Mixed convective heat transfer through a horizontal opening in a full-scale, two-story test-hut

被引:3
|
作者
Vera, Sergio [1 ,2 ]
Rao, Jiwu [3 ]
Fazio, Paul [3 ]
Campo, Antonio [4 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Construct Engn & Management, Sch Engn, Santiago 7820436, RM, Chile
[2] Pontificia Univ Catolica Chile, Ctr Sustainable Urban Dev CEDEUS, Santiago 7820436, RM, Chile
[3] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ H3G 1M8, Canada
[4] Univ Texas San Antonio, Dept Mech Engn, San Antonio, TX 78249 USA
关键词
Horizontal opening; Mixed convection; Heat transfer; Full scale two-story test-hut; CFD; DRIVEN FLOW-THROUGH; NATURAL-CONVECTION; AIR-FLOW; BUOYANCY; VENTILATION; PRESSURE; CAVITY; PLATE; MODEL;
D O I
10.1016/j.applthermaleng.2013.12.039
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper undertakes a study to investigate the heat transfer through a horizontal opening connecting two rooms in a full-scale two-story test-hut with two ventilation strategies, namely ventilation with downward net flow through the opening and independent balanced ventilation in each room. The horizontal opening represents a stairwell opening in buildings. The airflow in the test-hut is characterized by 1.44 x 10(5) <= Gr <= 7.66 x 10(6) and Re <= 2782. Based on the simulation of 74 cases using a CFD model, all heat fluxes through the opening are calculated for each case under study. The collection of results demonstrates that upward heat fluxes through the opening are proportional to the temperature difference between the lower and the upper rooms. Heat fluxes were even found when the upper room is warmer than the lower room due to the presence of local eddies under and above the opening. It was also found that the heat transfer through the opening is caused mainly by buoyancy driven flows with some contribution from forced flows. This means that mixed convective heat transfer occurs through the opening and the combined effect can be predicted by the empirical correlation of power-law form Nu = 3.11Gr(0.057)Re(0.63). (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:499 / 507
页数:9
相关论文
共 45 条
  • [1] Interzonal air and moisture transport through large horizontal openings in a full-scale two-story test-hut: Part 2-CFD study
    Vera, S.
    Fazio, P.
    Rao, J.
    BUILDING AND ENVIRONMENT, 2010, 45 (03) : 622 - 631
  • [2] Interzonal air and moisture transport through large horizontal openings in a full-scale two-story test-hut: Part 1-Experimental study
    Vera, S.
    Fazio, P.
    Rao, J.
    BUILDING AND ENVIRONMENT, 2010, 45 (05) : 1192 - 1201
  • [3] SHAKING TABLE TEST OF FULL-SCALE TWO-STORY WOODEN FRAMES WITH SLIDING BASE
    Tomita A.
    Miyazu Y.
    Tojo T.
    Aoki T.
    Wakita T.
    Nagano M.
    Journal of Structural and Construction Engineering, 2024, 89 (816): : 168 - 179
  • [4] CONVECTIVE HEAT-TRANSFER COEFFICIENTS FROM A FULL-SCALE TEST IN THE REPEAT FACILITY
    KAHWAJI, G
    BURNS, PJ
    WINN, CB
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1989, 111 (02): : 132 - 137
  • [5] Full-scale experiments on smoke movement in a two-story detached house with two horizontal openings at the lower-floor ceiling
    Hu, Haowei
    Li, Hang
    Qi, Zhenyao
    Shi, Jingjun
    Ji, Jie
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [6] Cyclic full-scale test of a two-story special steel beam-through braced frame for industrialized steel residential house
    Zhou, Qing
    Wang, Wei
    Chen, Yiyi
    Tong, Lewei
    STESSA 2012: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2012, : 387 - 393
  • [7] A novel method for full-scale measurement of the external convective heat transfer coefficient for building horizontal roof
    Shao, Jiantao
    Liu, Jing
    Zhao, Jianing
    Zhang, Wenwu
    Sun, Dexing
    Fu, Zhipeng
    ENERGY AND BUILDINGS, 2009, 41 (08) : 840 - 847
  • [8] Cyclic performance of full-scale two-story narrow steel plate shear walls
    Li, Chao-Hsien
    Tsai, Keh-Chyuan
    Lin, Chih-Han
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 153 - +
  • [9] FULL SCALE TEST ON A TWO-STORY HOUSE SUBJECTED TO LATERAL LOAD.
    Yokel, Felix Y.
    Hsi, George C.
    Somes, Norman F.
    National Bureau of Standards, Building Science Series, 1973, (44):
  • [10] Full-scale tests on two-story SCBFs with Through-Gusset Plate in brace-to-CFT column connections
    Ebrahimi, Samira
    Mirghaderi, Seyed Rasoul
    Zahrai, Seyed Mehdi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 187