Visualization of different anatomical parts of the enucleated human eye using X-ray micro-CT imaging

被引:12
|
作者
Tkachev, Sergey Y. [1 ]
Mitrin, Boris I. [2 ]
Karnaukhov, Nikolay S. [1 ]
Sadyrin, Evgeniy V. [2 ]
Voloshin, Mark V. [3 ]
Maksimov, Alexey Y. [1 ]
Goncharova, Anna S. [1 ]
Lukbanova, Ekaterina A. [1 ]
Zaikina, Ekaterina V. [1 ]
Volkova, Anastasiya V. [1 ]
Khodakova, Darya V. [1 ]
Mindar, Maria V. [1 ]
Yengibarian, Marina A. [1 ]
Protasova, Tatyana P. [1 ]
Kit, Sergey O. [1 ]
Ermakov, Alexey M. [2 ]
Chapek, Sergey V. [2 ]
Tkacheva, Marina S. [1 ]
机构
[1] Natl Med Res Ctr Oncol, Rostov Na Donu, Russia
[2] Don State Tech Univ, Rostov Na Donu, Russia
[3] Rostov State Med Univ, Rostov Na Donu, Russia
关键词
D O I
10.1016/j.exer.2020.108394
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Micro-CT visualization allows reconstruction of eye structures with the resolution of light microscopy and estimation of tissue densities. Moreover, this method excludes damaging procedures and allows further histological staining due to the similar steps in the beginning. We have shown the feasibility of the lab-based micro-CT machine usage for visualization of clinically important compartments of human eye such as trabecular outflow pathway, retina, iris and ciliary body after pre-treatment with iodine in ethanol. We also identified the challenges of applying this contrasting technique to lens, cornea, and retina and proposed alternative staining methods for these tissues. Thereby this work provides a starting point for other studies for imaging of human eyes in normal and pathological conditions using lab-based micro-CT systems.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Imaging of metallic foams using X-ray micro-CT
    Saadatfar, M.
    Garcia-Moreno, F.
    Hutzler, S.
    Sheppard, A. P.
    Knackstedt, M. A.
    Banhart, J.
    Weaire, D.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 344 (1-3) : 107 - 112
  • [2] X-ray micro-CT measurement of large parts at very low temperature
    Koutecky, T.
    Zikmund, T.
    Glittova, D.
    Palousek, D.
    Zivcak, J.
    Kaiser, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (03):
  • [3] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [4] Effect of experimental parameters on X-ray Micro-CT imaging for Spectral CT applications
    Lima, Mateus Gruener
    Jussiani, Eduardo Inocente
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [5] Using X-ray micro-CT imaging to monitor dissolution of macroporous bioactive glass scaffolds
    Jones, JR
    Milroy, GE
    Cameron, RE
    Bonfield, W
    Hench, LL
    BIOCERAMICS 17, 2005, 284-286 : 493 - 496
  • [6] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [7] X-ray strain tensor imaging: FEM simulation and experiments with a micro-CT
    Kim, Jae G.
    Park, So E.
    Lee, Soo Y.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 63 - 75
  • [8] A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT
    Ghanavati, Sahar
    Yu, Lisa X.
    Lerch, Jason P.
    Sled, John G.
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 221 : 70 - 77
  • [9] Virtual characterisation of porcupine quills using X-ray micro-CT
    Tee, Yun Lu
    Black, Jay R.
    Phuong Tran
    VIRTUAL AND PHYSICAL PROTOTYPING, 2023, 18 (01)
  • [10] Multiscale characterization of glass wools using X-ray micro-CT
    Meftah, Redouane
    Berger, Sylvain
    Jacqus, Gary
    Laluet, Jean-Yves
    Cnudde, Veerle
    MATERIALS CHARACTERIZATION, 2019, 156