Bridging external fixation versus non-bridging external fixation for unstable distal radius fractures: A systematic review and meta-analysis

被引:9
|
作者
Gu, Wan-Li [1 ]
Wang, Jun [1 ]
Li, Dong-Qing [2 ]
Gong, Ming-Zhi [1 ]
Chen, Peng [1 ]
Li, Zhong-Yi [3 ]
Yang, Li-Feng [3 ]
Liu, Wei [3 ]
Zhou, Ye [3 ]
机构
[1] Shandong Univ, Hosp 2, Dept Trauma Orthoped, 247 Beiyuan St, Jinan 250033, Shandong, Peoples R China
[2] Shandong Univ, Hosp 2, Dept Operating Theater, Jinan 250033, Peoples R China
[3] Shenyang Med Coll, Cent Hosp, Dept Orthoped, Shenyang 110000, Peoples R China
关键词
INTRAARTICULAR FRACTURES; SURGICAL-TREATMENT; TRIAL; INFECTION; REDUCTION; WRIST; PINS;
D O I
10.1016/j.jos.2015.10.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: A systematic review and meta-analysis was conducted to compare the relative effectiveness of bridging external fixation and non-bridging external fixation for distal radius fractures treatment. Method: Relevant literature were comprehensively searched using the PubMed, Springer Link, Karger Medical and Scientific Publishers, Chinese Biomedical Database (CBM) and Chinese National Knowledge Infrastructure (CNKI) databases without any language restrictions. STATA Version 12.0 software and Comprehensive Meta-analysis 2.0 were applied. Results: A total of 905 patients with distal radius fracture from six eligible cohort studies were selected for statistical analysis. Our meta-analysis results indicate that the non-bridging cases had a higher risk of pin track infection, rupture of the extensor pollicis longus and nerve injury than the bridging cases. Subgroup analysis stratified by country indicated non-bridging patients showed evidence of an increased risk of pin track infection and higher risk of rupture of the extensor pollicis longus compared with the patients treated with bridging external fixation in the UK population. The follow-up results showed flexion degree of patients treated with non-bridging external fixation was slightly better than that of patients treated with bridging external fixation (P < 0.05). Conclusion: There is evidence in our systematic review and meta-analysis to support that bridging external fixation can reduce the incidence of pin tract infections and nerve injury compared to non bridging external fixation, but have no significant difference in other complications and the recovery of wrist joint function. Bridging external fixation could therefore be a better choice in patients with distal radius fractures. (C) 2015 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [21] Dynamic versus static external fixation for unstable distal radius fractures: An up-to-date meta-analysis
    Cui, Zhuang
    Yu, Bin
    Hu, Yanjun
    Lin, Qingrong
    Wang, Bowei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 1006 - 1013
  • [22] Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius
    Gradl, Georg
    Gradl, Gertraud
    Wendt, Martina
    Mittlmeier, Thomas
    Kundt, Guenther
    Jupiter, Jesse B.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (05) : 595 - 602
  • [23] Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
    Qi Gou
    Xiong Xiong
    Dan Cao
    Yuanliang He
    Xu Li
    BMC Musculoskeletal Disorders, 22
  • [24] TREATMENT OF UNSTABLE FRACTURES OF THE DISTAL RADIUS BY EXTERNAL FIXATION
    VAUGHAN, PA
    LUI, SM
    HARRINGTON, IJ
    MAISTRELLI, GL
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (03): : 385 - 389
  • [25] Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
    Gou, Qi
    Xiong, Xiong
    Cao, Dan
    He, Yuanliang
    Li, Xu
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [26] AUGMENTED EXTERNAL FIXATION OF UNSTABLE DISTAL RADIUS FRACTURES
    SEITZ, WH
    FROIMSON, AI
    LEB, R
    SHAPIRO, JD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (06): : 1010 - 1016
  • [27] Volar locking plate versus external fixation in distal radius fractures: A meta-analysis
    Maccagnano, Giuseppe
    Noia, Giovanni
    Vicenti, Giovanni
    Baglioni, Marco
    Masciale, Maria Rosa
    Cassano, Giuseppe Danilo
    Vitiello, Raffaele
    Moretti, Biagio
    Pesce, Vito
    ORTHOPEDIC REVIEWS, 2021, 13 (01)
  • [28] Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius
    Georg Gradl
    Gertraud Gradl
    Martina Wendt
    Thomas Mittlmeier
    Guenther Kundt
    Jesse B. Jupiter
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 595 - 602
  • [29] Re: External fixation of unstable pelvic fractures: a systematic review and meta-analysis
    Stewart, Rebecca G.
    Kieser, David C.
    Hammer, Niels
    ANZ JOURNAL OF SURGERY, 2019, 89 (06) : 787 - 787
  • [30] Displaced Intra-Articular Fractures of the Distal Radius: Open Reduction With Internal Fixation Versus Bridging External Fixation
    Fakoor, Mohammad
    Fakoor, Morteza
    Mohammadhoseini, Payam
    TRAUMA MONTHLY, 2015, 20 (03)