Visualization of different anatomical parts of the enucleated human eye using X-ray micro-CT imaging

被引:12
|
作者
Tkachev, Sergey Y. [1 ]
Mitrin, Boris I. [2 ]
Karnaukhov, Nikolay S. [1 ]
Sadyrin, Evgeniy V. [2 ]
Voloshin, Mark V. [3 ]
Maksimov, Alexey Y. [1 ]
Goncharova, Anna S. [1 ]
Lukbanova, Ekaterina A. [1 ]
Zaikina, Ekaterina V. [1 ]
Volkova, Anastasiya V. [1 ]
Khodakova, Darya V. [1 ]
Mindar, Maria V. [1 ]
Yengibarian, Marina A. [1 ]
Protasova, Tatyana P. [1 ]
Kit, Sergey O. [1 ]
Ermakov, Alexey M. [2 ]
Chapek, Sergey V. [2 ]
Tkacheva, Marina S. [1 ]
机构
[1] Natl Med Res Ctr Oncol, Rostov Na Donu, Russia
[2] Don State Tech Univ, Rostov Na Donu, Russia
[3] Rostov State Med Univ, Rostov Na Donu, Russia
关键词
D O I
10.1016/j.exer.2020.108394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Micro-CT visualization allows reconstruction of eye structures with the resolution of light microscopy and estimation of tissue densities. Moreover, this method excludes damaging procedures and allows further histological staining due to the similar steps in the beginning. We have shown the feasibility of the lab-based micro-CT machine usage for visualization of clinically important compartments of human eye such as trabecular outflow pathway, retina, iris and ciliary body after pre-treatment with iodine in ethanol. We also identified the challenges of applying this contrasting technique to lens, cornea, and retina and proposed alternative staining methods for these tissues. Thereby this work provides a starting point for other studies for imaging of human eyes in normal and pathological conditions using lab-based micro-CT systems.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] An experimental micro-CT system for X-ray NDT
    Rossi, M
    Casali, F
    Bettuzzi, M
    Morigi, MP
    Romani, A
    Golovkin, SV
    Govorun, VN
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 338 - 348
  • [12] X-ray micro-CT with a displaced detector array
    Wang, G
    MEDICAL PHYSICS, 2002, 29 (07) : 1634 - 1636
  • [13] Methodological Refinements to Using Lugol's Iodine as a Contrast Agent in X-ray Micro-CT Imaging
    Gignac, P. M.
    Kley, N. J.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2013, 53 : E77 - E77
  • [14] Whole-Body Imaging of a Hypercholesterolemic Female Zebrafish by Using Synchrotron X-Ray Micro-CT
    Seo, Eunseok
    Lim, Jae-Hong
    Seo, Seung Jun
    Lee, Sang Joon
    ZEBRAFISH, 2015, 12 (01) : 11 - 20
  • [15] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [16] Time-optimized X-ray micro-CT imaging of polymer based scaffolds
    Morris, David E.
    Mather, Melissa L.
    Simon, Carl G., Jr.
    Crowe, John A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) : 360 - 367
  • [17] Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms
    Alona Keren-Paz
    Vlad Brumfeld
    Yaara Oppenheimer-Shaanan
    Ilana Kolodkin-Gal
    npj Biofilms and Microbiomes, 4
  • [18] Micro-CT X-ray imaging exposes structured diffusion barriers within biofilms
    Keren-Paz, Alona
    Brumfeld, Vlad
    Oppenheimer-Shaanan, Yaara
    Kolodkin-Gal, Ilana
    NPJ BIOFILMS AND MICROBIOMES, 2018, 4
  • [19] A reconstruction of the lophophore of Devonian rhynchonellids (Brachiopoda) by using X-Ray micro-CT
    A. V. Pakhnevich
    Paleontological Journal, 2017, 51 : 143 - 154
  • [20] A Reconstruction of the Lophophore of Devonian Rhynchonellids (Brachiopoda) by Using X-Ray Micro-CT
    Pakhnevich, A. V.
    PALEONTOLOGICAL JOURNAL, 2017, 51 (02) : 143 - 154