DRIVEN FLOW-THROUGH; NATURAL-CONVECTION; AIR-FLOW; BUOYANCY; VENTILATION; PRESSURE; CAVITY; PLATE; MODEL;
D O I
10.1016/j.applthermaleng.2013.12.039
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper undertakes a study to investigate the heat transfer through a horizontal opening connecting two rooms in a full-scale two-story test-hut with two ventilation strategies, namely ventilation with downward net flow through the opening and independent balanced ventilation in each room. The horizontal opening represents a stairwell opening in buildings. The airflow in the test-hut is characterized by 1.44 x 10(5) <= Gr <= 7.66 x 10(6) and Re <= 2782. Based on the simulation of 74 cases using a CFD model, all heat fluxes through the opening are calculated for each case under study. The collection of results demonstrates that upward heat fluxes through the opening are proportional to the temperature difference between the lower and the upper rooms. Heat fluxes were even found when the upper room is warmer than the lower room due to the presence of local eddies under and above the opening. It was also found that the heat transfer through the opening is caused mainly by buoyancy driven flows with some contribution from forced flows. This means that mixed convective heat transfer occurs through the opening and the combined effect can be predicted by the empirical correlation of power-law form Nu = 3.11Gr(0.057)Re(0.63). (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 45 条
  • [41] The local heat transfer characteristics associated with mixed convective developing flow through a horizontal tube exposed to a uniform wall temperature boundary condition
    Coetzee, Mark J.
    Steyn, Deniel
    Everts, Marilize
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 203
  • [42] Full-Scale Seismic Performance Testing of a Predamaged Two-Story Traditional Timber Frame on a Slope Reinforced Using Viscoelastic Dampers (vol 105, 10.1061/JS']JSENDH.STENG-12843, 2024)
    Yi, Duhang
    Yuan, Jiacong
    Pan, Yi
    Fan, Yuanqing
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (10)
  • [43] Impact of size and location of outflow opening vent on mixed convective heat transfer induced by two aligned heated cylinders immersed in a partially open channel
    Alomar, Omar Rafae
    Saaeed, Renas Hassan
    Ali, Omar Mohammed
    HEAT TRANSFER, 2023, 52 (04) : 3187 - 3226
  • [44] Convective boiling heat transfer and two-phase flow characteristics inside a small horizontal helically coiled tubing once-through steam generator
    Zhao, L
    Guo, LJ
    Bai, BF
    Hou, YC
    Zhang, XM
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (25) : 4779 - 4788
  • [45] Full-scale 3-D finite element modeling of a two-loop pressurized water reactor for heat transfer, thermal-mechanical cyclic stress analysis, and environmental fatigue life estimation
    Mohanty, Subhasish
    Soppet, William K.
    Majumdar, Saurindranath
    Natesan, Krishnamurti
    NUCLEAR ENGINEERING AND DESIGN, 2015, 295 : 374 - 387